My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1728 100TH ST SW 2024-01-04
>
Address Records
>
100TH ST SW
>
1728
>
1728 100TH ST SW 2024-01-04
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/4/2024 11:04:39 AM
Creation date
12/27/2023 7:10:16 AM
Metadata
Fields
Template:
Address Document
Street Name
100TH ST SW
Street Number
1728
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
193
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2018 Washington State Energy Code — Residential <br />Prescriptive Energy Code Compliance for All Climate Zones in Washington <br />Single Family — New & Additions (effective February 1, 2021) <br />These requirements apply to all IRC building types, including detached one- and two-family <br />dwellings and multiple single-family dwellings (townhouses). <br />Project Information Contact Information <br />A & P Holdings Marie Anderson A Nash & Asso Architects <br />79th PI. NE, Granite Falls (425) 242-7491 marie@Nash-Architects.com <br />Instructions: This single-family project will use the requirements of the Prescriptive Path below and <br />incorporate the minimum values listed. Based on the size of the structure, the appropriate number of <br />additional credits are checked as chosen by the permit applicant. <br />Provide all information from the following tables as building permit drawings: Table R402.1- Insulation and <br />Fenestration Requirements by Component, Table R406.2 - Fuel Normalization Credits and 406.3 - Energy Credits. <br />Authorized Representative Date 104113/2021 <br />All Climate Zones (Table R402.1.1) <br />R-Value 0 <br />U-Factor' <br />Fenestration U-Factor b <br />n/a <br />0.30 <br />Skylight U-Factor b <br />n/a <br />0.50 <br />Glazed Fenestration SHGC e e <br />n/a <br />n/a <br />Ceiling " <br />49, <br />0.026 <br />Wood Frame Wall g,h <br />21 int <br />0.056 <br />Floor <br />30 <br />0.029 <br />Below Grade Wall `•h <br />10/15/21 int +TB <br />0.042 <br />Slab d,' R-Value & Depth <br />10, 2 ft <br />n/a <br />R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity that is less <br />a than the label or design thickness of the insulation, the compressed R-value of the insulation from Appendix <br />Table A101.4 shall not be less than the R-value specified in the table. <br />b The fenestration U-factor column excludes skylights. <br />"10/15/21 +5TB" means R-10 continuous insulation on the exterior of the wall, or R-15 continuous insulation on <br />the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the basement wall at <br />c the interior of the basement wall. "10/15/21 +5TB" shall be permitted to be met with R-13 cavity insulation on <br />the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall. "5TB" <br />means R-5 thermal break between floor slab and basement wall. <br />d R-10 continuous insulation is required under heated slab on grade floors. See Section R402.2.9.1. <br />e <br />For single rafter- or joist -vaulted ceilings, the insulation may be reduced to R-38 if the full insulation depth <br />extends over the top plate of the exterior wall. <br />R-7.5 continuous insulation installed over an existing slab is deemed to be equivalent to the required perimeter <br />f slab insulation when applied to existing slabs complying with Section R503.1.1. If foam plastic is used, it shall <br />meet the requirements for thermal barriers protecting foam plastics. <br />For log structures developed in compliance with Standard ICC 400, log walls shall meet the requirements for <br />9 climate zone 5 of ICC 400. <br />Int. (intermediate framing) denotes framing and insulation as described in Section A103.2.2 including standard <br />h framing 16 inches on center, 78% of the wall cavity insulated and headers insulated with a minimum of R-10 <br />insulation. <br />V9 � U [ E <br />MAR 0 6 2023 <br />Prescriptive Path — Single Family 2018 Washington State Energy Code-R 0 <br />CITY OF EIVERETT <br />Permit Services <br />
The URL can be used to link to this page
Your browser does not support the video tag.