My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD 2019 BLDG 40-54 Plans 2023-12-28
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-54
>
Plans
>
3003 W CASINO RD 2019 BLDG 40-54 Plans 2023-12-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2023 2:00:59 PM
Creation date
12/28/2023 1:58:38 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-54
Permit
FA1910-004
Year
2019
Notes
EXPAND EXISTING FIRE ALARM TO COVER EXISTING SPRINKLER SYST
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Permits- FA7910-DO4 <br /> Site Address: 3003 W CASINO RD#40-54 <br /> 'Owner.. BOEING COMPANY <br /> NE <br /> Tenant 7enName] <br /> Ap.0-te: 10/10/2019 <br /> L.: <br /> P,p—a Ur <br /> Oe-,IE%PAND IXI5TING 11.A.-E0 O C <br /> IXLSTINGSPRINKLER SYST <br /> BOEING COMMERCIAL AIRPLAGROUP <br /> R✓Office J Ste Set ,OFrel".a in Set <br /> BUILDING 40-054 <br /> NFPA 7"2 <br /> PRETEST PAPERWORK REQUIRED <br /> FOR ALARM FINAL. <br /> EVERETT FIRE PANEL REPLACEMENT <br /> Subject To Field Inspection <br /> 6y The Fire Marshal <br /> W2640474 <br /> BOEING EVERETT FACILITY ►® <br /> 3003 WEST <br /> EVERETT, WASHINGTON 98203 <br /> CODE SUMMARY <br /> LAND USE CODE M-2 HEAVY INDUSTRIAL <br /> BUILDING CODE INTERNATIONAL BUILDING CODE <br /> OCCUPANCY GROUP F-1 (FACTORY)/ S-1 (STORAGE)/B (OFFICE) <br /> NON-SEPARATED <br /> CONSTRUCTION TYPE II-B (FULLY SPRINKLERED) <br /> BUILDING HEIGHT 50' +/- <br /> STORIES ONE PLUS MEZZANINE <br /> OCCUPANCY GROUP FLOOR AREA OCCUPANT LOAD <br /> PROJECT FIRST FLOOR S-1 165,000 SIF 5,000 SF 650 <br /> 30 <br /> LOCATION TOTAL FIRST FLOOR AREA 1'80,000 SF <br /> i EVERT SOUTH MEZZANINE B/(OFFICE) 11,250 SF 113 <br /> EAST MEZZANINE (UNOCCUPIED) 9,000 SF <br /> NORTH MEZZANINE B/ (OFFICE) 10,305 SF 103 <br /> * <br /> EXISTING MAJOR A/ ASSEMBLY 727 SF 49 <br /> BOEING FACIunsEs A/ ASSEMBLY 218 SF 15 <br /> ��� b IIIIIIII TOTAL MEZZANINE AREA 31,500 SF 280 <br /> ELLEWE J I ACCESSIBILITY REQUIREMENT WAC 51-40 <br /> FIRE PROTECTION FULLY AUTOMATIC SPRINKLER SYSTEM THROUGHOUT <br /> TRENTON ��,, z INTERIOR WALLS STEEL STUDS <br /> VIII STRUCTURAL FRAME STRUCTURAL STEEL <br /> ROOF STEEL DECK WITH SINGLE PLY MEMBRANE SYSTEM <br /> WENT o 40-56 FLOOR CONCRETE <br /> II. <br /> SCOPE OF WORK:UBURN <br /> �. o <br /> THE SCOPE OF THIS PROJECT IS TO UPGRADE THE BUILDING FIRE ALARM SYSTEM. <br /> ff i 40-83 ��Il <br /> 0 MI Es O _Eli % _ Win` I IIS R o 0_91,; THE WORK TO BE PERFORMED INCLUDES, BUT IS NOT LIMITED TO THE FOLLOWING: <br /> i< <br /> TACOMA 1 1. REMOVE 40-54 BUILDING ADT PANEL AND ASSOCIATED EQUIPMENT AS NOTED ON PLANS. <br /> ER �o��� _� SP w-a1 2. REMOVE EXCESS PRESSURE PUMP EQUIPMENT FROM ALL 40-54 FIRE SPRINKLER RISERS <br /> g 40-31 40-32 40-33 4D-34 AS NOTED ON DRAWINGS. PROVIDE WATERFLOW PRESSURE SWITCH WITH DELAY AND <br /> - <br /> Egg 1 5 40-35 40-36 ISOLATION TAMPER-AT EACH OF THESE LOCATIONS. <br /> rTTII 3. REMOVE CORRIDOR DOOR SMOKE/HEAT DETECTION THROUGHOUT 40-54 AS NOTED ON <br /> PROJECT X111 T� 4o-s3 DRAWINGS. <br /> r BUILDING 1Ji �� 1 4. REMOVE ALL VESDA EQUIPMENT IN BUILDING. <br /> - II PROJECT 5. REMOVE SIX (6) HONEYWELL DELTANET SMOKE/HEAT DETECTION PANELS. <br /> MISH 6 g�iLD NCG FACpFIRE ALARM FIELD DEVICES AND EQUIPMENT TO THE KIDDE ARIES NETLINK <br /> R/�eR SITE <br /> m 7. PROVIDE WATERFLOW PRESSURE SWITCH WITH DELAY AND ISOLATION TAMPERS AS <br /> NOTED ON DRAWINGS. <br /> INE FIELD o 8. MODIFY AND PROVIDE SWITCHES IN EXISTING HONEYWELL FAN CONTROL/STATUS PANEL. <br /> - 9. SEAL ALL CORRIDOR DOOR PENETRATIONS BY WELDING DOORS SHUT. <br /> o 10. REMOVE ALL CEILING HEAT DETECTION EQUIPMENT THROUGHOUT BUILDING 40-54. <br /> —SNOHOMI CO - <br /> I OWNER: BOEING COMMERCIAL AIRPLANE GROUP <br /> 3003 WEST CASINO ROAD <br /> EVERETT, WASHINGTON 98203 <br /> PROJECT MANAGER: MATT KENT <br /> TEL: 425.299.4719 <br /> ^I nI ELECTRICAL: ALEXANDER COW FIRE EQUIPMENT CO. <br /> VICINITY MAIn _LOCAL :iON MAP _SITE PLAN \I 1436 NW 53RD STREET <br /> SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S. V <br /> SEATTLE, WASHINGTON 98101 <br /> TEL 206.632.2810 <br /> I CONTACT: KEVIN MULLEN <br /> EMAIL: KMULLEN®GOWFIRE.COM <br /> i <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATEACCEPTABILITY D. SUBm'LE HEET <br /> CURRENT REVISION SYMBOL DATE <br /> THIS DESIGN AND CREN 07.25.07 COVER S10.04.19 <br /> - RECORD DRAWING J1567957 HGI 05.16.08 SPECIFICATION IS APPROVED D.BALCH 07.25.07 SHEET <br /> A EVERETT FIRE PANEL REPLACEMENT W2640474 SAZAN/ZO 05.29.19L ® APPROVED BY DEPT. DATE D. INE 07.25.07 TITLE FERE PANEL REPLACEMENT O <br /> CHECKED Gv <br /> B SHOP DRAWINGS AGOW/HG 10.04.19 — R. GWINN 07.25.07 <br /> ?ETE LINHEN BUILDING 40-054 567957 <br /> APPROVED JOB N0. COMP N0. <br /> B. HODGE 07.25-.07 <br /> R.GWINN 07.25.07 ELECTRICAL MASTER EVERETT, WA.' 40-054-00 <br />