Laserfiche WebLink
HOWIE BARGREEN May 10, 2022 SDA Job# 7673 8 <br /> FRONT FRAME I B4-OSCBF ISEE FRAME&CONNECTION CALCULATIONS <br /> Floor Info Tributary Area(ROOF) Tributary Area(ROOF) <br /> ROOF Floor Level,e.g.Roof,4TH,3RD,2ND 1.0 tributary width 1.0 tributary area <br /> Ft-Rr Load Direction,e.g.Left-Right,Front-Rear 2.0 total width 2.0 total area <br /> (For Left Wall,Use Front-Rear Load Direction) Tributary Area(2ND) Tributary Area(2ND) <br /> tributary width tributary area <br /> total width total area <br /> ROOF Resisting Dead Load Tributary Area(NA) 2 Tributary Area(NA) <br /> #OF FRAMES 1.00 o tributary width a tributary area <br /> I <br /> ao total width 9 total area <br /> o Tributary Area(NA) Tributary Area(NA) <br /> EV(ROOF)= 15239 lb 77935 lb Z tributary width w tributary area <br /> IV()= 0 lb 0 lb total width " total area <br /> EV O= O lb 0 1b <br /> EV()= 01b 0 1b <br /> I(Wind)= 15,239 lb I(Smc)= 77,935 lb <br /> ULT.V= 7,620 lb ULT.V= 38,967 lb<-rho=1.3,00=0 <br /> 29,975 lb<-rho=1.0,00=0 R= 3.3 <br /> Do= 2.0 <br /> SINGLE'X'BRACE: <br /> TENSION&COMPRESSION w/OMEGA NOT=97,418#PER BASEPLATE <br /> SHEAR w/OMEGA NOT=38,967#PER BASEPLATE <br /> L — <br /> CLEARSTORY WALL ABOVE€STEEL BEAM I Al 5-WSW (SEGMENTED WALL <br /> Floor Info Tributary Area(ROOF) Tributary Area(ROOF) <br /> ROOF Floor Level,e.g.Roof,4TH,3RD,2ND 1.0 tributary width 1.0 tributary area <br /> Ft-Rr Load Direction,e.g.Left-Right,Front-Rear 2.0 total width 2.0 total area <br /> (For Left Wall,Use Front-Rear Load Direction) Tributary Area(2ND) Tributary Area(2ND) <br /> CDX Sheathing type(T4.3A of SDPWS-2015) tributary width tributary area <br /> total width total area <br /> ROOF Resisting Dead Load Tributary Area(NA) 2 Tributary Area(NA) <br /> Shearwall Segment Lengths: Adj.Total Length= 44.0 ft o tributary width as tributary area <br /> 26.0 ft I 18.0 ft I ao total width total area <br /> o Tributary Area(NA) Tributary Area(NA) <br /> EV(ROOF)= 15239 lb 51957 lb z tributary width vr LT, <br /> tributary area <br /> IV()= 0 lb 0 lb total width rn total area <br /> EV()= 0 1b 0 1b <br /> IV()= 0 lb 0 lb Height of Shearwall= 1.3 ft Weight of Shearwall= 10.0 lbs <br /> I(Wind)= 15,239 lb I(Smc)= 51,957 lb Length of Shearwall= 18.0 ft Tributary width for dead load= 2.0 ft <br /> ULT.V= 173 PLF ULT.V= 590 PLF Aspect Ratio OK Length of adjoining wall= 2.0 ft <br /> 104 lb 413 lb R= 6.5 <br /> ASD SHEAR WALL DESIGN PER:AF&PA SDPWS-2015 LRFD Holdown Design? No 40= 2.5 <br /> ULT.WIND CAPACITY:1.4 x 0.93 x 1020 PLF/(2 x 0.6)=1106 PLF Ductile Anchor Design? No Block Shear Wall <br /> ULT.SEISMIC CAPACITY:1 x 0.93 x 1020 PLF/(2 x 0.7)=677 PLF USE <br /> NO FLOOR ABOVE Seismic controls shearwall design <br /> ASD C.TOTAL= (floor above)+(this floor)= 0 lbs + 604 lbs = 604 lbs Seismic controls-C3(ASD eq.8): <br /> ASD T.TOTAL w/o DO= (floor above)+(this floor)= 0 lbs + 224 lbs = 224 lbs Seismic controls-T2(ASD eq.10): <br /> Unfactored C.WL=216 lbs Unfactored T.WL=495 lbs NO HOLDOWNS REQUIRED OK <br /> Unfactored C.EQ=738 lbs Unfactored T.EQ=738 lbs FOUNDATION/INTERIOR WALLS: OK <br /> Unfactored C.DL= 633 lbs Unfactored C.LL/SL=550 lbs <br />