SYSTEM DESIGNATIONS EQUIPMENT/DEVICES LIGHTING ABBREVIATIONS GENERAL NOTES:
<br /> HASH MARKS INDICATE THE QUANTITY OF CONDUCTORS $ SINGLE POLE TOGGLE SWITCH FIXTURE TYPE DESIGNATION. SEE FIXTURE SCHEDULE, A/C AIR CONDITIONING NIC NOT IN CONTRACT 1. PORTIONS OF THE BASE BUILDING ELECTRICAL,
<br /> (#12
<br /> WI E UN INSS/" CORD IT OTHERWISE NOTED). IF UNMARKED $3 THREE-WAY TOGGLE SWITCH 3 DWG. FEOID. QUANTITY AND RATING OF LAMPS AC ALTERNATING CURRENT NO NORMALLY OPEN ARE SHOWN WHERE THERE MAY BE
<br /> PHASE CONDUCTORS (A=TYPE, 2=QUANTITY, 34=LAMP RATING) A.R.F. ABOVE RAISED FLOOR NTS NOT TO SCALE INTERFERENCES, OTHER PORTIONS ARE NOT
<br /> $Lv SWITCH FOR LOW-VOLTAGE SWITCHING SYSTEM AWG AMERICAN WIRE GAUGE No. OR # NUMBER SHOWN FOR CLARITY. REFER TO THE BASE
<br /> NEUTRAL CONDUCTOR(IF REQUIRED) ® FLUORESCENT FIXTURE, 4 LAMP, TYPE AS NOTED AMP AMPERE OC ON CENTER BUILDING DRAWINGS TO COORDINATE WITH
<br /> GROUND CONDUCTOR(IF REQUIRED) $Lv(2) INDICATES THE NUMBER OF LOW VOLTAGE SWITCHES APPROX APPROXIMATE OD OUTSIDE DIAMETER OTHER WORK NOT IN THIS CONTRACT.
<br /> AS NOTED ON DRAWING. (EG. (2) INDICATES TWO ® FLUORESCENT FIXTURE, 3 LAMP, TYPE AS NOTED ARCH ARCHITECT OR ARCHITECTURAL PNL PANEL
<br /> 3V34-1J16/7,9,11 SWITCHES AT THIS LOCATION) AUTO AUTOMATIC % PERCENT
<br /> 3/4"C,3#8 PANEL HOME-RUN $D LIGHTING DIMMER SWITCH
<br /> _� PANEL/CIRCUIT FLOURESCENT FIXTURE, 2 LAMP, TYPE AS NOTED AUX AUXILIARY PERP PERPENDICULAR
<br /> CONDUIT/CONDUCTORS S3-D THREE-WAY LIGHTNIG DIMMER SWITCH BOT BOTTOM ? OR PH PHASE
<br /> BE BLDG BUILDING PVC POLYVINYL CHLORIDE
<br /> CONDUIT RUN EXPOSED r---1 PUSHBUTTON STATION FLOURESCENT FIXTURE ON EMERGENCY SYSTEM, CAB CABINET PWR POWER
<br /> TYPE AS NOTED CAT CATALOG PF POWER FACTOR
<br /> --- CONDUIT RUN CONCEALED IN WALLS, ABOVE CEILING, EZ MANUAL MOTOR STARTER Q CB CIRCUIT BREAKER PE PRESSURE ELECTRIC
<br /> IN FLOOR SLAB OR UNDERGROUND CLG CEILING PB PUSHBUTTON
<br /> -T- TELEPHONE, 3/4" MINIMUM, CONDUIT ONLY, UNLESS ® MAGNETIC MOTOR STARTER ® FLUORESCENT FIXTURE WITH BRANCH CIRCUIT CTR CENTER PR PAIR
<br /> CONNECTION POINT 1 LAMP, TYPE AS NOTED
<br /> SIZED OTHERWISE ® CHWR CHILLED WATER RETURN QTY QUANTITY
<br /> ZI COMBINATION STARTER, CIRCUIT BREAKER TYPE, CHWS CHILLED WATER SUPPLY RECP RECEPTACLE
