Laserfiche WebLink
Lighting Summary, cont. LTC -SUM <br /> 2015 Seattle Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised Aug 2019 <br /> Project Title: Gyro Stop 7430 Evergreen Way iDate 8/4/2021 <br /> • <br /> Change of Space Use Existing interior lighting systems in areas under-going a change in space use are upgraded to <br /> comply with LPAs for the new space types per Tables C405.4.2(1)or C406.4.2(2). <br /> Identify Interior spaces requiring LPD upgrede to the current Code In Proposed Lighting Wattage table In <br /> LTG-INT-BLD or LTG-INT-SPACE form. <br /> Interior and Exterior Lighting Power Interior lighting Parking garage Exterior lighting <br /> Lighting Alterations Spaces with more lighting than threshold <br /> added,altered or replaced 0 ❑ ❑ <br /> (20%int.,50%garage,50%ext.) <br /> Select all Lighting Power and Lighting Spaces with less lighting than threshold ❑ ❑ __ <br /> Control elements that apply to the scope added,altered,or replaced <br /> of the retrofit project.If project includes (20%int.,50%garage,50%ext.) <br /> multiple spaces(roams separated by Lamp and/or ballast replacement only <br /> selling height partitions),each space existing total wattage not increased ❑ 0 ❑ <br /> where less than 20%of the existing <br /> fixtures are added,altered or replaced can More lighting than threshold replaced-Total lighting power of new+existing-to-remain fixtures shall <br /> be combined on a single LTG-INT-SPACE comply with total LPA per Sections C405.4.2 and C405.5.2. Include new+existing-to-remain fixtures in <br /> form. Spaces where 20%or more of the proposed Lighting Wattage table/n LTG-INT-BLD,LTG-INT-SPACE or LTG-EXT fort. <br /> Postures am added,altered or replaced Less lighting than threshold replaced-Total lighting power of new+existing-to-remain fixtures shall <br /> and additions may be combined onto one not exceed the total lighting power prior to alteration. Include new+exIstfng-to-remain fixtures in the <br /> fighting power compliance tiorm.Parking Proposed Lighting Wattage table in LTG-INT-BLD,LTG-INT--SPACE or LTG-EXT form. <br /> garages and exterior lighting have 50%thresholds. The threshold for Interior lighting Is 20%of the luminaires within an enclosed space,for parking garages <br /> the threshold is 50%of the luminaires within the garage,and for exterior spaces the threshold Is 50%of <br /> Refer to Section C503.6 for additional the total Installed lighting power for the exterior luminaires. <br /> requirements. lighting Controls Interior lighting <br /> g rig Parking garage Exterior lighting <br /> All aheration lighting controls shall be New wiring installed to serve added ❑ ❑ ❑ <br /> commissioned per C408.3. fixtures and/or fixtures relocated to new <br /> circuits) <br /> New or moved lighting panel ❑ ❑ [] <br /> Interior space is reconfigured © - <br /> luminaires unchanged or relocated only <br /> New wiring or circuit-For Interior fighting,provide required manual controls per C405.2.3,occupancy <br /> sensor controls per C405.2.1,daylight responsive controls per C405.2.4 and application specific lighting <br /> (� No changes are being made to controls per C405.2.5.For exterior fighting,provide required controls per C405.2.7. <br /> the interior or exterior lighting New or moved panel-Provide all applicable lighting controls as noted for New Wiring and automatic <br /> systems and existing space time switch controls per C405.2.2. <br /> uses and configuration are not Reconfigured Interior space-Provide all required lighting controls that apply to a new interior space. <br /> changed. Application specific lighting control provisions per C405.2.5 do not apply to reconfigured spaces, <br />