My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
222 W CASINO RD 2023-12-28
>
Address Records
>
W CASINO RD
>
222
>
222 W CASINO RD 2023-12-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2023 10:46:59 AM
Creation date
12/27/2023 8:40:18 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
222
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
a <br /> NOTES: Lp <br /> CD <br /> GENERAL: cl) <br /> 1. ALL NEW FACILITIES SHALL BE BUILT IN ACCORDANCE WITH ACCESSIBILITY N <br /> REQUIREMENTS FOR BARRIER FREE ACCESS (WAC-51-50-1100). N <br /> 2. ALL STAIRS, RAMPS, LANDINGS, AND HANDRAILS TO BE SUPPLIED AND rn <br /> INSTALLED ON SITE BY OTHERS, UNDER SEPARATE LOCAL PERMIT(UNLESS c9 <br /> NOTED OTHERWISE) L <br /> BUILDING ENVELOPE: CODE ANALYSIS1. CODE REFERENCES BELOW REFER TO THE WASHINGTON STATE ENERGY KCDA 12'x 25' MODULAR RESTROOM THIS STRUCTURE MEETS CONSTRUCTION REQUIRMENTS OF 2018 IBC AND 2018 <br /> CODE (WSEC)2018 EDITION. � <br /> WSEC.AS AMENDED FOR WASHINGTON STATE GOLD LABEL INSIGNIAS. <br /> J <br /> 2. INSULATION SHALL BE PROVIDED WITH A R-VALUE IDENTIFICATION MARK <br /> FROM THE MANUFACTURER, MARK SHALL BE VISIBLE DURING INSPECTION <br /> (WSEC C303.1.1 &C303.1.2) BUILDING TYPE: VB <br /> 3. ALL INSULATION MATERIALS SHALL BE INSTALLED PER MANUFACTURES OCCUPANCY GROUP: B DESIGN LOADS <br /> INSTRUCTIONS TO MAINTAIN PROPER DENSITIES, MAINTAIN CLEARANCES, RISK CATAGORY: II ROOF LIVE: 30psf <br /> AND OBTAIN FULL R-VALUE (WSEC C303.2).WHERE TWO OR MORE LAYERS BUILDING USE: RESTROOM PONDING: N/A <br /> OF RIGID INSULATION WILL BE USED, EDGE JOINTS SHALL BE STAGGERED BUILDING AREA: 295.8 SQ. FT. <br /> BETWEEN LAYERS (WSEC C402.2.1) FLOOR LIVE: <br /> 4. ROOF/CEILING INSULATION SHALL BE INSTALLED W/MIN 1" CLEAR AIR SPACE NUMBER OF OCCUPANTS (IBC TABLE 1004.1.2) RESTROOM: 40ps <br /> TO ROOFING MEMBERS ABOVE. WHEN EAVE VENTING IS REQUIRED INSTALL (AREA/FLOOR AREA PER PERSON) N/A: N/A <br /> BAFFLES TO DEFLECT AIR OVER SURFACE OF INSULATION. (IBC 1203.2) RESTROOM: / 2 N/A: N/A <br /> 5. WHERE TWO OR MORE LAYERS OF RIGID INSULATION ARE USED, EDGE N/A: -- / -- -- N/A: N/A <br /> JOINTS BETWEEN LAYERS SHALL BE STAGGERED (WSEC C402.2.1) N/A: -- / -- -- CONCENTRATED 30"SQ.1,000psf <br /> 6. MAXIMUM GLAZING AREA SHALL NOT EXCEED 30 PERCENT OF GROSS ABOVE N/A: -- / -- -- <br /> GRADE WALL AREA(SKYLIGHTS SHALL NOT EXCEED 3 PERCENT OF GROSS TOTAL OCCUPANTS: 2 WIND LOAD: 120 <br /> ROOF AREA)(WSEC C402.4.1).AREA MAY BE INCREASED TO 40 PERCENT IF EXPOSURE: B <br /> PROVISIONS OF WSEC C402.4.1.1 ARE FOLLOWED. <br /> 7. EXTERIOR WALL CAVITIES SHALL BE FULLY