Laserfiche WebLink
LEGEND <br /> SEE SHEET EOA FOR SYMBOLS AND ABBREVIATIONS. <br /> 7 7.5 8 5 9 <br /> _ BLDG. 40-024 K GENERAL NOTES <br /> K' FOR SV24 SPRINKLER RISER MONITORING DEVICES, SEE <br /> 40-024-1E273 <br /> UTILITY TRENCH I <br /> N I T04K8 <br /> ILI T03K8 <br /> N I <br /> Li T02KB L <br /> UI <br /> I I tz <br /> w <br /> =Ln REFERENCE DRAWINGS <br /> of SV25-14 TAMPER T01K8 I z <br /> �I T01K7 1 1/2"C, 22/40 1"C, 4#14 I o <br /> 4#14 1L <br /> � � SV25-i6 TAMPER1:19:1 0 <br /> SV24- 7 1/2"C, 22/4C SV25-T4 1/2"C, SV25-�1/2"C, 2#16 TAMPE TYCO J-BOX 3/4 C, 16/10C 1/2"C, 2#14 TAMPER 22/4C TAMPER I o <br /> v vs — � vs VS <br /> IFD 3/4'C, 2#14 3/4"C, 4#14, 22/4C <br /> V! L <br /> 3/4"C, 4#12 1/2"C, 2#161"C, 4114, 22/10C <br /> 1"C, 8#14 UP TO FIRST FLOOR- <br /> 1—1/4-C, <br /> LOOR1-1/4"C, 8#14, 2#16, T01K7 FOR CONTINUATION SEE SHEET TNE268 CONSTRUCTION NOTES <br /> (2)22/4C UP TO FIRST FLOOR 1�CONNECT EXISTING DEVICE TO NEW BUILDING FIRE <br /> ALARM CONTROL PANEL. UTILIZE EXISTING <br /> INFRASTRUCTURE. PROVIDE ADDITIONAL CONDUIT AND <br /> B CONDUCTORS AS REQUIRED. <br /> PROVIDE REMOTE MONITOR MODULES FOR EACH DEVICE. <br /> INSTALL IN EXISTING J-BOX. UTILIZE J-BOX FOR <br /> CONNECTIONS BETWEEN FIELD DEVICES AND NEW <br /> BUILDING FIRE ALARM CONTROL PANEL. PROVIDE <br /> CONDUCTORS AS REQUIRED. <br /> PARTIAL PLAN VIEW N PROVIDE CONDUCTORS AND CONNECTION(S) BETWEEN <br /> NEW MONITOR <br /> SCALE: 1/8"=1'-0 MONITORING DEVOEULE AND EXISTING SPRINKLER <br /> 0.91 T T T T 1111 <br /> B(DG 40+24 j j K <br /> -E-0 'T-NE2-61 --2- NE263 T-N---- <br /> L <br /> I TNE265 1 TNE266 I TNE267 I TNE268 I TNE269 M <br /> 11 TNE270 1 TNE271 I TNE272 I TNE273 I TNE274 I g <br /> IlTNE275 ITNE276 ITNE277 ITNE278 1TNE279 jl m <br /> rTNE280TNE281 TNE282 jTNE283 'TNE284 ,_0 <br /> II I I I I I <br /> BLDG 40-26 • DENOTES PLANS <br /> KEY PLAN THIS ISETUDED IN <br /> SCALE: NONE N <br /> 8' 4' 0 4' 8' 16 <br /> SCALE: 1/8"=1'-0" <br /> RD BOX 1136 <br /> AUBURN,WA 98071 <br /> SEATRONICS 253-939-6060 <br /> FIRE PROTECTION SERVICES 'I 65 Ill 065-TNF263 <br /> DRAWN DTE <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ACCEPTABILITY RG A5.15.19 SUBTITLE CURRENT REVISION SYMBOL DATE <br /> A EVERETT FIRE PANEL REPLACEMENT BLDG 40-25 W2640474 SAZAN/ZO - THIS DESIGN AND/OR FIRE ALARM SYSTEM PLAN-TUNNEL 111065-0 B 5.15.19 <br /> SPECIFICATION IS APPROVED SHEET <br /> B EVERETT FIRE PANEL REPLACEMENT BLDG 40-24 SEA 5.15.19 ( BOE/A/6® APPROVED BY DEPT. DATE TITLE <br /> EVERETT FIRE PANEL REPLACEMENT BLDG 40-24 HECKED TN E263 <br /> APPROVED BUILDING 40-025 JOB NO. 111065 1 <br /> COMP NO. <br /> ELECTRICAL MASTER COL. K-L/7 9 EVERETT, WA.DWG NO. 40-025-TNE263 <br />