Laserfiche WebLink
Store No.: QFC852 DESIGN AMBIENT: 85 DATE Fl DATE • <br /> KMA:QFC VOLTAGE 460V/3PH BY:E RUWE 11/7/22 WA 0 <br /> IB1:K.: ,_RUWE 11/30/22 WA) 1 <br /> DISTRIBUTED UNIT INFORMATION `/ <br /> CASE/COIL ePRO EVAP LOAD CON- DEFROST TOTAL SUCT PERCENT <br /> UNIT CKT L W H MODEL DESCRIPTION DEPT STAT ITEM TEMP (MBH) TROL #/DAYI TYPE REFRIG LOAD COMPRESSOR HP TEMP CAPACITY THR LOADED Il 03 <br /> W <br /> I- <br /> 1 R448A NEW DISTRIBUTED UNIT Without Sound Attenuation Kit � 5 <br /> • <br /> REMOTE HEADER"A/AR" Reclaim:Water,See RISD-12B,Ship Loose 3-Way Reclaim Valve • U) <br /> 1 Al 12 24 8 EXIST COIL(S) FREEZER GROC. EX -22 23.9 EVR GAS Controller.Danfoss AK-SM 8 11 80A 6 = N <br /> 2 A2 1 QTY RLN(IC-G-LED)-3 3 DOOR G.D.,ICE CREAM TEMP,NARROW BAK. EX -19 3.5 EVR 1 GAS/TIME Control Voltage:208V Cl j o <br /> 3 A3 2 OW FW(DT-E)-12 12'WIDE ISLAND,DUAL TEMP MEAT EX -20 12.6 EVR 1 ELITEMP Control Valve Voltage:208V �I •�' O a, <br /> 2 OW FWE(DT-E) WIDE ISLAND END,DUAL TEMP MEAT EX -20 4.2 1 ELITEMP Compressor Voltage:460VCrie�1 Lu Z <br /> 4 A4 4 QTY RLN(LT-G-LED2)-5 5 DOOR G.D.,LOW TEMP,NARROW GROC. EX -11 19.1 (S)ORIT 1 GAS/IiME `Condenser to be fed from distributed unit ° O <br /> 1 QTY RLN(LT-G-LED2)-3 3 DOOR G.D.,LOW TEMP,NARROW GROC. EX -11 2.9 1 GAS/11ME ""New remote header w/receiver provided by Kysor Warren, Z ~ <br /> 5 A5 2 CITY RLNI(IC-G-LED2)-5 5 DOOR G.D.,ICE CREAM TEMP,NARROW,BACK-TO-BACK GROC. EX -19 9.7 1 GAS/TIME To be fed from building electric > Z <br /> 2 QTY RLN(IC-G-LED2)-2 2 DOOR G.D.,ICE CREAM TEMP,NARROW GROG. EX -19 4.3 1 GAS/TIME "'OEM to ship loose 3-way split condensing valve F-1 . < = <br /> A5A 1 QTY RLN(LT-G-LED2)-5 5 DOOR G.D.,LOW TEMP,NARROW SEAF. EX -11 4.8 1 GAS/TIME _ <br /> - COMBO CIRCUIT EVR Suction Temperature:-25°Midpoint,-21.9°Dewpoint(8.7 PSIG Setpoint) 1.-4 c <br /> 6 A6 4 OW RLNI(LT-G-LED2)-5 5 DOOR G.D.,LOW TEMP,NARROW,BACK-TO-BACK GROC. EX -11 17.3 SORIT 1 GAS/TIME Condensing Temperature:97°Midpoint <br /> 1 ON RLNI(LT-G-LED2)-3 3 DOOR G.D.,LOW TEMP,NARROW,BACK-TO-BACK GROC. EX -11 2.6 1 GAS/TIME cc Z <br /> 7 A7 2 QTY RLNI(IC-G-LED2)-5 5 DOOR G.D.,ICE CREAM TEMP,NARROW,BACK-TO-BACK GROC. EX -19 9.7 EVR 1 GAS/TIME ZFD41K5E Digital,Economized 50° 47.8 74.8 r' rn W <br /> - 1 QTY RLNI(IC-G-LED2)-3 3 DOOR G.D.,ICE CREAM TEMP,NARROW,BACK-TO-BACK GROC. EX -19 2.9 1 GAS/TIME ZF41K5E Economized 50° 47.8 74.8 <br /> 2 OW RLN(IC-G-LED2)-2 2 DOOR G.D.,ICE CREAM TEMP,NARROW GROC. EX -19 4.3 1 GAS/TIME ZF41K5E Economized 50° 47.8 74.8 <br /> 8 A8 2 OW OMZD-5 SINGLE DECK BAK. EX -17 3.9 EVR 2 EUTEMP <br /> 9 A-SP1 SPARE 125.5 143.3 224.4 87.6% <br /> REMOTE HEADER"A/AR" Suction Temperature:18°Midpoint,21.6°Dewpoint(46.2 PSIG Setpoint) <br /> 10 AR9 1 QTY M5XEP(LED)-12 12'FIVE DECK MEAT EX 26 16.4 EVR 4 OT/TIME Condensing Temperature:97°Midpoint =mot <br /> 1 QTY M5XEP(LED)-8 8'FIVE DECK MEAT EX 26 10.9 4 OT/TIME <br /> 11 AR10 2 QTY MSXEP(LED)-8 8'FIVE DECK MEAT EX 26 21.8 EVR 4 OT/TIME ZB114K5E 130.1 172.7 'STAMP: <br /> 12 AR11 2 QTY C2(X)LGEP(M)-12 12'MULTI-DECK,48"HIGH BACK,LOW FRONT,W/G(FRESH