2020 LAKE HEIGHTS DR WATERFORD PLACE APTS 2023-12-29
>
Address Records
>
LAKE HEIGHTS DR
>
2020
>
WATERFORD PLACE APTS
>
2020 LAKE HEIGHTS DR WATERFORD PLACE APTS 2023-12-29
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/29/2023 2:46:33 PM
Creation date
12/18/2023 8:18:47 AM
Metadata
Fields
Template:
Address Document
Street Name
LAKE HEIGHTS DR
Street Number
2020
Tenant Name
WATERFORD PLACE APTS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(-L3) Smoke Detector Specifications <br />Smoke detector shall be a System Sensor i3 Series model number listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems.The <br />detector shall be a photoelectric type (Model 2W-B, 4W-B) or a combination photoelectric/thermal (Model 2WT-B, 4WT-B) with thermal sensor rated at 1357 <br />(57.2°C).The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal, single -gang, and 4-inch square back boxes with a plaster <br />ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws. The detector shall allow pre -wiring of the <br />base and the head shall be a plug-in type. The detector shall have a nominal sensitivity of 2.5 percent -per -foot nominal as measured in the UL smoke box. The <br />detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms. The detector shall provide dual - <br />color LED indication that blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2WT-B, 4WT-B) conditions. When used <br />in conjunction with the 2W-MOD2 module, 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel <br />and shall provide a loop testing capability to verify the circuit without testing each detector individually. <br />Operating Voltage Nominal: 12/24V non -polarized <br />Minimum: 8.5 V <br />Maximum: 35 V <br />Maximum Ripple Voltage <br />30% peak to peak of applied voltage <br />Standby Current <br />2-wire: 50 NA maximum average; 4-wire: 50 NA maximum average <br />Maximum Alarm Current <br />2-wire: 130 mA limited by control panel; 4-wire: 20 mA @12 V, 23 mA @ 24 V <br />Peak Standby Current <br />2-wire: 100 uA; 4-wire: n/a <br />Alarm Contact Ratings <br />2-wire: n/a; 4-wire: 0.5 A @ 30 V AC/DC <br />Physical Specifications <br />Dimensions (including base) <br />5.3 inches (127 mm) diameter; 2.0 inches (51 mm) height <br />Weight <br />6.3 oz (178 g) <br />Operating Temperature Range <br />2W-B and 4W-B: 32°F to 1207 (0°C to 49°C); 2WT-B and 4WT-B: 327 to 1007 (0°C to 37.8°C) <br />Operating Humidity Range <br />0 to 95% RH non -condensing <br />Thermal Sensor <br />1357 (57.2°C) fixed <br />Freeze Trouble <br />2WT-B and 4WT-B only:417 (5°C) <br />Sensitivity <br />2.50/o/ft nominal <br />Input Terminals <br />14 to 22 AWG <br />Mounting <br />LED Modes <br />3'/2-inch octagonal back box <br />4-inch octagonal back box <br />Single -gang back box <br />4-inch square back box with a plaster ring <br />Direct mount to ceiling <br />Power -Up Sequence for LED Indication <br />LED Mode Green LED <br />Red LED Condition Duration <br />Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds <br />Normal (standby) Blink every 5 seconds off <br />Out of sensitivity off <br />Blink every 5 seconds <br />Freeze trouble off <br />Blink every 10 seconds <br />Alarm off <br />Solid <br />Ordering Information <br />Model Thermal <br />2W-B No <br />Wiring Alarm Current <br />2-wire 130 mA max. limited by control panel <br />2WT-B Yes <br />2-wire 130 mA max. limited by control panel <br />4W-B No <br />4-wire 20 mA @ 12 V, 23 mA @ 24 V <br />4WT-B Yes <br />4-wire 20 mA @ 12 V, 23 mA @ 24 V <br />Accessories <br />2W-MOD2 2-wire loop test / maintenance module RT Removal / replacement tool <br />SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket, 6.6 inch (16.76 cm) diameter <br />f_ SY TE� <br />�/ <br />SENSOR <br />m2cha System Sensor. <br />3825 Ohio Avenue • St. Charles, L 60174 Product specifications subjec[to009 System Sensotice.Vsit rystemsensoccom for <br />Phone:800-SENSOR2•Fax:630-377-6495 urrentproductinformat5-03180i7-6/09latest version okhisdata sheet. <br />A06-0318-007.6/09•#2169 <br />