Laserfiche WebLink
7 8 8.5 9 LEGEND <br /> SEE SHEET EOA FOR SYMBOLS AND ABBREVIATIONS. <br /> FOR CONTINUATION, SEE SHEET 1E268 <br /> `2"C DATA CONDUIT <br /> C, 4#12 3/4"C, 6#14 1"C, 4#12 I TO FOURTH FLOOR AT GRID <br /> ® J/8.6, SEE SHEET 4E273 <br /> A 4 �BUILDING FIRE ALARM <br /> 3/4"C, 8#12 EVTTfA— OOL A24L 3/4"C, 6#14 <br /> N -- <br /> 1/2"c, 6#14 I XS2V24 48UK10.7/3 3/4"C, (2)16/46 GENERAL NOTES <br /> w x—xj x x x--x=x x�— -- x_� A 1>40-24 FACP MONITORING POINTS: <br /> I 2 Q � S ELEV 21 FA <br /> LE ELEVATOR 21 1:01 SMK .r ELEV 21 TRBL <br /> Ix ACPQ — 77A ® fACP <br /> 3 1:13:11 ALM 2. SEE 40-25—TNE263 FOR SPRINKLER RISER VALVES <br /> cn <br /> w I% 1/2°C S L AND TAMPER SWITCHES <br /> co I E506-17 1:13:12 TRBL w <br /> 1:13:13 SUPV PCA 167 1:02 1® FACPN PULL OFFICE Imo' <br /> zI <br /> I 1"C, 4#12 y REFERENCE DRAWINGS <br /> z I <br /> CRAG G CONF. 0 3 E506-16 BUILDING FIRE ALARM RISER DIAGRAM <br /> 00 R00 , 1 8:12 SV24-19 WF Q <br /> H H 07:12 SV24-15 WIF <br /> C> EL TO 4 I ISO TAMPER I TAMPER z 4 E506-17 ELEVATOR FIRE ALARM RISER DIAGRAMS <br /> 1 1:07:11 SV24-15 x F ,: 7:14 SV24-17 WFQ �1 8:11 SV24-19 WF <br /> A E506-20 ELEVATOR 21 FIRE ALARM ENLARGED PLANS <br /> R O IS TAMPER P ESSURE o <br /> x H H 1/2"C PRESSURE 1:07:13 SV24-17 WFQ 2 <br /> P ESSURE o <br /> x _ _ _ D IFD SPD �- CONSTRUCTION NOTES <br /> — — — — PROVIDE MONITORING DEVICE ON EXISTING SPRINKLER <br /> IF _ _ _ _ _ RISER. CONNECT TO NEW BUILDING FIRE ALARM <br /> BLDG. 40-025 ELEVATOR CONTROL Q 1"C, 4#12 UP TO K CONTROL PANEL. UTILIZE EXISTING INFRASTRUCTURE. <br /> �1/2"C, 4#i6 2 1/2"C, 4#16Q SECOND FLOOR PROVIDE ADDITIONAL CONDUIT AND CONDUCTORS AS <br /> CABINET q 1/ "C, 4#16-7 REQUIRED. SEE DETAIL 1/E506-15 FOR INSTALLATION <br /> 3/4 C, 8#12 NOTES. <br /> PROVIDE REMOTE MONITOR MODULES FOR EACH DEVICE. <br /> INSTALL IN EXISTING J—BOX. UTILIZE J—BOX FOR <br /> CONNECTIONS BETWEEN FIELD DEVICES AND NEW <br /> BUILDING FIRE ALARM CONTROL PANEL. PROVIDE <br /> CONDUCTORS AS REQUIRED. <br /> PARTIAL PLAN VIEW �\ CONNECT ALARM, TROUBLE AND SUPERVISORY POINTS <br /> FROM PANEL TO NEW BUILDING FIRE ALARM CONTROL <br /> SCALE: 1/8" = 1'-0" I V PANEL. UTILIZE EXISTING INFRASTRUCTURE. PROVIDE <br /> ADDITIONAL CONDUIT AND CONDUCTORS AS REQUIRED. <br /> PROVIDE DIGITAL ADDRESSABLE FIRE ALARM CONTROL <br /> PANEL. REUSE 120VAC CIRCUIT. PROVIDE (2) SLC <br /> CIRCUITS, ONE FOR THE SOUTHEAST AND ONE FOR THE <br /> NORTHWEST OF BUILDING 40-24. SPLIT AT GRIDLINE <br /> 6.5. <br /> PROVIDE ADDRESSABLE MANUAL PULL STATION. <br /> CONNECT TO BUILDING FIRE ALARM CONTROL PANEL. <br /> PROVIDE CONDUIT AND CONDUCTORS AS REQUIRED. <br /> ©PROVIDE ADDRESSABLE SMOKE DETECTOR. CONNECT TO <br /> BUILDING FIRE ALARM CONTROL PANEL. PROVIDE <br /> CONDUIT AND CONDUCTORS AS REQUIRED. <br /> PROVIDE CONDUCTORS AND CONNECTION(S) BETWEEN <br /> NEW MONITOR MODULE AND EXISTING SPRINKLER <br /> MONITORING DEVICE <br /> S. COORDINATE WITH FIRE SPRINKLER CONTRACTOR FOR <br /> PIPING MODIFICATIONS AS REQUIRED. <br /> 1 3 5 7 9� Q Q Q Q ??'P' <br /> 1E260 i 1E261 i 1E262 i 1E263 1E264 <br /> 1E285 1E266 I 1E267 i 1E268 i 1E269 <br /> IE270 1E271 1E2721 1E274 \J <br /> KEY PLAN <br /> SCALE: NONE N <br /> 8' 4' 0 4' 8' 16 <br /> SCALE: 1/8"=1'-0" <br /> Po BOX 1138 <br /> AUBURN,-98071 <br /> SEATRONICS 253-939-6060 <br /> FIRE PROTECTION SE6VICE8 JOB N0. ONO N0. <br /> 111065 111065-1E273 <br /> SYM REVISION B4 APPROVED DATE SYM REVISION BY APPROVED DATE ACCEPTABILITY RG 5.13.19 SUBDiLE CURRENT REVISION SYMBOL GATE <br /> A EVERETT FIRE PANEL REPLACEMENT SEA 5.13.19 THIS DESIGN ArtD OR FIRE ALARM SYSTEM PLAN-FIRST FLOOR sHELT 111065-0 A 5.13.19 <br /> SPECIFICATION IS AP�ROVED <br /> BO rAV" APPROVED BY DEPT. DATE TRS CHECKED EVERETT FIRE PANEL REPLACEMENT 1 E273 <br /> Al BUILDING 40-024 JOB NO. 111065 COMP NO. <br /> APPROVED ELECTRICAL MASTER COL. J—K/7-9 EVERETT, WA. D-No' 40-024-1E273 <br />