Laserfiche WebLink
GENERAL YES NO <br /> Bathroom doors are easily and quickly open a blefrom the outside when locked 0 0 <br /> Carbon Monoxide alarms are installed as required in R315on each I evel of the home. 0 0 <br /> Smoke a I arms are installed on a I I I evels of the dwel I i ng,in each residents leeping room,outside each separate <br /> s I eeping area in the immediate vicinity of sleeping rooms(R314). 0 0 <br /> Smoke and Carbon Monoxide alarms are installed ins uchamanners othatthe audiblewarningmaybeheard inaI1 0 0 <br /> parts of the dwel ling u pon activation of a singled evice. <br /> Access road and water supply meet IocaIfire jurisdictional requirements. 0 0 <br /> R325.4 Operable parts of door handles,pulls,latches,locks and other devices installed in AFH shall be operable with one hand <br /> and sha I I not require tight grasping,pinching or twisting of the wrist(I ever-type). 0 0 <br /> Pocket doors sha I I have graspable hardware a vailablewhen in the closed or open position. 0 0 <br /> R311.8 Ramps YES NO <br /> Inside Ramp N/A 0 0 0 <br /> R311.8.1 Maximum Slope one unit vertical in twelve units horizontal(8.3%slope).(Exception R311.8.1 Not allowed in AFH) <br /> R311.8.2 Landing Requirements:min.3X3 foot landingattop/bottom,where doors open onto ramps,and where rampchanges <br /> directions. 0 0 <br /> R325.9.1 Handrails required on both sides of ramp in accordancewith R311.8.3.1—R311.8.3.3. 0 0 <br /> Outside Ramp I N/A[3 1 YES NO <br /> R311.8.1 Maximum Slope one unit vertical in twelve units horizontal(8.3%slope).(Exception R311.8.1 Not allowed in AFH) <br /> R311.8.2 Landing Requirements:min.3X3 foot landingattop/bottom,where doorsopen onto ramps,and where rampchanges <br /> directions. <br /> R325.9.1 Handrails required on both sides of ramp in accordancewith R311.8.3.1—R311.8.3.3. 0 0 <br /> Guards below are depicted vertically as an example only.All Ramps must have Guards 0 0 <br /> Handrail both sides <br /> Less than 4" 34"-38" <br /> Guard <br /> 36"min <br /> 3'x3'min <br /> landing <br /> 3'x3'min <br /> landing T7 <br /> 3' One unit vertical in twelve units horizontal 3' <br /> minimum is an 8.3%slope all along surface of the ramp. minimum <br /> R311.2 Means of Egress YES NO <br /> R311.2 Door must be side-hinged with min.width of 32 inches between face of door and stop.Height not less than 78 inches. 0 0 <br /> R325.4 Operable parts of door handles,pulls,latches,locks and other devices installed in AFH shall be operable with one hand <br /> and shall not require tight grasping,pinching ortwistingofthe wrist(lever-type). Q Q <br /> R325.4 Required exit door hardware shall unlock insideand outside mechanisms when exitingthe building allowing re-entry 0 0 <br /> without use of key,tool or special knowledge. <br /> R311.7 Stairways I N/A YES NO <br /> R311.7.5.1 Riser Height:Max riser height shall be 7% inches(8 inches in structures built prior to July 1,2004) 0 0 <br /> R311.7.5.2 Tread Depth:Min.tread depth shall be in 10 inches(9 inches in structures builtpriortoJuly 1,2004) 13 13 <br /> R325.10.1 Handrails for Treads and Risers shall be installed on both sides of treads and risers numberingfrom one riser to m ultiple <br /> risers.Handrails shall be installed in accordance with R311.7.8.1—R311.7.8.4 <br /> Effective:2013 July 01 <br /> Updated:2017 February <br />