My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5611 COLBY AVE 2024-02-09
>
Address Records
>
COLBY AVE
>
5611
>
5611 COLBY AVE 2024-02-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2024 1:53:40 PM
Creation date
12/15/2023 10:20:13 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
5611
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
135
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Two-Hole Strap-designed to support CPVC piping systems when attached to <br /> a flat, horizontal surface with the screw-type fasteners in the vertical position. <br /> In addition, the two-hole strap is designed to support CPVC piping systems <br /> when attached to a flat, vertical surface with one mounting tab in the vertical <br /> position and the screw-type fasteners in the horizontal position.The two-hole <br /> strap can be used as a piping system guide when the system lies on tap of a <br /> beam, and the beam supports the system's weight. <br /> Two-Hole 90°Side Mount Strap-designed to support CPVC piping systems <br /> when attached to a horizontal beam with the screw-type fasteners in the <br /> horizontal position and the pipe hanging below the beam. The fastener's <br /> mounting edges are designed to allow the screws to be installed horizontally. <br /> This is a benefit when overhead clearance is limited. In addition,the 900 side <br /> mount strap can be used in a restrainer fashion when it is attached to the top <br /> of a beam, and the system lies on top of the beam. <br /> flis r Supports <br /> Risers must be supported by pipe clamps or by hangers located on the <br /> horizontal connection close to the riser. Only Listed hangers and clamps <br /> can be used. Vertical lines must be supported at intervals to avoid placing <br /> excessive load on a fitting at the lower end. This can be done by using riser <br /> clamps or double-bolt pipe clamps listed for this service. <br /> Hangers and supports must not compress, distort, cut, or abrade the piping, <br /> and they must allow free movement of the pipe for thermal expansion and <br /> contraction. DO NOT use riser clamps that squeeze the pipe and depend on <br /> compression of the pipe to support the weight. <br /> Maintain vertical piping in straight alignment with supports at each floor level or <br /> 10-foot intervals,whichever is less. CPVC risers in vertical shafts or buildings <br /> with ceilings over 25 feet must be aligned straight and supported at each floor <br /> level or 10-foot intervals,whichever is less. <br /> G-3-1010 O 2010 SpearsO Manufacturing Company Page 41 <br />
The URL can be used to link to this page
Your browser does not support the video tag.