<br /> -FO- FIBER OPTIC, 3/4" MINIMUM, WITH CABLE AS 30A UNLESS NOTED OTHERWISE ® FLUORESCENT FIXTURE WITH BRANCH CIRCUIT CKT CIRCUIT REF REFERENCE
<br /> INDICATED, UNLESS SIZED OTHERWISE. NO CONDULET ® ENCLOSED CIRCUIT BREAKER SIZE AS NOTED ® CONNECTION POINT 2 LAMP, TYPE AS NGTED COAX COAXIAL REQ'D REQUIRED
<br /> FITTINGS IN FIBER OPTIC RUNS ALLOWED. ON DRAWING ® COL COLUMN REV REVISION
<br /> -E- EMERGENCY CIRCUITDISCONNECT SWITCH, FUSED, 30=SWITCH RATING, ® FLUORESCENT FIXTURE WITH BRANCH CIRCUIT C CONDUIT RGS RIGID GALVANIZED STEEL
<br /> p.l
<br /> -FA- FIRE ALARM CIRCUIT 30/20 20=FUSE RATING ® CONNECTION POINT 3 LAMP, TYPE AS NOTED C.O. CONDUIT ONLY RM ROOM
<br /> CONT CONTINUE SECT SECTION
<br /> -PA- PAGING CONDUIT WITH WIRE AS NOTED DISCONNECT SWITCH, NON-FUSED, 30A CU COPPER SHT SHEET
<br /> ly UNLESS NOTED OTHERWISE ® FLUORESCENT FIXTURE WITH BRANCH CIRCUIT CT CURRENT TRANSFORMER SIM SIMILAR
<br /> -G- COPPER GROUND WIRE, SIZE AS NOTED CONNECTION POINT 4 LAMP, TYPE AS NOTED DC DIRECT CURRENT SPOT SINGLE POLE DOUBLE THROW
<br /> -Lv- LOW VOLTAGE CONDUIT WIRE ® WALL MOUNTED OUTDOOR FLOODLIGHTING FIXTURE,MOTOR CONTROLLER DED DEDICATED CIRCUIT SPST SINGLE POLE SINGLE THROW
<br /> / DEG DEGREE SPEC SPECIFICATION
<br /> CONDUIT TURNED UP ® CAPACITOR TYPE AS NOTED DET DETAIL ST SHUNT TRIP
<br /> CONDUIT TURNED DOWN �( HIGH INTENSITY DISCHARGE FIXTURE, TYPE AS NOTED DIAM DIAMETER SUSP SUSPEND
<br /> -� ® TRANSFORMER, SIZE AND TYPE AS NOTED DISC DISCONNECT SW SWITCH
<br /> M HIGH INTENSITY DISCHARGE FIXTURE, TYPE AS NOTED DPDT DOUBLE POLE DOUBLE THROW SYS SYSTEM
<br /> V'L
<br /> rT FLEXIBLE CONDUIT, 1/2" UNLESS NOTED OTHERWISE (� MOTOR, 120V, 10, SIZE AS NOTED MS WHEN MORE THAN ONE LAMP TYPE IS USED IN AN DPST DOUBLE POLE SINGLE THROW TEL TELEPHONE
<br /> AREA (M=METAL HALIDE LAMP, S=HIGH PRESSURE DN DOWN T'STAT THERMOSTAT
<br /> ..F.. PRE-WIRED FLEXIBLE CONDUIT PROVIDED WITH LIGHT () MOTOR, 208V, 30, SIZE AS NOTED SODIUM LAMP) DWG DRAWING XFMR TRANSFORMER
<br /> FIXTURE TYPES R, R-2, S AND S-2 AS LST (LABOR- INCANDESCENT OR COMPACT FLUORESCENT FIXTURE, EA EACH TYP TYPICAL
<br /> SAVING TANDEM). MOTOR, 460V, 30, SIZE AS NOTED TYPE AS NOTED EL ELEVATION UH UNIT HEATER
<br /> CABLE TRAY, SIZE AS NOTED ON THE DRAWINGS JUNCTION BOX, FIELD SIZED OR AS NOTED INCANDESCENT OR COMPACT FLUORESCENT FIXTURE ELECT ELECTRIC UG UNDERGROUND
