My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1728 100TH ST SW 2024-01-04
>
Address Records
>
100TH ST SW
>
1728
>
1728 100TH ST SW 2024-01-04
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/4/2024 11:04:39 AM
Creation date
12/27/2023 7:10:16 AM
Metadata
Fields
Template:
Address Document
Street Name
100TH ST SW
Street Number
1728
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
193
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr. Rakeeb Khan <br />October 26, 202� <br />Page 3/ p� ) <br />R312.1. The guards, connections to the supporting framing, and the supporting framing should <br />be designed to resist a minimum 200-pound load per Table R301.5. <br />Standard deck post connection detail added to the supplemental details. <br />5. The structural calculations do not include calculations for the lateral design of the covered <br />deck. <br />Calculations substantiating the design should be submitted for review. Lateral loads should be <br />transferred to the ground or to a structure capable of transmitting them to the ground. See <br />Section R507.9.2 for more information. R301.1.3 <br />Lateral anchor callout added to plan view and detail added to the supplemental details in <br />accordance with IRC Section R507.9.2 <br />6. Details of the gable end roof condition should be provided. Detail should specify bracing <br />requirements to resist out -of -plane loading (e.g., wind) on the wall if the wall is not continuous <br />between the floor and roof sheathing. This is not provided by the manufacturer. Note that <br />truss stability bracing provided by the manufacturer is not intended for this purpose. See <br />Sections R106.1.1 and R602.3. <br />Supplemental structural details added including the gable end wall bracing <br />7. Structural special inspections may be required for this project (shear wall nailing closer than <br />4 inches). A statement on special inspections has not been provided and should be provided on <br />the plans. The statement should include a table listing each type of special inspection and <br />should specify the extent of each inspection (e.g., continuous, periodic) per IBC Section <br />1704.3.1. The table should include special requirements for seismic and wind resisting systems <br />as required by IBC Sections 1704.3.2 and 1704.3.3, respectively. See IBC Sections 107.1, <br />1704.2.3, 1704.3, Table 1705.3. <br />Structural notes, fastener schedule, and special inspection tables added to the end of the planset <br />Please feel free to contact me if you would like to discuss any of these items in more detail or if you <br />have any questions. You can reach me by phone at (206) 914-9536, or by email at <br />LakeviewSE@outlook.com. <br />Sincerely, <br />C <br />11/09/22 11 01 AM <br />