My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2713 MAPLE ST A & B 2024-01-08
>
Address Records
>
MAPLE ST
>
2713
>
2713 MAPLE ST A & B 2024-01-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/8/2024 4:11:24 PM
Creation date
12/21/2023 10:04:39 AM
Metadata
Fields
Template:
Address Document
Street Name
MAPLE ST
Street Number
2713
Unit
A & B
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
55
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr. Drew Martin <br /> 2713 Maple Street, LLC <br /> Plan Check Number: B2101-051, Third Building Review <br /> May 9th, 2022 <br /> Reference Only— Not For Construction". The structural design should not reference the record <br /> drawings for the current work or otherwise use them in lieu of specifying the required <br /> information to perform the current project. Information provided in these drawings was not <br /> developed using the current codes. In addition, the scaling and quality of the drawings renders <br /> them partially illegible. See Section R106.1.1. <br /> A note has been added to both sheets, "For Reference Only—Not for Construction. <br /> 7 Changes to the drawings have been indicated in red text. All drawing work should be show <br /> using black text. Changes may be clouded for clarity. <br /> Revision call outs have been updated. <br /> Archi ectural <br /> . , Detail 6/A6 showing a cable-guard has been added. The following comments should be <br /> __.- addressed: <br /> a. The proposed locations for the guard are not clear and should be specified in the plans. <br /> See Section R106.1.1. <br /> b. The details specify a larger sphere than allowed per Section R312.1.3. In addition, the <br /> cables are prone to splaying at the midpoints. Cables should specify a maximum spacing of <br /> 3 inches and also specify that they are installed with sufficient tension to prevent passage of <br /> a 4-inch sphere at their midpoints. <br /> c. The detail should specify that the guards and their base connections be designed for a <br /> minimum 200-pound load in any direction. See Table R301.5. <br /> d. Sheet A0.0 should include a section titled "Deferred Submittals"and list the guards. The <br /> section should include a note requiring the guard design to be submitted to the engineer-of- <br /> record for review and approval prior to construction. See Section R301.1.3, and IBC Section <br /> R107.3.4.1. <br /> Detail for cable-guard does not apply, detail has been removed from Sheet A6. <br /> Additional Comments: <br /> . Wall Type W4 on Sheet A4 is referenced for the existing exterior north wall of the building and <br /> indicates 2x4 stud framing and R-21 insulation. The insulation should be specified as spray- <br /> foam insulation or another insulation type that can achieve the required thermal performance. <br /> Alternatively, the wall should be confirmed to be 2x6 stud framing similar to the other walls. <br /> See Section R106.1.1. <br /> a. Existing walls are confirmed to be 2x6. Detail updated. <br /> Structural <br /> 1. This comment has not been addressed. The proposed project includes structural work. The <br /> overlay of structural information on the architectural plans is not sufficient to specify the <br /> proposed structural work. In addition, the framing appears to be incomplete, including but not <br /> Page 2of6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.