<br /> ON EMERGENCY SYSTEM, TYPE AS NOTED EMT ELECTRCAL METALLIC TUBING U.O.N. UNLESS OTHERWISE NOTED
<br /> cz GROUNDING PIGTAIL EMER EMERGENCY
<br /> �) EXIT LIGHTING SIGN, WALL MOUNTED. ENGR ENGINEER VERT
<br /> VARIABLE AIR VOLUME
<br /> PB
<br /> CONDUIT TO BE REMOVED PULLBOX, FIELD SIZED OR AS NOTED VERER T VERTICAL
<br /> DIRECTION OF EGRESS AS NOTED EQUIP EQUIPMENT WP WEATHERPROOF
<br /> ® EQUIPMENT TO BE REMOVED (EG. PANELBOARD) JB 1 JUNCTION BOX, SPECIAL FIELD SIZED OR AS NOTED ® EXIT LIGHTING SIGN, SUSPENDED OR CEILING ETC ETCETERA WH WATER HEATER
<br /> ?ENERATOR ALTERNATING CURRENT
<br /> MOUNTED. DIRECTION OF EGRESS AS NOTED EWC ELECTRIC WATER COOLER WW WATT
<br /> / WITH
<br /> EXIST EXISTING VOLTAGE, kW, FREQUENCY AS NOTED) O FIXTURE OUTLET (SHOWN WITH FIXTURES) C EXTR EXTERIOR W/0 WITH OUT
<br /> O GROUND ROD, SIZE AS SPECIFIED OR NOTED
<br /> DISTRIBUTION PP LIGHTING TRANSFORMER/RELAY POWER RACK
<br /> / (SHOWN
<br /> N TELEPHONE OUTLET, WALL MOUNTED 12" ARF OR AS NOTED FA FIRE ALARM CON OL PAN L NOTE: SEE SHEET E506 FOR FIRE ALARM ABBREVIATIONS
<br /> X30-3P 208 r. LENGTHSONTHE7DWG.)SW30-3P OINDICATES I4 DATA OUTLET, WALL MOUNTED 12" ARF OR AS NOTED $4 LUTRON ECOSYSUTTON TEM
<br /> CC-BRLL RATION, FACP FIRE ALARM CONTROL PANEL
<br /> FATC FIRE ALARM TERMINAL CAB NET
<br /> 30 AA�M�P, 3 POLE, PLUG-IN UNIT ® TELEPHONE OUTLET MOUNTED IN RAISED FLOOR RS ECOSYSTEM DIGITAL BUS SUPPLY,
<br /> LUTRON MODEL # CS-iL-WM FIXT FIXTURE
<br /> ® PANELBOARD, 48OV, 3?, 3W, PANELBOARD p DATA OUTLET MOUNTED IN RAISED FLOOR FLEX LE C
<br /> O PUSHBUTTON STATION, TYPE AS NOTED FLR FLOOR
<br /> ® PANELBOARD, 480Y/277V, 3?, 4W, PANELBOARD, RECEPTACLES FT FOOT
<br /> SURFACE MOUNTED, FLUSH MOUNTED FURN FURNISH
<br /> O THERMOSTAT 30SINGLE,
<br /> XI GRO WTH ND BTHRU3EXTRA POLE AWITH
<br /> D SHELL. GEN GENERATOR
<br /> PANELBOARD, 208Y/120V, 3?, 4W, PANELBOARD
<br /> SURFACE MOUNTED, FLUSH MOUNTED C❑ CONTACTOR, TYPE AS NOTED GRN GREEN PANEL NOMENCLATURE
<br /> DUPLEX, 20A, 120V, 10, 2P, 3W, PARALLEL BLADE GND GROUND XE 3 V03-1 U D12-1-D
<br /> Mcc MOTOR CONTROL CENTER ® CONTROL PANEL GROUNDED HTR HEATER
<br /> HGT HEIGHT T L SUFFIX "-D" INDICATES DISTRIBUTION PANEL
