Laserfiche WebLink
Mr. Drew Martin <br /> 2713 Maple Street, LLC <br /> Plan Check Number: B2101-051, Second Building Review <br /> March 7th, 2022 <br /> Second Floor. The construction of the new interior and exterior walls, foundations, and stair <br /> landings is not included. Structural drawing should be submitted that include framing plans, <br /> sections, details, construction schedules, fastening schedules, materials requirements, general <br /> notes, special inspection requirements, etc. The drawings should substantiate compliance with <br /> the prescriptive requirements of the IRC. Alternatively, an engineered design may be <br /> performed for portions of the structural design per Section R301.1.3. See Sections R106.1.1 <br /> and R301.1. <br /> The design has been engineered. Structural calculations were provided with the submittal and <br /> revised calculations with this resubmittal. <br /> 2. A general fastener schedule should be provided per IRC Table R602.3(1). Providing a reference <br /> to this table in the drawings does not satisfy this requirement. In addition, the make and model <br /> of proprietary hardware should be specified where used for connections. <br /> Exterior walls have been analyzed/designed in accordance with the AWC NDS. Shear wall and hold <br /> down schedules were provided with the as-built information on Dwg No. A1.2 and are still <br /> adequate, as shown in the structural calculations. Actually, by filling in the large bay doors, the <br /> structural performance will only be improved. The original fastener schedule was also provided on <br /> Dwg No. A1.2. <br /> 3. Details for the construction of the new walls should be included. The details should specify <br /> connections for the top and bottom framing plates to the existing structure. See IRC Sections <br /> R106.1.1 and R301.1. <br /> The new walls are primarily interior partition walls. Standard interior and exterior wall details are <br /> shown on architectural and structural details sheets. <br /> 4. The proposed design includes modifications to the existing wall bracing. The drawings should <br /> be revised to show the modified wall construction. The braced wall lengths should be specified. <br /> See IRC Section R106.1.3. <br /> The existing walls have been analyzed. Shear wall schedule has been added to the proposed floor <br /> plans to match existing shear wall schedule already shown on Dwg No. A1.2. <br /> 5. The new and modified bearing and braced walls require new foundations. Details for the <br /> foundations should be included in the construction drawings. Anchorage is required per <br /> Sections R403.1.6 and R602.11.1. See Sections R403 and R404. <br /> There are no new bearing walls and no proposed changes to the shear walls. All loads are <br /> transferred at the exterior walls. Existing foundations are adequate per the structural calculations <br /> provided. <br /> 6. Framing details for openings in the walls including headers, and king and jamb studs, should be <br /> included in the construction drawings. See Section R602.7 and R602.7.5. <br /> Standard wall & header details have been added <br /> Page 6 of 8 i <br />