My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-33 2024-02-09
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-33
>
3003 W CASINO RD BLDG 40-33 2024-02-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2024 9:18:58 AM
Creation date
12/20/2023 9:26:58 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-33
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 1 1 1 11 '.5 12 12 5 13 I LEGEND <br /> SEE SHEET EOA FOR SYMBOLS AND ABBREVIATIONS. <br /> w <br /> x <br /> N <br /> w <br /> w <br /> N <br /> Z <br /> H <br /> Ir- <br /> Ll-022 ALM <br /> 1 2 1 1 2'"""'• 1 CERBERUS CP-35 FACP 15 L1:023 TRBL <br /> L_j Li LiS S s s S � <br /> ❑ Lj Li 1/2"C, 6#14 <br /> I .......... .... ... ...... .... . TO BUILDING FACP- I <br /> F <br /> 8#141 <br /> 8#1 <br /> 1/2"C,8#14 <br /> SEE NOT 9 w, 28#14 8#14 40 14 A <br /> 8#1 2 8#1 411 NOTE 9 <br /> s S 2#14 4#14 <br /> 2#1 tl-#l4J A <br /> ABORT STATION WITH <br /> 4##1 ISIGNAL LIGHT, NOTE <br /> LEPH TLET 10 TYPICAL <br /> IMANUAL STATION FOR <br /> NOT 3 3 2F- I 8 1 POWER SHUT-OFF <br /> :::: ::: <br /> TELEPHONEAHIS 8#14 S g 14 W/PROTECTIVE GUARD <br /> T ❑ ❑ <br /> 4# /m <br /> EE NO 8 1 14#14 <br /> u Li ❑ ❑ ❑ 4#14 <br /> :A2' iE • d: ::: ::. .1: ii:::: :::::: <br /> S S S S s NOTE 9 <br /> r-i_ I A <br /> GENERAL NOTES CONT. _ <br /> 15 40-33 FACP MONITORING POINTS: <br /> CERBERUS SERVER RM FA <br /> CERBERUS SERVER RM TRBL <br /> PARTIAL PLAN VIEW N <br /> SCALE: 1/8"=1'-0" <br /> GENERAL NOTES REFERENCE DRAWINGS <br /> 1. SEE SMOKE DETECTOR MOUNTING DETAILS ON DWG. e. SUPERVISED BYPASS AT FIRE ALARM PANEL SHALL: 13. THE ABORT STATION SHALL BE LABELED WITH A 6- <br /> E500 FOR CEILING. 1.) SEND TROUBLE SIGNAL TO ADT WHEN IN X 3" PHENOLIC SIGN WITH YELLOW BACKGROUND <br /> 2. FIRE ALARM STROBE LIGHT, HORN, AND BELL SHALL BYPASS MODE AND BLACK 1/2" LETTERS, TO READ: <br /> BE MOUNTED AT BE LIG ABOVE RAISED FLOOR. 2.) PREVENT A SHUTDOWN OF THE HVAC AND <br /> POWER WHEN ACTIVATED POWER & HVAC SAVE SWITCH <br /> 3. FIRE ALARM SYSTEM SHALL BE A CROSS ZONED 4. NUMBER AT SMOKE DETECTOR SYMBOL INDICATES PRESS AND HOLD TO PREVENT <br /> SMOKE DETECTION SYSTEM OPERATING FIRE ALARM ZONE. SHUTDOWN A r: <br /> AS FOLLOWS: <br /> D <br /> . 1st DETECTOR TO ACTUATE SHALL: 5. SMOKE DETECTORS SHALL BE IONIZATION TYPE 14. THE AMBER LIGHT AT THE ABORT STATION SHALL BE CONSTRUCTION NOTE S <br /> 1. TRANSMIT ALARM SIGNAL TO ADT CONNECT ALARM, TROUBLE AND SUPERVISORY POINTS <br /> 2. SOUND ALARM BELL IN ROOM 6. SEAL ALL PENETRATIONS TO THE ROOM, WITH FIRE LABELED WITH A 1-1/2" X 4" PHENOLIC SIGN WITH <br /> 3. TURN ON STROBE LIGHT SIGNAL RATED SEALANT. YELLOW BACKGROUND AND BLACK 3/16" LETERS FROM PANEL TO BUILDING 40-33 MAIN FIRE ALARM <br /> 4. LIGHT APPROPRIATE ZONE LAMP ON 7, ALL WIRING SHALL BE IN 1/2"C UNLESS NOTED TO READ: CONTROL PANEL, FIRST FLOOR COL. H.5/17. UTILIZE <br /> THE CONTROL PANEL OTHERWISE. EXISTING INFRASTRUCTURE. PROVIDE ADDITIONAL <br /> POWER SHUTDOWN SAVED CONDUIT AND CONDUCTORS AS REQUIRED. <br /> b. 2nd DETECTOR