MEAT) MEAT EX 23 14.3 EVR 2 OT/TIME ZB114K5E 130.1 172.7 <br /> 13 AR13 1 QTY C2XXLGEP(M)-6 6'MULTI-DECK,LOW FRONT,WIG(FRESH MEAT) SEAF. EX 23 5.1 EVR 2 OT/TIME ZBD114K5E Digital 135.0 176.3 <br /> 14 AR15 8 8 8 EXIST COILS) COOLER SEAF. EX 20 6.9 EVR GAS <br /> 15 AR16 12 40 8 EXIST COIL(S) COOLER MEAT EX 20 26.9 EVR GAS 377.8 395.2 521.7 95.6% 1 <br /> 16 AR17 1 QTY ESBDS-8 8'SERVICE DELI. EX 20 2.8 EX @ CASE 2 OT/TEMP <br /> 1 OW ESBDS-12 12'SERVICE DELI. EX 20 4.3 2 OT/TEMP <br /> AR17A 1 OW SSFO-12R 12'OPEN SERVICE FISH SEAF. EX 24 5.4 EX @ CASE 4 OT/TIME <br /> AR17B 1 OW ESGMS-12 12'SERVICE MEAT EX 22 3.2 EX @ CASE 1 OT/IiME <br /> COMBO LOOP BV @ HEADER REVISIONS <br /> REMOTE HEADER"B" DATE DESCRIPTION <br /> '71 B18 3'-6" 12 8 EAST COIL(S) COOLER MEAT EX 29 8.6 EX @ CASE OT <br /> B21 7 QTY DDSXLP-12 12'FIVE DECK WITH DOORS DELI. EX 32 22.8 EX @ CASE 1 OT/TIME <br /> 1 QTY DD5XLP-4 4'FIVE DECK WITH DOORS DELI. EX 32 1.1 1 OT/TIME <br /> COMBO LOOP BV @ HEADER <br /> 2 B22A 2 QTY IM-04-E5(DELI) MULTI-DECK SELF SERVICE END DELI. EX 28 6.9 EX @ CASE 6 OT/TIME <br /> 1 OW IM-04-C8-R(DELI) 8'UNITIZED MULTI-DECK ISLAND DELI. EX 28 11.0 6 OT/TIME <br /> B22B 2 CITY IM-04-E5(DELI) MULTI-DECK SELF SERVICE END DELI. EX 28 6.9 EX @ CASE 6 OT/TIME <br /> 1 QTY IM-04-C8-R(DELI) 8'UNITIZED MULTI-DECK ISLAND DELI. EX 28 11.0 6 OT/TIME <br /> B22C 2 OW DD5XLP-8 8'FIVE DECK WITH DOORS DELI. EX 32 4.3 EX @ CASE 1 OT/TIME <br /> B23 12 9 8 EXIST COIL(S) COOLER DELI. EX 26 8.6 EX @ COIL <br /> COMBO LOOP BV @ HEADER <br /> 3 B27 28 16'-6" 8 LCA6160S 1/2 COOLER W/(11)DOORS DAIRY EX 26 18.8. EX @ COIL <br /> LCA6160S 1/2 COOLER W/(11)DOORS DAIRY EX 26 18.8 <br /> B28 1 CITY DDSXLP-6 6'FIVE DECK WITH DOORS DAIRY EX 32 1.6 EX @ CASE 1 OT/TIME <br /> 2 OW DD5XLP-12 12'FIVE DECK WITH DOORS DAIRY EX 32 6.5 1 OT/TIME m <br /> B30 11 32 8 EXIST COIL(S) COOLER PROD. EX 26 21.6 EX @ COIL Gi co <br /> COMBO LOOP BV @ HEADER w N <br /> 4 B31 40 FT DMZ(GL DR) VERTICAL SHELF,GL DR RETROFIT DAIRY EX 32 15.0 EX @ CASE o <br /> ' B33 3 Y DSXLEP-12 12'FIVE DECK,LOW FRONT PROD. EX 26 45.5 EX @ CASE 3 OT/TIME a o ` (5)QT <br /> 1 QTY D5XLEP-6 6'FIVE DECK,LOW FRONT PROD. EX 26 7.6 3 OT/TIME a LO a`) <br /> 1 QTY DSXLEP-4 4'FIVE DECK,LOW FRONT PROD. EX 26 5.1 3 OT/TIME ~ CO LU <br /> B34 2 QTY BLF-59SR SELF SERVICE BAK. EX 20 11.3 EX @ CASE 4 OT/TIME w U o <br /> B35 1 QTY BLF-59R SERVICE BAK. EX 20 3.3 EX @ CASE 4 OT/TIME i3 LL 0 sp <br /> lL <br /> B36 1 QTY FLSNX-LEP-8 8'MULTI DECK,LOW FRONT,NARROW FLOR. EX 28 10.6 EX @ CASE 3 OT/TIME ° <br /> 5 B39 4 OW DDSXLP-12 12'FIVE DECK WITH DOORS BEV. EX 32 13.0 SORIT 1 OT/TIME <br /> - 6 B-SP1 SPARE . <br /> 7 B-SP2 SPARE <br /> 8 B-SP3 SPARE _ z <br /> Z m <br /> m w <br /> ;o <br /> TOTAL THR: 746.2 ,, NE <br /> ow wg <br /> NEW 460V Air Cooled Condenser a Zg c F i ,N <br /> BOHN BNH D10 A088(10 FPI), 86.24 mbh/deg td capacity,56 circuits g o a`"a° I + ' <br /> 12 Degree Set Point/Operating ID <br /> 'BxEET NUMBER. <br /> NEMA 1 VFD:Danfoss 178U2584(K-0060172) R2.0 <br /> CITY EVERETT Refrigeration <br /> E a �� Schedule <br /> y ) LP <br />