My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-24 2024-02-09
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-24
>
3003 W CASINO RD BLDG 40-24 2024-02-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2024 8:51:27 AM
Creation date
12/20/2023 6:48:30 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-24
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
5 2 2 5 3 LEGEND <br /> SEE SHEET EDA FOR SYMBOLS AND ABBREVIATIONS. <br /> 22 0-24 MAIN VESDA <br /> :15:11 ALM <br /> :15:12 TRBL � A <br /> 3/4"C, 4#12 <br /> FOR CONTINUATION, SEE SHEET 1E265 <br /> VESDA POS#1 1 C, 4#12 A <br /> DA POS#2 1"C, 4#12 1"C, 4#12 A <br /> s2 3/4"C, 4#12 3/4"C, 4#12 GENERAL NOTES <br /> A TAIR I ED>40-24 <br /> MONITORING POINTS: <br /> ELEV 20FA <br /> -3 ELEV 20 TRBL <br /> 1 <br /> x-x-x x x x x x� r2 2 ELEVATOR 20 �40-24 FACP MONITORING POINTS: <br /> ryiE506-19 _Q o FACP 3 40-24 MAIN VESDA FA <br /> Q ^ 40-24 MAN VESDA TRBL <br /> STORAGE WOMEN'S :1 :12 TRB 3. SEE 40-25-TNE260 FOR SPRINKLER RISER VALVES <br /> 4 TOILET ROOM M T I R I1:1 :13 SUP AND TAMPER SWITCHES <br /> 400 HZ O 1 :041 SV24-5 WF ® w <br /> Y <br /> GENERATOR 1 1 [PER 1:04:11 SV24-5 WF F HT E EVATOR z REFERENCE DRAWINGS <br /> 40-24 BUILDING A ( I o ®506-17 ELEVATOR 20 FIRE ALARM RISER <br /> FACP ANNUNCIATOR PRESS RE: f AND K-3 z DIAGRAMS <br /> GENERATOR A \ANITOR <br /> ORAGE <br /> E506-19 ELEVATOR 20 FIRE ALARM ENLARGED <br /> 1/2"C, 2 1/2"C, 4#16Q 2 PLANS <br /> 4#16 <br /> vs ow I! E528 SERIES VESDA SYSTEM DETAILS <br /> VS VS — — f\ <br /> _ — WF wF PD---D -- — <br /> BDG. 40-025 K' <br /> 1:03:12 SV24-1 WF ISO TAMPER 24-3 WF CONSTRUCTION NOTES <br /> ISO TAMPER 1:03:13 SV24-3 WF 1 CONSTRUCTION 1 I V I V J <br /> �PR <br /> PRESSURE 24-1 WF PRESSURE RISER. CONNECT RTO NEW BUILDING ING DEVICE IXFIRIE ALARM <br /> NG NKLER <br /> CONTROL PANEL. UTILIZE EXISTING INFRASTRUCTURE. <br /> PROVIDE ADDITIONAL CONDUIT AND CONDUCTORS AS <br /> REQUIRED. SEE DETAIL 1/E506-15 FOR INSTALLATION <br /> NOTES. <br /> PARTIAL PLAN VIEW ^I PROVIDE REMOTE MONITOR MODULES FOR EACH <br /> -0 <br /> SCALE: 1/8" = 1' " I V DEVICE. INSTALL IN EXISTING J-BOX. UTILIZE J-BOX <br /> / FOR CONNECTIONS BETWEEN FIELD DEVICES AND NEW <br /> BUILDING FIRE ALARM CONTROL PANEL. PROVIDE <br /> CONDUCTORS AS REQUIRED. <br /> CONNECT ALARM, TROUBLE AND SUPERVISORY POINTS <br /> FROM PANEL TO NEW BUILDING FIRE ALARM CONTROL <br /> PANEL. UTILIZE EXISTING INFRASTRUCTURE. PROVIDE <br /> ADDITIONAL CONDUIT AND CONDUCTORS AS REQUIRED. <br /> ®PROVIDE REMOTE ANNUNCIATOR AND CONNECTION TO <br /> NEW BUILDING FIRE ALARM CONTROL PANEL. UTILIZE <br /> EXISTING INFRASTRUCTURE. PROVIDE ADDITIONAL <br /> CONDUIT AND CONDUCTORS AS REQUIRED. <br /> PROVIDE CONDUCTORS AND CONNECTION(S) BETWEEN <br /> NEW MONITOR MODULE AND EXISTING SPRINKLER <br /> MONITORING DEVICE <br /> 6. COORDINATE WITH FIRE SPRINKLER CONTRACTOR FOR <br /> PIPING MODIFICATIONS AS REQUIRED. <br /> Q1 3 I 5 7 I 9 11 <br /> 1 TT(--, <br /> ?10 „ <br /> 1E260 _1E251 1E262 -1E263- 1E264 <br /> 1E265 1 IE'266 1E267 I IE268 I 1E269 <br /> IE271 1E272 1E273 ' 1E274 \� <br /> KEY PLAN <br /> SCALE: NONEN <br /> 8' 4 0 4' 8' 16 <br /> SCALE: 1/8"=1'-0" <br /> PO BOX 1138 <br /> AUBURN.WA 98071 <br /> SEATRONICS 253-939-6060 <br /> FIRE PROTECTION SERVICER,IBB RB. uw0 Bp, <br /> 111065 111065-1E270 <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE <br /> ACCEPTABILITY DRAWN RG A5.13.19 TE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> A EVEREF FIRE PANEL REPLACEMENT SEA 5.13.19 THIS DESIGN AND/OR FIRE ALARM SYSTEM PLAN-FIRST FLOOR 111065-0 5.13.19 <br /> SPECIFICATION IS APPROVED SHEET B 7 APPROVED BY DEPT. DATE � EVERETT FIRE PANEL REPLACEMENT 1 E2! O <br /> #APPROVED BUILDING 40-024 JOB NO. 111065 COMP NO. <br /> APPROVED ELECTRICAL MASTER COL. J-K/0.9-3 EVERETT, WA, DM No. 40-024-1E270 <br />
The URL can be used to link to this page
Your browser does not support the video tag.