TO ACTUATE SHALL (CROSS ZONE): 8• VERIFY ALL QUANTITIES OF WIRE WITH SUPPLIER OF HVAC RESTARTED IF PREVIOUSLY <br /> 1. CONTINUE ALARM SIGNAL TO ADT. FIRE ALARM SYSTEM. SHUTDOWN <br /> 2. SOUND HORN <br /> 3. CONTINUE STROBE LIGHT SIGNAL 9. MOUNT THIS LIGHT AT 6'-9". PROVIDE PLACARD AT <br /> 4. SHUT OFF BELL LIGHT, LOGO: "COMPUTER ROOM FIRE ALARM NOTIFY <br /> 5. SHUT OFF HVAC FIRE DEPARTMENT 342-2222". SIGN SHALL BE RED <br /> 6. SHUT OFF POWER (AFTER 60 SECONDS DELAY) PLASTIC BACKGROUND WITH 1" HIGH WHITE LETERS. <br /> 7. LIGHT APPROPRIATE ZONE LAMP ON <br /> THE CONTROL PANEL 10.ABORT STATION/SIGNAL LIGHT SHALL BE SAFETECH <br /> n 13 1s 16 n <br /> c. ABORT STATION SWITCH SHALL: # 50-2005 1z <br /> 1.) SEND TROUBLE SIGNAL TO ADT 11. THE ALARM BELL SHALL BE LABELED WITH A 6" X BLDG 40-22 BL G 41-3 <br /> 2.) LIGHT LAMP AT ABORT SWITCH 3" PHENOLIC SIGN WITH RED BACKGROUND AND --- I_�_ __ __� F <br /> 3. RESET AND HOLD THE HVAC AND POWER WHITE 1/2" LETTERS, TO READ: _I I <br /> SHUTDOWN DELAY SEQUENCE TO PREVENT NOTE: ii <br /> G <br /> HVAC AND POWER SHUTDOWN CONTACTS 1ST ALARM I I I I I <br /> FROM OPERATING / THE INFORMATION SHOWN ON THIS SHEET HAS BEEN BLDG 40-23 I BLbG 0-3 <br /> FIRE DEFECTION <br /> 4.) START THE HVAC IF IT HAD BEEN SHUT i <br /> COMPILED FROM SEVERAL SOURCES INCLUDING, BUT NOT <br /> LIMITED TO: I I <br /> WARNING 4E 64 4E 65 4E 66 H <br /> OFF BY A CROSS-ZONE DEFECTION CONDITION I <br /> 5.) SOUND LOCAL TROUBLE ALARM DEVICE IN THE 12. THE ALARM HORN SHALL BE LABELED WITH A 6" X SHEET 40-33-4E455 --- -- " <br /> FIRE DETECTION PANEL, AND TURN ON THE 3" PHENOLIC SIGN WITH RED BACKGROUND AND <br /> TROUBLE LIGHT ON THE PANEL ♦ SHEET 40-33.4-F4E550 BLDG 40-24 BLDG 40-34 <br /> d. RELEASING THE ABORT STATION SWITCH SHALL: WHITE 1/2" LETTERS, TO READ: KEY PLAN <br /> 1.) TURN OFF LIGHT AT ABORT STATION WITH THE EXCEPTION OF MAENCES,E TEXT AND KEY N <br /> 2. RESTART THE TIME DELAY SEQUENCE IFA 2ND ALARM PLANS, ALL DRAWING REFERENCES, SECTION MARKS, SCALE: NONE <br /> CROSS-ZONE DEFECTION CONDTFION OCCURS, FIRE DETECTION ISSUE FOR CONSTRUCTION DETAIL MARKS, AS SHOWN ON THIS SHEET, SHALL BE <br /> AND SHUT OFF THE HVAC HVAC SHUTDOWN & COUNTDOWN REFERRED TO THE SOURCES AS INDICATED. 8' 4' 0 4' 8' 16' <br /> TO POWER SHUTDOWN APRIL 24 2019 Aowi <br /> SCALE: 1/8"=1'-0" <br /> SYM REVISION BY APPROVED DAZE SYM REVISIONBY APPROVED DATE ACCEPTABILITY ZD DRAWN 04.24.19 SUBTITLE CDRRENT REVISION SYMBOL TE r <br /> A EVERETT FIRE PANEL REPLACEMENT W2640474 SAZAN/TK 04.24.19 THIS DESIGN AND/OR FIRE DETECTION PLAN-FOURTH FLOOR B 08.16.19 <br /> B EVERETf FIRE PANEL REPLACEMENT AGOW/HG 06.16.19 SPECIFICATION IS APPROVED ZO 04.24.19 BOE//V6® m SPR <br /> DEPT. DATE CK 04.24.19 TITLE EVERE17 FIRE PANEL REPLACEMENT SHEET 4E264 N <br /> CHECKED <br /> �: ""12. A"`"nAPPROVEDBUILDING 40-033 JOB NO. - COMP NO. <br /> DWG NO. <br /> ELECTRICAL MASTER COL H-1/1 l'-1 3 EVER L?T, WA. 40-33-4E264 <br />
The URL can be used to link to this page
Your browser does not support the video tag.