5611 COLBY AVE 2024-02-09
>
Address Records
>
COLBY AVE
>
5611
>
5611 COLBY AVE 2024-02-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2024 1:53:40 PM
Creation date
12/15/2023 10:20:13 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
5611
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
135
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
BALANGUE ADDITION April 6, 2023 SDA Job# 9328 9 <br /> ROOF-REAR ADDITION BED G I A15-WSW ISEGMENTEDWALL <br /> Floor Info Tributary Area(ROOF) Tributary Area(ROOF) <br /> ROOF I Floor Level,e.g.Roof,4TH,3RD,2ND 12.3 tributary width 175.5 tributary area <br /> Lt-Rt Load Direction,e.g.Left-Right,Front-Rear 80.5 total width 3734.0 total area <br /> (For Left Wall,Use Front-Rear Load Direction) Tributary Area(NA) Tributary Area(NA) <br /> CDX Sheathing type(T4.3A of SDPWS-2015) tributary width tributary area <br /> total width total area <br /> ROOF Resisting Dead Load Tributary Area(NA) z Tributary Area(NA) <br /> Shearwall Segment Lengths: Adj.Total Length= 17.0 ft o tributary width Q tributary area <br /> 17.0 ft total width total area <br /> o Tributary Area(NA) Tributary Area(NA) <br /> EV(ROOF)= 11494 Ib 10802 Ib Z tributary width w tributary area <br /> EV()= 0 Ib 0 Ib 3 total width Itotal area <br /> EV()= 0 Ib 0 Ib <br /> EV()= 0 Ib 0 Ib Height of Shearwall= 8.0 ft Weight of Shearwall= 10.0 lbs <br /> E(Wind)= 11,494 Ib E(Smc)= 10,802 Ib Length of Shearwall= 17.0 ft Tributary width for dead load= 2.0 ft <br /> ULT.V= 103 PLF ULT.V= 30 PLF Aspect Ratio OK Length of adjoining wall= 2.0 ft <br /> R= 6.5 <br /> ASD SHEAR WALL DESIGN PER:AF&PA SDPWS-2015 LRFD Holdown Design? No 00= 2.5 <br /> ULT.WIND CAPACITY:1.4 x 0.93 x 460 PLF/(2 x 0.6)=499 PLF Ductile Anchor Design? No Block Shear Wall <br /> ULT.SEISMIC CAPACITY:1 x 0.93 x 460 PLF/(2 x 0.7)=305 PLF USE A, <br /> Holdown Above:1 NO FLOOR ABOVE Wind controls shearwall design <br /> ASD C.TOTAL= (floor above)+(this floor)= 0 lbs + 496 lbs = 496 lbs Wind controls-C1(ASD eq,5): <br /> ASD T.TOTAL w/o 00= (floor above)+(this floor)= 0 lbs + -128 lbs = -128 lbs Wind controls-T1(ASD eq.7): <br /> Unfactored C.WL=826 lbs Unfactored T.WL=942 lbs NO HOLDOWNS REQUIRED I <br /> Unfactored C.EQ=239 lbs Unfactored T.EQ=239 lbs FOUNDATION/INTERIOR WALLS: OK <br /> Unfactored C.DL= 1155 lbs Unfactored C.LL/SL=525 lbs <br /> ROOF-LEFT I A15-WSW ISEGMENTEDWALL <br /> Floor Info Tributary Area(ROOF) Tributary Area(ROOF) <br /> ROOF I Floor Level,e.g.Roof,4TH,3RD,2ND 1.0 tributary width 351.0 tributary area <br /> Ft-Rr Load Direction,e.g.Left-Right,Front-Rear 3.0 total width 3734.0 total area <br /> (For Left Wall,Use Front-Rear Load Direction) Tributary Area(NA) Tributary Area(NA) <br /> CDX Sheathing type(T4.3A of SDPWS-2015) tributary width tributary area <br /> total width total area <br /> ROOF Resisting Dead Load Tributary Area(NA) z Tributary Area(NA) <br /> Shearwall Segment Lengths: Adj.Total Length= 9.1ft K tributary width ¢ tributary area <br /> 6.0 ft 3.5 ft ao total width O total area <br /> o Tributary Area(NA) Tributary Area(NA) <br /> EV(ROOF)= 8267 Ib 10802 Ib Z tributary width w tributary area <br /> EV()= 0 Ib 0 Ib 3 total width Itotal area <br /> EV()= 0 Ib 0 Ib <br /> EV()= 0 Ib 0 Ib Height of Shearwall= 8.0 ft Weight of Shearwall= 10.0 lbs <br /> 3 F(Wind)= 8,267 Ib E(Smc)= 10,802 Ib Length of Shearwall= 3.5 ft Tributary width for dead load= 13.0 ft <br /> ULT.V= 304 PLF ULT.V= 112 PLF Aspect Ratio OK Length of adjoining wall= 2.0 ft <br /> R= 6.5 <br /> ASD SHEAR WALL DESIGN PER:AF&PA SDPWS-2015 LRFD Holdown Design? No 40= 2.5 <br /> ULT.WIND CAPACITY:1.4 x 0.93 x 460 PLF/(2 x 0.6)=499 PLF Ductile Anchor Design? No Block Shear Wall <br /> ULT.SEISMIC CAPACITY:1 x 0.93 x 460 PLF/(2 x 0.7)=305 PLF USE 1 <br /> Holdown Above: NO FLOOR ABOVE Wind controls shearwall design <br /> ASD C.TOTAL= (floor above)+(this floor)= 0 lbs + 1460 lbs = 1460 lbs Wind controls-C1(ASD eq,5): <br /> ASD T.TOTAL w/o 00= (floor above)+(this floor)= 0 lbs + 1002 lbs = 1002 lbs Wind controls-T1(ASD eq.7): <br /> Unfactored C.WL=2433 lbs Unfactored T.WL=2701 lbs SIMPSON DESIGNED HOLDOWN:I <br /> Unfactored C.EQ=896 lbs Unfactored T.EQ=896 lbs FOUNDATION/INTERIOR WALLS: 11 LSTHD8/RJ <br /> Unfactored C.DL= 1031 lbs Unfactored C.LL/SL=1219 lbs <br />
The URL can be used to link to this page
Your browser does not support the video tag.