<br /> O 400Hz PANEL C fi EXPLOSION PROOF SEAL FITTING c DUPLEX, 20A, 120V, 10, 2P, 3W, PARALLEL BLADE HID HIGH INTENSITY.DISCHARGE �-
<br /> ® RELAY WITH ISOLATED GROUND, ORANGE HZ HERTZ SUFFIX "-1, -2, -3, ETC." IS USED TO
<br /> a SPECIAL PANEL AS NOTED FOURPLEX-2 DUPLEX, 20A, 10, 2P, 3W HPS HIGH PRESSURE SODIUM INDICATE MULTIPLE PANELS AT SAME LOCATION
<br /> F INDICTES WALL MOUNTING # PARALLEL BLADE GROUNDED. HV HIGH VOLTAGE WHICH ARE SAME VOLTAGE, FED FROM SAME
<br /> VAULT AND LOCATED ON SAME FLOOR
<br /> SYSTEM
<br /> © SOLENOID VALVE HORIZ HORIZONTAL
<br /> FIRE ALARM JYJTEM WP WEATHERPROOF DUPLEX RECEPTACLE, 15A, 120V, 10, HP HORSEPOWER NOTE: IF SUFFIX "-A, -B, -C, ETC." IS BEING
<br /> ® TELEPHONE/DATA/POWER POLE 9 2P, 3W PARALLEL BLADE, GROUNDED IG ISOLATED GROUND
<br /> USED INSTEAD OF "-1, -2, -3, ETC.", THEN
<br /> FF ELEVATOR ALARM BELLIN INCH
<br /> cFl GROUND FAULT INTERRUPTER TYPE DUPLEX RECEPTACLE CONTINUE USING SUFFIX LETTERS FOR CLARITY
<br /> ® COMBINATION FLUSH FLOOR BOX WITH Q 20A, 120V, 10, 2P, 3W PARALLEL BLADE, GROUNDED INFO INFORMATION
<br /> F� FIRE ALARM HORN, WALL OR CEILING FOUR NEMA 5-15R OUTLETS JB JUNCTION BOX PANEL LOCATION AT NEAREST COLUMN
<br /> a DUPLEX RECEPTACLE, 20A, 120V, 10, 2P, 3W, KW KILOWATT LOCATION OF PANEL WHEN NOT ON FIRST FLOOR:
<br /> FIRE ALARM HORN/STROBE, WALL OR CEILING ® COMBINATION FLUSH FLOOR POKE-THRU WITH PARALLEL BLADE GROUNDED, MOUNTED IN RAISED KWH KILOWATT HOUR M = MEZZANINE U = 2ND FLOOR
<br /> FLOOR P = PENTHOUSE UT = UTILIDOR
<br /> FOUR NEMA 5-15R OUTLETS KV KILOVOLT
<br /> Ox:xx SMOKE DETECTOR, SUBSCRIPT X:XX = DEVICE ADDRESS Q Ic DUPLEX RECEPTACLE, 20A, 120V, 10, 2P, 3W, PARALLEL LGTH LENGTH R = P1 PARKING FLOOR V = 3RD FLOOR
<br /> BLADE WITH ISOLATED GROUND, ORANGE. MOUNTED IN LT LIGHT S = P2 PARKING FLOOR W = 4TH FLOOR
<br /> AUXILIARY SYSTEMS RAISED FLOOR
<br /> QF MANUAL STATION, SUBSCRIPT X:XX = DEVICE ADDRESS LG LONG T = TRUSS LEVEL X = 5TH FLOOR
<br /> x:xx "WP" = WEATHERPROOF, "EP" = EXPLOSIONPROOF Q P.A. �SISTEM ATTATOR, WALL MOUNTED ® FOURPLEX-2 DUPLEX RECEPTACLE, 20A, 120V, 10, 2P, 3W, MAG MAGNETIC TN = TUNNEL
<br /> to W TT ;J PARALLEL BLADE GROUNDED, MOUNTED IN RAISED FLOOR MAINT MAINTENANCE
<br /> wF xx WATERFLOW SWITCH, SUBSCRIPT X:XX = DEVICE ADDRESS, (1 O= 0 A RAI MFG MANUFACTURER SOURCE OF POWER: VAULT NO.
