a <br /> M <br /> NOTES: Branch Panel: MDP <br /> 0 <br /> M <br /> GENERAL: Location: Volts: 120/240 Single A.I.C. Rating: 10000 M <br /> N <br /> Supply From: Phases: 1 Mains Type: BREAKER N <br /> 1. ALL HEIGHT DIMENSIONS SHOWN ON PLAN ARE FROM FINISH FLOOR TO CENTER OF BOX Mounting: SURFACE Wires: 3 Mains Rating: 100 A <br /> UNLESS NOTED OTHERWISE <br /> Enclosure: NEMA 3R MCB Rating: 100 A <br /> 2. ITALICS INDICATES WORK TO BE DONE ON SITE (BY CLIENT UNLESS OTHERWISE NOTED) Q <br /> Notes: CO <br /> 3. SERVICE ENTRANCE IS ON SITE BY CLIENT, WHITLEY TO PROVIDE PANEL, SERVICE CONDUIT o <br /> & INSTALLATION OF FEEDER CONDUCTORS, ALL OTHER SERVICE DISCONNECTS, TRANSFORMERS, <br /> BOXES AND CONDUIT ARE ON SITE BY CLIENT. <br /> 4. ALL ELECTRICAL CONSTRUCTION MEANS AND METHODS SHALL COMPLY WITH NEC 2014 <br /> EDITION, AND WAC 296-46B CKT Circuit Description Trip Poles A B Poles Trip Circuit Description CKT <br /> 5. ALL RECEPTACLES SHALL BE INSTALLED AT 18"AFF UNLESS NOTED OTHERWISE. 1 INT/EXT LIGHTING, EXHAUST FANS 20 A 1 117 VA 1920 VA 1 20 A HEAT TRACE RECEPTACLE (GFEP) 2 <br /> 3 GENERAL RECEPTACLE(3) 20 A 1 540 VA 1650 VA 1 25A WATER HEATER 4 <br /> 6. GROUND FAULT(GFCI) PROTECTION IS REQUIRED FOR ALL RECEPTACLES IN WET AREAS. 5 HEAT RM 101 20 A 2 1500 VA 1500 VA 4 2 20 A HEAT RM 102 6 <br /> EXTERIOR RECEPTACLES SHALL BE WEATHER RESISTANT,AND INSTALLED WITH A IN-USE 7 __ -- -- 1500 VA 1500 VA -- -- -- 8 <br /> COVER. 9 ERVII 15A 1 160 VA 160 VA 1 15 A ERV 2 10 <br /> 7. BUILDING SHALL BE WIRED IN CONDUIT OR MC CABLE 11 Space -- 1 1 -- Space 12 <br /> Total Load: 5351 VA 5190 VA <br /> 8. ALL CONDUCTORS, CONDUITS AND CIRCUITS SHALL BE SIZED TO COMPLY WITH NEC 2020. Total Amps: 45 A 43A <br /> MIN WIRE SIZES. <br /> POWER AND LIGHTING CIRCUITS - MIN. 12 AWG Legend: <br /> BRANCH CIRCUIT HOME RUNS OVER 75 FEET - MIN. 10 AWG <br /> CONTROL WIRING - MIN. 14 AWG <br /> Load Classification Connected Load Demand Factor Estimated Demand Panel Totals <br /> 9. ALL INDICATED WIRE SIZES BASED ON 75 DEGREE EQUIPMENT TERMINAL RATINGS IN ACCORDANCE Equipment 1970 VA 100.00% 1970 VA <br /> WITH NEC 310-16. WHERE EQUIPMENT IS PROVIDED AT LESS THAN 75 DEGREE, CONTRACTOR Heating 6000 VA 100.00% 6000 VA Total Conn. Load: 10541 VA <br /> SHALL PROVIDE PROPER CONDUCTOR SIZE ADJUSTED ACCORDINGLY TO REFLECT EQUIPMENT <br /> RATINGS. Lighting 117 VA 125.00% 146 VA Total Est. Demand: 10569 VA <br /> Other 0 VA 0.00% 0 VA Total Conn.: 44 A <br /> Receptacle 2460 VA 100.00% 2460 VA Total Est. Demand: 44 A <br /> Notes: <br /> 0 <br /> o LIGHTING BUDGET CALCULATIONS <br /> uj <br /> uj <br /> LU NOTE: WHITLEY SCOPE OF WORK IS <br /> X MAXIMUM ALLOWED INTERIOR LIGHTING WATTAGE (SPACE BY SPACE METHOD) <br /> LIMITED TO WITHIN MODULE. <br /> Z <br /> w <br /> MDP EXTENSION OF CONDUIT TO METER/POINT OF SPACE TYPE AREA VA/SF VA ALLOWED <br /> 100 A CONNECTION AND INSTALLATION OF FEEDER <br /> 120/240 CONDUCTORS RESTROOM 232 0.63 146 <br /> 10Kaic ARE