My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9634 19TH AVE SE B 2024-01-08
>
Address Records
>
19TH AVE SE
>
9634
>
9634 19TH AVE SE B 2024-01-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/8/2024 3:21:05 PM
Creation date
12/22/2023 7:24:52 AM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
9634
Unit
B
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
61
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Rough-In/Cover Inspection <br />Head Placement and Piping: <br />PASS FAIL N/A <br />1. Approved Plans- Approved plans on site? And all work completed Per plans? <br />❑ ❑ ❑ <br />2. Visual Inspection- All piping and components, Including sprinkler heads, hangers, <br />❑ ❑ ❑ <br />valves, and gauges are required to be in place and shall be exposed for visual <br />inspection. If insulation is to be used for freeze protection, this shall be in place <br />and fastened, and with the approval of the inspector, is permitted to cover the <br />necessary exposed pipe. <br />3. Head Placement -Verify proper placement of sprinkler heads and piping to ensure <br />❑ ❑ ❑ <br />installation is according to the approved plans and/or the designed spacing of the <br />heads. (Revised drawings should not be required for minor field changes.) <br />4. Compatibility- When work with CPVC special consideration is necessary when in <br />❑ ❑ ❑ <br />contact with other materials or chemicals. (See manufacturer's guidance on <br />installation and compatible materials.) <br />5. Sprinkler Cabinets- All sprinkler riser assemblies shall be located in a wall, <br />❑ ❑ ❑ <br />cabinet, or other enclosure (with a minimum twelve inch (12") wide by thirty-six <br />inch (36") high access door), unless otherwise approved by the fire code official. <br />(See Diagram) <br />6. Warning Sign - A warning sign, with minimum Y in.(6 mm) letters, shall be affixed <br />❑ ❑ ❑ <br />adjacent to the main shutoff valve and shall state the following: <br />WARNING: The water system far this home supplies fire sprinklers that require <br />certain flows and pressures to fight afire. Devices that restrict the flow or decrease <br />the pressure or automatically shut off the water to the fire sprinkler system, such <br />as water softeners, filtration systems, and automatic shutoff valves, shall not be <br />added to this system without a review ofthe flre sprinkler system by a fire <br />protection specialist. Do not remove this sign. <br />T. Shut Off Valve- A single control valve arranged to shut off both the domestic <br />❑ ❑ ❑ <br />system and the sprinkler system shall be installed. See Passive-purge/Flow <br />Through Riser Detail below. <br />8. Pressure Gauge&Drain - All systems shall be provided with a pressure gauge and <br />❑ ❑ ❑ <br />a 1/2" ball valve system drain to outside. <br />9. Connections to Toilets- All Flow through systems shall be provide with a minimum <br />❑ ❑ ❑ <br />of a 1/2" line to connect to a minimum of 2 toilets, at least one toilet per floor. <br />Fire Marshal's Office 1 42525761101 evereltwa.gov/fire I INFORMATION HANDOUT C 7 14.2020201 Paget <br />