My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10025 19TH AVE SE 201 EVERETT DENTAL CLINIC 2023-12-28
>
Address Records
>
19TH AVE SE
>
10025
>
EVERETT DENTAL CLINIC
>
10025 19TH AVE SE 201 EVERETT DENTAL CLINIC 2023-12-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2023 3:05:45 PM
Creation date
12/21/2023 11:43:00 AM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
10025
Unit
201
Tenant Name
EVERETT DENTAL CLINIC
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Drew Martin <br /> From: Drew Martin <br /> Sent: Tuesday, September 7, 2021 10:59 AM <br /> To: sumeet mittal <br /> Subject: RE: [EXTERNAL] Re: Building Queries <br /> Good morning, Sumeet. <br /> The drawings provided should be sufficient for the proposed work with some edits as follows: <br /> 1. Vicinity Map: Remove bullets at the top of the page and provide a succinct project scope summery, such as: <br /> "Perform interior remodel of existing space to convert from a dental lab to a dental office. Demolition and <br /> construction of interior non-bearing walls only within suite. Other work includes...Jif applicable)." <br /> 2. Site Plan: Fix the note for the "Area of Work" and state it occurs at the second floor. Specify the suite <br /> number. <br /> 3. Project Data: Edit the "Building Code" information to state "2018 IBC'. <br /> 4. Key Plan: This can be kept of removed as it is somewhat redundant with the Site Plan and other plans below <br /> it. If kept,the following should be edited: <br /> a. The plan is distorted. The image should be fixed. <br /> b. The plan appears to include information and notes from the previous project from which is was <br /> obtained. All old notes should be removed (e.g.,work on cabinets and plumbing in the adjacent <br /> suite to the north, etc.). <br /> 5. Existing Plan: Edit as follows: <br /> a. The plan is distorted. The image should be fixed. <br /> b. The plan appears to include information and notes from the previous project from which is was <br /> obtained. All old notes should be removed (e.g.,work on cabinets and plumbing in the adjacent <br /> suite to the north, etc.). <br /> c. The plan should indicate walls to be demolished. <br /> 6. Final Design: Edit as follows: <br /> a. Show all work in Black and White. Solid or infilled walls are recommend for new wall <br /> construction. Bold lines that standout relative to existing work(e.g., light lines, "grey-scale", etc.) <br /> are acceptable drafting standards also. <br /> b. Show walls to be demolished on the Existing Plan. Note that egress paths are not clear, such as the <br /> east-most patient room that does not clearly have a doorway. <br /> c. Show the minimum clearances for all hallways and doorways. See IBC Chapter 10 the minimum <br /> width requirements. <br /> d. The offices have built-in furnishings. These rooms should comply with accessibility requirements of <br /> ICC A117.1-09, including but not limited to turn-around and doorway clearances. <br /> e. Clarify the "PAN" room at the east end;this appears to be imaging equipment. This does not appear <br /> to have sufficient clearance for accessibility requirements. A minimum 5-foot turn-round should be <br /> provided. <br /> f. Verify that the restroom has not been modified. <br /> g. A detail should be provided for the new interior wall construction, including but not limited to top <br /> and bottom connections. The walls and connections should be designed for a minimum out-of- <br /> plane load of 5 psf. <br /> h. A reflected ceiling plan is not provided. Note that this may not be necessary if a grid ceiling is being <br /> modified. It is anticipated that other systems such as ventilation and sprinklers will need to be <br /> modified. A fire alarm system must also be modified if present. <br /> Please let me know if you have questions. <br /> i <br />
The URL can be used to link to this page
Your browser does not support the video tag.