My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6930 CARSON RD 2024-02-09
>
Address Records
>
CARSON RD
>
6930
>
6930 CARSON RD 2024-02-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2024 8:08:27 AM
Creation date
12/15/2023 11:19:36 AM
Metadata
Fields
Template:
Address Document
Street Name
CARSON RD
Street Number
6930
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
48
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• • <br /> 2018 Washington State Energy Code—Residential <br /> Prescriptive Energy Code Compliance for All Climate Zones in Washington <br /> Single Family-New&Additions(et( fire February 1, 1) . Vermin 1.0 <br /> These requirements apply to ail IRC building types,including detached one-and two-family <br /> dwellings and multiple single-family dwellings(townhouses). <br /> Project information _-- _ Contact in formation <br /> 6930 Carson Drive .arry Thibeault <br /> Everett,WA 98203 25-209-7600 or rsalarry@hotmail.com <br /> Instructions:This single-family project will use the requirements of the Prescriptive Path below and <br /> incorporate the minimum values listed.Based on the size of the structure,the appropriate number of <br /> additional credits are checked as chosen by the permit applicant. <br /> Provide all information from the following tables as . ilding - F . n wings:Table R402.1-Insulation and <br /> AlaFenestration Requirements by Component,Tabl- ,406. on Credits and 406.3-Energy Credits. <br /> ,dr <br /> Authorized Representative � ffi1®2!� Date ; Cr 7 J.1 <br /> I Clime _Zo es(Table R402.1.1) <br /> R aloe a U-Factor a <br /> Fenestration U-Factor b n/a 0.30 <br /> Skylight U-Factor b n/a 0.50 <br /> Glazed Fenestration SHGC b, n/a n/a <br /> Ceilinge 49 i 0.026 <br /> Wood Frame Wall gm 21 int 0.056 <br /> Floor 30 0.029 <br /> cm Grade Wall� _..._ 10/15/21 int+TB 0.042 <br /> Slab df R-Value&Depth 10,2 ft n/a. <br /> R-values are minimums.U-factors and SHGC are maximums.When insulation is installed in a cavity that is less <br /> a than the label or design thickness of the insulation,the compressed R value of the insulation from Appendix <br /> Table A101.4 shall not be less than the R-value specified in the table. <br /> b The fenestration U-factor column excludes skylights. <br /> "10/15/21+5TB"means R-10 continuous insulation on the exterior of the wall,or R-15 continuous insulation on <br /> the interior of the wall,or R-21 cavity insulation plus a thermal break between the slab and the basement wall at <br /> c the interior of the basement wall."10/15/21+5TB"shall be permitted to be met with R-13 cavity insulation on <br /> the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall."5TB" <br /> means R-5 thermal break between floor slab and basement wall. <br /> d R-10 continuous insulation is required under heated slab on grade floors.See Section R402.2.9.1. <br /> e ! <br /> For single rafter-or joist-vaulted ceilings,the insulation may be reduced to R-38 if the full insulation depth <br /> extends over the top plate of the exterior wall. <br /> i R-7.5 continuous insulation installed over an existing slab is deemed to be equivalent to the required perimeter <br /> f Islab insulation when applied to existing slabs complying with Section R503.1.1.If foam plastic is used,it shall <br /> meet the requirements for thermal barriers protecting foam plastics. <br /> For log structures developed in compliance with Standard ICC 400,log walls shall meet the requirements for <br /> g 'climate zone 5 of ICC 400. <br /> Int.(intermediate framing)denotes framing and insulation as described in Section A103.2.2 including standard <br /> h I framing 16 inches on center,78%of the wall cavity insulated and headers insulated with a minimum of R-10 <br /> insulation. SeZIE7-) <br /> OCT 12 2021 ii <br /> CITY OF EVERETT <br /> IIILE©Zllva <br /> Permit Services JUN O 9 � <br /> Prescriptive Path—Single Family 2018 Washington State Energy Code-R CIT i U <br /> Y• Y <br /> OF EVERETT` <br /> Permit ServiCes I I 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.