My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5611 COLBY AVE 2024-02-09
>
Address Records
>
COLBY AVE
>
5611
>
5611 COLBY AVE 2024-02-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2024 1:53:40 PM
Creation date
12/15/2023 10:20:13 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
5611
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
135
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
BALANGUE ADDITION April 6, 2023 SDA Job# 9328 8 <br /> ROOF MARRIAGE WALL A15-WSW ISEGMENTEDWALL <br /> Floor Info Tributary Area(ROOF) Tributary Area(ROOF) <br /> ROOF I Floor Level,e.g.Roof,4TH,3RD,2ND1.0 tributary width 1.0 tributary area <br /> Lt-Rt Load Direction,e.g.Left-Right,Front-Rear 2.0 total width 2.0 total area <br /> (For Left Wall,Use Front-Rear Load Direction) Tributary Area(NA) Tributary Area(NA) <br /> CDX Sheathing type(T4.3A of SDPWS-2015) tributary width tributary area <br /> total width total area <br /> ROOF Resisting Dead Load Tributary Area(NA) z Tributary Area(NA) <br /> Shearwall Segment Lengths: Adj.Total Length= 23.0 ft o tributary width ¢ tributary area <br /> 23.0 ft total width total area <br /> o Tributary Area(NA) Tributary Area(NA) <br /> FV(ROOF)= 11494 Ib 10802 Ib Z tributary width w tributary area <br /> EV()= 0 Ib 0 Ib 3 total width Itotal area <br /> EV()= 0 Ib 0 Ib <br /> EV()= 0 Ib 0 Ib Height of Shearwall= 8.0 ft Weight of Shearwall= 10.0 lbs <br /> E(Wind)= 11,494 Ib E(Smc)= 10,802 Ib Length of Shearwall= 23.0 ft Tributary width for dead load= 15.0 ft <br /> ULT.v= 250 PLF ULT.v= 235 PLF Aspect Ratio OK Length of adjoining wall= 2.0 ft <br /> 3,448 Ib 3,781 Ib R= 6.5 <br /> ASD SHEAR WALL DESIGN PER:AF&PA SDPWS-2015 LRFD Holdown Design? No no= 2.5 <br /> ULT.WIND CAPACITY:1.4 x 0.93 x 460 PLF/(2 x 0.6)=499 PLF Ductile Anchor Design? No Block Shear Wall <br /> ULT.SEISMIC CAPACITY:1 x 0.93 x 460 PLF/(2 x 0.7)=305 PLF USE A, <br /> Holdown Above:1 NO FLOOR ABOVE Seismic controls shearwall design <br /> ASD C.TOTAL= (floor above)+(this floor)= 0 lbs + 1912 lbs = 1912 lbs Seismic controls-C3(ASD eq.8): <br /> ASD T.TOTAL w/o 00= (floor above)+(this floor)= 0 lbs + -558 lbs = -558 lbs Seismic controls-T2(ASD eq.10): <br /> Unfactored C.WL=1999 lbs Unfactored T.WL=3113 lbs NO HOLDOWNS REQUIRED I <br /> Unfactored C.EQ=1879 lbs Unfactored T.EQ=1879 lbs FOUNDATION/INTERIOR WALLS: OK <br /> Unfactored C.DL= 4118 lbs Unfactored C.LL/SL=5063 lbs <br /> ROOF-REAR ADDITION FAMILY ROOM A15-WSW SEGMENTED WALL <br /> Floor Info Tributary Area(ROOF) Tributary Area(ROOF) <br /> ROOF Floor Level,e.g.Roof,4TH,3RD,2ND 12.3 tributary width 741.0 tributary area <br /> Lt-Rt Load Direction,e.g.Left-Right,Front-Rear 80.5 total width 3734.0 total area <br /> (For Left Wall,Use Front-Rear Load Direction) Tributary Area(NA) Tributary Area(NA) <br /> CDX Sheathing type(T4.3A of SDPWS-2015) tributary widthtributary area <br /> total width total area <br /> ROOF Resisting Dead Load Tributary Area(NA) z Tributary Area(NA) <br /> Shearwall Segment Lengths: Adj.Total Length= 8.8 ft K tributary width a tributary area <br /> 2.3 ft 3.5 ft 4.4 ft ao total width total area <br /> o Tributary Area(NA) Tributary Area(NA) <br /> EV(ROOF)= 11494 Ib 10802 Ib Z tributary width w tributary area <br /> EV()= 0 Ib 0 Ib Itotal width total area <br /> EV()= 0 Ib 0 Ib <br /> EV()= 0 Ib 0 Ib Height of Shearwall= 8.0 ft Weight of Shearwall= 10.0 lbs <br /> E(Wind)= 11,494 Ib E(Smc)= 10,802 Ib Length of Shearwall= 2.3 ft Tributary width for dead load= 2.0 ft <br /> ULT.v= 198 PLF ULT.v= 243 PLF Aspect Ratio OK Length of adjoining wall= 2.0 ft <br /> R= 6.5 <br /> ASD SHEAR WALL DESIGN PER:AF&PA SDPWS-2015 LRFD,Holdown Design? Yes On= 2.5 <br /> ULT.WIND CAPACITY:1.4 x 0.93 x 460 PLF/(2 x 0.6)=499 PLF Ductile Anchor Design? Yes Block Shear Wall <br /> ULT.SEISMIC CAPACITY:1 x 0.93 x 460 PLF/(2 x 0.7)=305 PLF USE" <br /> Holdown Above:1 NO FLOOR ABOVE Seismic controls shearwall design <br /> ASD C.TOTAL= (floor above)+(this floor)= 0 lbs + 1412 lbs = 1412 lbs Seismic controls-C3(ASD eq.8): <br /> ASD T.TOTAL w/o 00= (floor above)+(this floor)= 0 lbs + 1203 lbs = 1203 lbs Seismic controls-T2(ASD eq.10): <br /> LRFD T.TOTAL w/o 00= (floor above)+(this floor)= 0 lbs + 1703 lbs = 1703 lbs Seismic controls-T2 LRFD eq.7): <br /> Unfactored C.WL=1587 lbs Unfactored T.WL=1621 lbs SIMPSON DESIGNED HOLDOWN: <br /> Unfactored C.EQ=1944 lbs Unfactored T.EQ=1944 lbs FOUNDATION/INTERIOR WALLS: JHMI <br /> Unfactored C.DL= 348 lbs Unfactored C.LL/SL=158 lbs <br />
The URL can be used to link to this page
Your browser does not support the video tag.