Laserfiche WebLink
EZSOLAR JB-1 .2 EZf S O L A R PHONE:385-202-4150 NOI <br /> Specification Sheet ma king solar shall WWW,EZSOLARPRODUCTS.COM <br /> BLUE RAVEN <br /> making Solar Simple, PV Junction Box for Compos ition/Asphalt Shingle Roofs <br /> 1403 N.Research Way <br /> A. System Specifications and Ratings Orem,UT 84097 <br /> Y P 9 ITEM N0. PART NUMBER DESCRIPTION OTY slzE ow0 NO. REV <br /> 800.377.4480 <br /> R WWW.BLUERAVENSOLAR.COM <br /> POLYCARBONATE <br /> • Maximum Voltage:1,000 Volts 1 1B 1.2 BODY 1 J"-1' CONFIDENTIAL-THE INFORMATION <br /> WITH UV INHIBITORS SCALE:1:2 WEIGHT:1.45 LBS SHEET 1 OF 3 HEREIN CONTAINED SHALL NOT BE <br /> Maximum Current:80 Amps USED FOR THE BENEFIT OF ANYONE <br /> Allowable Wire:14 AWG-6 AWG 2 POLYCARBONATE ALLEXCIT BE D SCL SE SOLAR NOR <br /> SHALL IT BE DISCLOSED IN WHOLE OR <br /> c� 1B-12 LID WITH UV INHIBITORS 1 TORQUE SPECIFICATION: 15-20 LBS IN PART TO OTHERS OUTSIDE <br /> • <br /> Spacing::Please maintain a spacing of at least'/2' between uninsulated live arts and fittings for IN CONNEPIENTION WITH ZATION, <br /> EXCEPT <br /> P 9 P 9 P 9 R CONNECTION WITH THE SALE AND <br /> conduit,armored cable,and uninsulated live parts of opposite polarity. #10 X 1-1/4'PHILLIPS UL STANDARD 1741, USE OF THE RESPECTIVE EQUIPMENT, <br /> Enclosure Ratio T e 3R 3 PAN HEAD SCREW B CERTIFICATION: NEMA 3R WIT OFBLUE RAVEN SOLAR T THE WRITTEN MIC. <br /> 9� YP <br /> • LL <br /> Roof Slope Range:2.5-12:12WEIGHT: <br /> 4 #8 X 3/4"PHILLIPS B 1.45 LBS NABCEP <br /> Max Side Wall Fitting Size:1" PAN HEAD SCREW <br /> is Max Floor Pass-Through Fitting Size:1" 1 CERTIFIED <br /> Ambient Operating Conditions:(-35°C)-(+75°C) PV INSTALLATION <br /> PROFESSIONAL <br /> • Compliance: S-nGumey <br /> J13-1.2:UL1741 #PV-011719015866 <br /> Approved wire connectors:must conform to UL1741 CONTRACTOR: <br /> • System Marking:Interek Symbol and File#5019942 BRS FIELD OPS <br /> • Periodic Re-inspections:If re-inspections yield loose components,loose fasteners,or any corrosion 385-498-6700 <br /> between components,components that are found to be affected are to be replaced immediately. <br /> table 11 Tvplol Wilre Sbe,torque Wads and RaIIAW <br /> T <br /> 1 fnnasly t Caearas Tree real W&US Vatae6 Car.6rlt �•�` <br /> Ata/k lww.NMwa IDH 141• 1.UV. 0517 6Jan 111..1 I—P / _ �- <br /> na 2110 bbd 6-:4 I1 10 11111, snlV 1016 ■n 14 16 611 <br /> Jaa2s»4..ww• ala oto tdrv. 161. 1441t14 6av 1A..P • ��� • <br /> ya Knl.s�nr l..w1 s]1 t..u11, aat 6n fi-e Sn a...P �27 IjOlien; '?IOAftill 1n� <br /> lar nJ4..I w111r.6uT W,.. IIAINI IO.Q�rt <br /> .la•ra S.W. %W1._ wit.— nn:': <br /> � •".rr1—WP11.11..11 10Ia-8 s•u51, 5.1 Fs... 5a111n6.• •1KV SOLAR <br /> WMFC,w.—tp <br /> 1a44,In Suar R,lh a• 1014-6 W10, uefsa. WIT.R— 40W <br /> la.w•!s►.1611 )li•12 I <br /> WAW'11041101 1010-4 161aay 1W,'V, y11_ WT.0— 00:': 10..,. <br /> WKA,l]l6ll IDKti 10]a w.a Se+h, w Salltutr.� IO amp <br /> DNtwO1Kh 6114wa 511,`.• Yrrl. <br /> !ta'NGSI 4♦ MUvr a1 l000V <br /> to 14— 1NNr 15 <br /> 1014 Sotto- IS to BY: <br /> 4r—.0a5.1 44 1W1V. 45 � <br /> 10 34-1 I1631,D61T1mi r� J•. 1T� <br /> Min 2AS is PLOT DATE: <br /> Table 2:Minimus wire-berwan8 space foe corldxtces Ovou(h a wall opposite terminals In mm(inches) <br /> — [26S.Ierltml <br /> Wine size,AWG cir wine;per ten bv1 pole IOA4i1 <br /> 12 3 4 or M" PROJECT NUMBER: <br /> ease mm2 mm i mm 111th mm Iwh mm {Holl <br /> 14-30 (2.13.3) Not specified - - - <br /> a 18.41 38.1 n 112) SHEET NAME: <br /> 6 (13.3) 50.8 (2) <br /> SPEC SHEET <br /> REVISION: IPAGE NUMBER: <br /> EZtSOLAR PHONE:385-202-4150 1 WWW.EZSOLARPRODUCTS.COM PROPRIETARY AND CONFIDENTIAL:THE INFORMATION CONTAINED INTHIS DRAWING ISTHE SOLE PROPERTYOF EZ SOLAR. ---- SS <br /> ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUTTHE WRITTEN PERMISSION OF EZ SOLAR IS PROHIBITED. <br />