My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2110 HEWITT AVE 2024-02-12
>
Address Records
>
HEWITT AVE
>
2110
>
2110 HEWITT AVE 2024-02-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/12/2024 8:35:54 AM
Creation date
12/15/2023 11:49:55 AM
Metadata
Fields
Template:
Address Document
Street Name
HEWITT AVE
Street Number
2110
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
117
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HOWIE BARGREEN I May 10, 2022 I SDA Job# 7673 I 5 <br /> IRREGULARITY: Increase in force due to irregularities for seismic design categories D-F(per ASCE7-16,§12.3.3.4): <br /> No ..No seismic load change Affected Levels: <br /> Out-of-plane offset with discontinuity,including out-of-plane offset of at least one vertical elements(T12.3-1,Ty e 4) <br /> No :.No seismic load change Affected Levels: <br /> One or two-family dwelling of light frame construction: No Oo= <br /> FLEXIBLE DIAPHRAGM DESIGN (ASD) <br /> EV(Roof)= <br /> %of load transfer= 100% (Percentage of load transferred through diaphragm) <br /> Total diaphragm length= 100.0 ft <br /> Sub-diaphragm length= 100.0 ft 0.6 x IV(Roof)= 9,143 lbs FACTORED WIND(FRONT-REAR) ---> Location @ 253 PLF x S.G.=0 ft. <br /> Diaphragm width= 53.0 ft 0.7 x EV(Roof)= 41,965 lbs FACTORED SEISMIC/rho ---> Location @ 240 PLF x S.G.=24 ft. <br /> Aspect Ratio= 1.8867925 <br /> ASDxFV(FLOOR) [9144 lbs,41965 lbs] <br /> (2)(width)(S.G.) 2 x 53 ft.x 0.93 =[WIND=93 PLF,SEISMIC=426 PLF] *Seismic Governs! <br /> 2015 SDPWS T4.2A&T4.2C *NOTE:SEISMIC MAY GOVERN OVER WIND DUE TO HIGHER WIND CAPACITY <br /> FROM 0-24FT.USE:15/32"SHEATHING WITH 2x HEM-FIR FRAMING;FASTEN AT PANEL EDGES WITH 8d @ 6"0/C;FASTEN AT BOUNDARY <br /> EDGE WITH 8d @ 4"0/C;ELSEWHERE FASTEN ALL EDGES WITH 8d @ 6"O/C <br /> EV(2nd Floor)= <br /> %of load transfer= 10% (Percentage of load transferred through diaphragm) <br /> Total diaphragm length= 100.0 ft <br /> Sub-diaphragm length= 100.0 ft #VALUE! #VALUE! #VALUE! #VALUEI ft. <br /> Diaphragm width= 53.0 ft 0.7 x EV(2nd Floor)= -1 lbs FACTORED SEISMIC/rho ---> Location @ 240 PLF x S.G.=0 ft. <br /> Aspect Ratio= 1.8867925 <br /> v_ ASDxFV(FLOOR) _ #VALUE! #VALUE! #VALUE! <br /> (2)(width)(S.G.) 2 x 53 ft.x 0.93 <br /> 2015 SDPWS T4.2A&T4.2C `NOTE:SEISMIC MAY GOVERN OVER WIND DUE TO HIGHER WIND CAPACITY <br /> SEE 2015 SDPWS T4.2B FOR HIGH STRENGTH BLOCKING <br />
The URL can be used to link to this page
Your browser does not support the video tag.