INSULATED TO THE LEVELS OF ENERGY CODE: 2018 WSEC SEISMIC DESIGN REQUIREMENTS: <br /> THE SURROUNDING WALLS. COMPLIANCE COMP. PERF. DESIGN CATEGORY: D <br /> 8. FLOOR INSULATION SHALL BE INSTALLED IN A PERMANENT MANNER IN CLIMATE ZONE: 4C DESIGN Sds: 0.701 <br /> SUBSTANTIAL CONTACT WITH THE SURFACE BEING INSULATED. SUPPORTS GLAZING PERCENTAGE : DESIGN Ss: 0.933 <br /> SHALL BE SPACED AT NOT MORE THAN 24"O.C. INSULATION SHALL NOT GLAZING AREA/GROSS WALL AREA <br /> BLOCK CRAWL SPACE VENTS. ® 0 / 626 = 0.0% <br /> 9. DOOR AND GLAZING U-FACTOR, SHGC&VT SHALL BE OBTAINED FROM NFRC <br /> LABEL, PRODUCTS LACKING THIS LABEL SHALL BE ASSIGNED A DEFAULT NOTES: <br /> VALUE FROM WSEC TABLES IN CHAPTER 3(WSEC C303.1.3 & C402.4.3) 1. REFER TO PLAN AND SECTIONS FOR INSTALLED INSULATION VALUES <br /> 10. VAPOR BARRIER (CLASS I OR II) REQUIRED AT WARM SIDE OF WALL 2. THIS BUILDING COMPLIES WITH WSEC SECTION C406"ADDITIONAL EFFICIENCY <br /> INSULATION. FOR BUILDINGS IN CLIMATE ZONES: MARINE 4, 5,6,7 &8 (IBC CREDIT REQUIREMENTS". PER TABLE C406.1 BUILDING SHALL COMPLY WITH A <br /> 1405.3) MINIMUM OF SIX CREDITS. <br /> 11. A CONTINUOUS AIR BARRIER SHALL BE PROVIDED, EXTERIOR JOINTS COMPLIANCE VIA SELECTED OPTIONS LISTED BELOW: <br /> AROUND WINDOWS& DOOR FRAMES, EXTERIOR PENETRATIONS, JOINTS 3. REDUCED LIGHTING POWER IN ACCORANCE WITH SECTION C406.3 <br /> BETWEEN BUILDING COMPONENTS AND ANY OTHER OPENINGS, JOINTS AND 4 CREDITS (REFER TO SHEET E-0.0) <br /> OR CRACKS IN THE BUILDING ENVELOPE SHALL BE SEALED, GASKETED, 4. ENHANCED LIGHTING CONTROLS IN ACCORDANCE WITH SECTION C406.4 <br /> CAULKED OR WEATHERSTRIPPED TO LIMIT AIR LEAKAGE. (WSEC C402.5.1.1 & 1 CREDIT (REFER TO SHEET E-1.0) <br /> C402.5.1.2) 6.DEDICATED OUTDOOR AIR SYSTEM IN ACCORDANCE WITH SECTION C406.6 <br /> 12. BUILDING ASSEMBLIES USED AS DUCTS OR PLENUMS SHALL BE SEALED, 4 CREDITS (REFER TO SHEET E-1.0) <br /> CAULKED AND GASKETED TO LIMIT AIR LEAKAGE. <br /> 13. OUTSIDE AIR AND RELIEF DAMPERS SHALL COMPLY WITH WSEC J TOTAL: 9 CREDITS <br /> C403.2.4.3.OUTS IDE AIR DAMPERS SHALL BE MOTORIZED AND SHALL CLOSE <br /> AUTOMATICALLY WHEN THE SYSTEM IS OFF AND HAVE A LEAKAGE <br /> RATE OF MAX 4CFM/SF. GRAVITY RELIEF DAMPERS MAY BE USED ON <br /> BUILDINGS WITH LESS THAN 5,000 CFM TOTAL SUPPLY FLOW. GRAVITY SHEET INDEX <br /> DAMPERS WHEN PERMITTED SHALL HAVE A LEAKAGE RATE OF 20CFM/SF <br /> (40CFM/SF IF LESS THAN 24") <br /> 14. AIR BARRIER SHALL BE TESTED ON SITE BY OTHERS (NIC).AIR BARRIER TEST SHEET NO. SHEET NAME <br /> SHALL BE IN ACCORDANCE WITH ASTM E779 OR APPROVED EQUIVALENT. A-0.0 COVER SHEET <br /> MAXIMUM AIR