My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1728 100TH ST SW 2024-01-04
>
Address Records
>
100TH ST SW
>
1728
>
1728 100TH ST SW 2024-01-04
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/4/2024 11:04:39 AM
Creation date
12/27/2023 7:10:16 AM
Metadata
Fields
Template:
Address Document
Street Name
100TH ST SW
Street Number
1728
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
193
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Residential Building Air Leakage Test (Blower Door Test) Results <br />Permdp:80"��7—Vi 1 ��'1i f�,. <br />House address w llottnnnuummbbeer.. /-)d`g 100-rP�'ST/,`Sj <br />City: GVE2e./ / Zip: 982og r.� <br />Cand. Floor Area (ft ): �.� F �Age of house: A ) N <br />Source (circle one): Plans Estimated Measured <br />Results shall be reported as Air Changes per Hour at 50 Pascals (ACHeo) and shall be calculated as follows: <br />ACHaa = (CFM50 x 60Y Volume <br />Where: <br />CFM50 = Blower door fan flaw at 50 Pascal pressure difference <br />Volume = Conditioned Fluor Area of the housing unit at ceiling height <br />Blower Door Test Resuk: 3.0 ACHa <br />/ &M CFM@50Pa <br />Fling (circle one if applicable): ,Open <br />Blower Dow Fan hocellon: AAAGr L qj WYeoher Conditions: �e <br />00 <br />I ceri fy that these blower door nsuaMs are aacwrMe and determined using standard Indus" <br />prokrol. <br />Company Name: FopzeS l ls-u4 Technician: T Fd�1eJ <br />Technician Signature: f' \Date: 7- d s�a31phone Number: W6-ID'`p <br />2015 Washington State Energy Code refarence: <br />R402A.1.2 Tesfigg. The building or dwelling wit shag be used and verified as having av air leakage rate of not <br />exceeding 5 air changes per hour. Testing shall be conducted with a blower door at a pressure of0.2 inches w.g. (50 <br />Pascals). Where required by the code official, testing shell be conducted by an ap➢roved third party. A written report <br />of the results of the test shelf be signedb the party camaluctine the tat and Providam!WWe eodeo dal. Testing <br />shall be performed at my time after creation of all penetration of the building thermal envelope. Once visual <br />inspection has confirmed scaling (sec Table R402A.1.1), operable windows and dwrs manufactured by small business <br />shag be permitted in be saled otpat the flame prior to the test <br />
The URL can be used to link to this page
Your browser does not support the video tag.