<br /> x:xx "P" = PRESSURE TYPE, "PD" = PRESSURE TYPE W/DELAY �Kl P.A. SYSTEM SINGLE HORN a FOURPLEX-2 DUPLEX RECEPTACLE, 20A, 120V, 10, 2P, 3W, MAX MAXIMUM FLIGHTLINE EXAMPLE: VS38 FOR SUBSTATION S38
<br /> PARALLEL BLADE WITH ISOLATED GROUND, ORANGE. MOUNTED
<br /> ®x,xx HI/LO AIR PRESSURE SWITCH D°4 IN RAISED FLOOR MECH MECHANICAL
<br /> SUBSCRIPT X:XX = DEVICE ADDRESS
<br /> ori t P.A. SYSTEM TWO(2) HORN CLUSTER MEZZ MEZZANINE VOLTAGE AND ASSOCIATED PANEL SYMBOL:
<br /> L�-) TWO
<br /> 0(2) PARALLELRBLADERGROUNADED, MOUNTEDOIN, RAISED FLOOR MIN MINIMUM
<br /> VS P.A SYSTEM THREE(3) HORN CLUSTER MISC MISCELLANEOUS ® 4 = 480V, 3PH, 3W
<br /> ❑x,� TAMPER SWITCH (VALVE SWfTCH) �/,� MTD MOUNTED L� 3 = 480Y/277V, 3PH, 4W
<br /> SUBSCRIPT TER = DEVICE ADDRESS �Q P.A. SYSTEM FOUR(4) HORN CLUSTER SIG) TWO PARALLELRPLEX BLADE. 1E DUPLEX SHALLIBEVISOLATED GROUND, MTG MOUNTING ® 2 = 208Y/12OV, 3PH, 4W OR 120/24OV, 1PH, 3W
<br /> FF-AT-Cl FIRE ALARM TERMINAL CABINET ORANGE. THE OTHER THREE DUPLEX SHALL BE NORMAL, NEC NATIONAL ELECTRIC CODE © 5 = 400 HZ, 575Y/331V, 3PH, 4W
<br /> ` ` / FACP FIRE ALARM CONTROL PANEL Q SPEAKER, RECESSED MOUNTED IN CEILING IVORY. U.O.N. MOUNTED IN RAISED FLOOR NC NORMALLY CLOSED L� 2 = 400 HZ, 200Y/1 15V, 3PH, 4W
<br /> J■_ � �
<br /> ANN ANNUNCIATOR (FIRE ALARM) C� 1 28 VDC
<br /> TELEPHONE CABINET PREFIX: (BLANK} = NORMAL POWER PANEL
<br /> ® COMBINATION FLUSH FLOOR BOX WITH
<br /> ®
<br /> "I" = ISOLATED GND PANEL
<br /> MISCELLANEOUS PANEL/EQUIPMENT, TYPE AS NOTED TELEPHONE/DATA/AV SYSTEM ROUGH-IN "Z" = 400 HZ PANEL
<br /> "XE" = EMERGENCY PANEL
<br /> "XL" = LEGALLY REQUIRED STANDBY PANEL
<br /> p5w "XS" = OPTIONAL STANDBY PANEL
<br /> OW ISSUE FOR CONSTRUCTION �
<br /> APRIL 24, 2019 4
<br /> SYM REVISION BY APPROVED DATE SYM RENSION BY APPROVED DATEWN SUBTITLE CURRENT REVISION SYMBOL OATS
<br /> ACCEPTABILITY AAS 6-26-95 „
<br /> RECORD DRAWING ISSUED TO OWNER AAS JRB 06.30.95 D EVERETT FIRE PANEL REPLACEMENT W2640474 SAZAN/ZO 04.24.19 THIS DESIGN AND/OR ELECTRICAL LEGEND AND ABBREVIATIONS E 08.16.19 'o
<br /> SPECIFICATION IS APPROVED JRB 6-26-95 sMEEr
<br /> A 767 LEADERSHIP&SUPPORT CELL 10150643 AEI OE 07.08.10 E EVEREff FIRE PANEL REPLACEMENT AGOW/HG 08.16.19 ® ® APPROVED BY DEPT. DATE TITLE EVERETT FIRE PANEL REPLACEMENT EOA n
<br /> - RECORD DRAWING 10150643 AEI OE 03.01.11 BOE/A/O CHECKED
<br /> / BETE UNAMEK BUILDING 40-033 JOB NO. COMP N0.
<br /> B RFlD SCANNER RECEPTACLES-RECORD DRAWING 1211218 SAZAN PT 01.13.15 arty $
<br /> C EVERETL SRE HVAC REPLACEMENT WAC-6-RECORD 19081703 SAZAN/ZO 02.22.18 - n, ELECTRICAL MASTER EVERETT, WA. owc No. 40-033-EOA