LEAKAGE SHALL BE 0.40 CFM/SQFT AT A PRESSURE A-1.0 FLOOR PLAN <br /> DIFFERENTIAL OF 0.3 INCHES WATER GAUGE. AIR BARRIER TEST RESULTS TO A-2.0 EXTERIOR ELEVATIONS <br /> BE SUBMITTED TO THE LOCAL BUILDING OFFICIAL. IF TEST RESULTS EXCEED <br /> 0.4 CFM/SQFT THEN VISUALLY INSPECT AIR BARRIER AND SEAL NOTED A-3.0 INTERIOR ELEVATIONS <br /> SOURCES OF LEAKAGE. SUBMIT A FOLLOW UP REPORT NOTING E-0.0 ELEC/MECH COVER <br /> CORRECTIVE MEASURES TAKEN, INCLUDE ALL TESTING AND COMPLIANCE E-1.0 ELEC/MECH/RCP <br /> DOCUMENTATION TO THE BUILDING OWNER. (WSEC C103.2&C402.5.1.2) P-1.0 PLUMBING <br /> STRUCTURAL: S-1.0 STRUCTURAL PLAN <br /> 1. WINDOWS AND DOORS SHALL HAVE A MIN OF (2)STUDS AT EACH SIDE (1 S-2.0 SECTION & DETAILS <br /> KING STUD AND ONE TRIMMER) TOTAL: 9 <br /> 2. ALL NAILING AND FASTENING NOT CALLED OUT ON PLANS AND DETAILS <br /> SHALL BE PER IBC 2304.10 NAILING SCHEDULE (LOCATED ON THIS SHEET OR <br /> STRUCTURAL PLAN SHEET) L&I APPROVAL STAMP <br /> ABBREVIATIONS <br /> N.B.W. NOT PROVIDED OR INSTALLED BY WHITLEY <br /> (PROVIDED AND INSTALLED BY OTHERS ON SITE) <br /> OFCI OWNER FURNISHED, CONTRACTOR INSTALLED <br /> (PROVIDED BY OWNER AND INSTALLED ON SITE BY OTHERS) <br /> OFWI OWNER FURNISHED, WHITLEY INSTALLED <br /> (PROVIDED BY OWNER AND INSTALLED IN FACTORY BY WHITLEY) <br /> N.L.E.A.NOTICE TO LOCAL ENFORCEMENT AGENCY <br /> (ITEMS THAT ARE INSTALLED OR COMPLETED ON SITE, TO BE INSPECTED <br /> BY LOCAL BUILDING OFFICIAL). <br /> T.B.D. TO BE DETERMINED <br /> WEI WHITLEY EVERGREEN INC. <br /> NIC NOT IN CONTRACT <br /> NOTE: TEXT IN ITALICS REFERS TO WORK OR ITEMS TO BE INSTALLED ON SITE, OR <br /> OTHERWISE NOT IN THE FACTORY SCOPE OF WORK <br /> THIS DRAWING AND ALL INFORMATION 14219 CUSTOMER NAME: KC DA RELEASE: PROJECT No.: <br /> CONTAINED HEREON IS THE PROPERTY <br /> WHITLEY BLVD., BLDG <br /> No. 10 PERMIT 4533 <br /> OF WHITLEY EVERGREEN INC.,AND IS BLVD., BLDG W 10 PROJECT NAME: 12X25 RESTROOM s/N' 0523-161 <br /> EVERGREEN INCE MARYSVILLE,WA 98271 SHEET No.: <br /> NOT TO BE REPRODUCED WITHOUT THE STD PLAN No: A-0.0 <br /> EXPRESS PERMISSION OF WHITLEYPH. 360.653.5790 PROJECT DESC.: 12X25 MODULAR RESTROOM <br /> 2 PERMIT 06-09-2023 EVERGREEN, INC.WHITLEY EVERGREEN WHITLEY FAX: 360.659.7735 DRAWN BY: MDP DATE: 05-12-2023 <br /> 1 PRELIM 05-12-2023SSESNO USE THIS DRAWING. <br /> RESPONSIBILITY MOBILE AND MODULAR BUILDINGS WWW.WHITLEYMAN.COM SHEET NAME: COVER SHEET REVISED BY: KB <br /> UNAUTHORIZED No. DESCRIPTION DATE BY EVERGREEN CHKD BY: SCALE: 1/4" = 1'-0" <br />
The URL can be used to link to this page
Your browser does not support the video tag.