ON SITE BY CLIENT UNDER SEPARATE MECH ROOM 11 0.43 4 <br /> LOCAL PERMIT. <br /> NEMA-3R TOTAL VA ALLOWED 150 VA <br /> 100A M.B. <br /> N.L.E.A. LIGHT REDUCTION/REDUCED LIGHTING POWER (PER WSEC C406.1 #2) <br /> I <br /> TOTAL VA ALLOWED x 0.75 = 0.75 x 150 = 113 VA ALLOWED PER <br /> FINISH FLOOR SECTION C408 ADDITIONAL EFFICIENCY OPTIONS <br /> CRAWL SPACE PROPOSED INTERIOR LIGHTING WATTAGE: <br /> _ #8 GND TO COLD <br /> WATER PIPE & (3) LED TROFFERS @ 27 VA 81 <br /> GROUND ROD <br /> 2"C TOTAL PROPOSED INTERIOR LIGHTING VA 81 VA <br /> N.L.E.A. (2) #3 HOT <br /> (1) #6 NEUT. <br /> INCOMING SERVICE FEEDER (1) #8 GND. PERCENTAGE OF INSTALLED INTERIOR LIGHTING CONFIGURED WITH ENHANCED <br /> & CONDUIT BY CLIENT CONTROL FUNCTIONS (WSEC C406.4) <br /> AVAILABLE FAULT CURRENT <br /> LESS THEN 10 Kaic (TOTAL CONTROLLED LIGHTING/TOTAL INSTALLED LIGHTING )* 100 <br /> (81 /81) 100 = 100 % <br /> LIGHTING FIXTURE SCHEDULE MAXIMUM ALLOWED EXTERIOR TRADABLE LIGHTING WATTAGE: <br /> LAMP(S) INPUT PED ENTRANCE WATTS/LF LF VA ALLOWED <br /> MARK QTY DESCRIPTION MFR. MODEL QTY TYPE WATTS BALLAST COMMENTS BLDG ENTRY 21 6 126 <br /> L-1 2 2x4 LAY-IN LED TROFFER, W/ADDRESSABLE CONTROLS CREE ZR24MT-40L-35-SC1 1 LED 27 VA LED DRIVER <br /> L-2 1 1x4 LAY-IN LED TROFFER, W/ADDRESSABLE CONTROLS CREE ZR14MT-40L-35-10V 1 LED 27 VA BASIC SITE ALLOWANCE ZONE 3 500 <br /> L-3 2 EXT. LED LIGHT, WALL MOUNT HARRIS 300-LED 1 LED 18 VA LED DRIVER W/PHOTOCELL <br /> TOTAL VA ALLOWED 626 <br /> MECHANICAL EQUIPMENT SCHEDULE PROPOSED EXTERIOR LIGHTING WATTAGE: <br /> MARK QTY DESCRIPTION MFR. MODEL COMMENTS (2)WALL MOUNT LED FIXTURES @18VA 36 <br /> M-1 4 ELECTRIC WALL HEATER, SEMI RECESSED KING W2415 750 WATT, 240V W/(1)K-102 REMOTE STAT PER ROOM TOTAL PROPOSED LIGHTING VA 36 <br /> M-3 2 135 CFM RANGE @ 0.2 IN.WG, GREENHECK ASSURE 120S-S1 CONTROLLED W/OCC SENSOR, HIGH SPEED SETTING <br /> ENERGY RECOVERY VENTILATOR WITH HIGH EFFICIENCY EC MOTOR <br /> AND PRECISION SYNC AUTO-BALANCING TECHNOLOGY AND SIDE PORTS <br /> THIS DRAWING AND ALL INFORMATION 14219 CUSTOMER NAME: KC DA RELEASE: PROJECT No.: <br /> CONTAINED HEREON IS THE PROPERTY <br /> WWHITLEY BLVD., BLDG <br /> No. 10 PERMIT 4533 <br /> OF WHITLEY EVERGREEN INC.,AND IS BLVD., BLDG W 10 PROJECT NAME: 12X25 RESTROOM S/N' 0523-161 <br /> NOT TO BE REPRODUCED WITHOUT THE MARYSVILLE,WA 98271 STD PLAN No: SHEET No.: <br /> EXPRESS PERMISSION OF WHITLEY EVE RG RE E N , I N C■ PH. 360.653.5790 PROJECT DESC.: 12X25 MODULAR RESTROOME-0.0 <br /> 2 PERMIT 06-09-2023 EVERGREEN, INC.WHITLEY EVERGREEN WHITLEY FAX: 360.659.7735 DRAWN BY: MDP DATE: 05-12-2023 <br /> 1 PRELIM 05-12-2023 MOEDUSEOF THIS DRAWING. EVERGREEN <br /> ASSUES RESPONSIBILITY FOR <br /> MOBILE AND MODULAR BUILDINGS WWW.WHITLEYMAN.COM SHEET NAME: E L E C/M E C H COVER REVISED BY: KB <br /> No. DESCRIPTION DATE BY UNAUHORIZCHKD BY: SCALE: 1/4" = 1'-0" <br />
The URL can be used to link to this page
Your browser does not support the video tag.