My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7430 EVERGREEN WAY GYRO STOP 2024-02-09
>
Address Records
>
EVERGREEN WAY
>
7430
>
GYRO STOP
>
7430 EVERGREEN WAY GYRO STOP 2024-02-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2024 3:29:00 PM
Creation date
12/21/2023 8:59:40 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
7430
Tenant Name
GYRO STOP
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
58
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• • System Design <br /> 3-6.1.1, DUCTS <br /> The ADP nozzle, P/N 87-12001 1-001 is used for protection of the exhaust ductwork, <br /> The duct cross section can be any shape, not including obstructions (i.e., round, square, or <br /> rectangular) and the duct itself can be of unlimited Iength. In accordance with NFPA 96, the exhaust <br /> fan should be left running at the time of system discharge. This will help to remove smoke and other <br /> airborne materials and gases from the hazard area in the event of a fire. Check with the Authority <br /> Having Jurisdiction for local requirements. A damper, if present, should be left open at system <br /> discharge. However, if the damper is closed, the system designer must insure that additional nozzles <br /> are required. <br /> 3-6.1.1.1 Protection of Ducts 0 to 50 inches in Perimeter <br /> One ADP nozzle, P/N 87-1 200 1 1-001, is required for protection of a duct with a perimeter up to 50- <br /> inches (refer to Figure 3-29). Length of duct is unlimited. <br /> The nozzle is located at the geometric center of the cross-sectional area that it is protecting, and is <br /> located in the duct within six inches of the entrance. <br /> Note: All Range Guard systems are listed by UL and ULC for use with the exhaust fan either on or <br /> off when the system is discharged. <br /> DUCT <br /> i I <br /> E z <br /> HOOD <br /> DUCT PERIMETER UP TO AND INCLUDING 50 in.(1270 mm) <br /> 11.78 in.(300 mm) 15.91 in. <br /> MAX. DIAGONAL <br /> (404 nun) <br /> .�-MAX...0„I i.F..-.—•. "B" <br /> 12.5 in. ? _ 1 11.78 in.(300 mrn) <br /> _._(318 mm) MAX.DIAGONAL <br /> ...... -.._._ . <br /> MAX. f I <br /> SQUARE DUCT * RECTANGULAR DUCT <br /> 2"A"+2 "B"=65 in. (1651 mm) <br /> ROUND DUCT <br /> • <br /> OF VERTICAL DUCT <br /> ADP NOZZLE <br /> �- AIM POINT <br /> VERTICAL/HORIZONTAL DUCT = <br /> S <br /> 0-6 in.(0-152 mm) <br /> i <br /> ADP NOZZLE � r� <br /> DUCTENTRANCE 4.OF HORIZONTAL DUCT <br /> 2 to 4 in.(51 to 102 mm) <br /> [ NOZZLE TIP to DUCT HIP <br /> Figure '3-29. Duct Protection Using Single ADP Nozzle, P/N 8'7-12001 1-001 <br /> PiN 60-9I 27100.000 3-35 J 1\ April 2009 <br />
The URL can be used to link to this page
Your browser does not support the video tag.