Laserfiche WebLink
1 6 6 2 23 26 3 <br /> LEGEND <br /> SEE SHEET ETA FOR SYMBOLS AND ABBREVIATIONS <br /> 1-1/4"C, 6#14 <br /> B BUILDING FACP 1> 1"C, 16/6C <br /> MAN PULL @ EVT-FA-40-54 <br /> 0 0 <br /> A 1-1 002 /:SMK ® FRCP 1-1:001 <br /> FATC ACP g A <br /> lLJ <br /> GUTTER— - IV 4 <br /> E2V54-1A1/2a x VS x <br /> In <br /> 1-1/4"C, 34 14 UV54-6H WF LI:007 <br /> 2 AN CONTRO x --UV54-6H TAMPER U:008 x <br /> PANEL 1_1/4"c, s#14, #14 s IJ 1 4"C, 6#14, GENERAL NOTES <br /> 3/4", 14#14 -1-1/4"C, 20#14 INTO #14 <br /> INTO SLAB SLAB TO GUTTER LON <br /> D Q <br /> SOUTH SIDE OF BLDG <br /> 6 <br /> x - <br /> B <br /> 3/4"C, 6#1 777 EBU PRE-ASSEMBLY x 747-767 EBU PCA A <br /> 13A2 FllA2 _ B REFERENCE DRAWINGS <br /> a EE> E508 BUILDING FIRE ALARM RISER DIAGRAM <br /> 3/4"C, #14© x x w_ E508-8 FAN CONTROL PANEL DETAILS <br /> 1/2"C, 2#16 <br /> rn <br /> w <br /> w <br /> x N <br /> Z <br /> LJ O <br /> SV54-10 us B x CONSTRUCTION NOTES <br /> TAMPER FT7_ CONNECT EXISTING DEVICE TO NEW BUILDING FIRE <br /> 1 o ALARM CONTROLPANEL. UTILIZE EXISTING <br /> INFRASTRUCTURE. PROVIDE ADDITIONAL CONDUIT AND <br /> SV54-10 WF ISO TAMPER 777 EBU o A' CONDUCTORS AS REQUIRED. <br /> 1-1:009 SV54-10 WF PRESSURE L1:010 w <br /> L1:011 11 B1 x x I PROVIDE MONITORING DEVICE. INSTALL ON EXISTING <br /> SPRINKLER RISER. CONNECT TO NEW BUILDING FIRE <br /> = ALARM PANEL UTILIZE EXISTING INFRASTRUCTURE. <br /> x x PROVIDE ADDITIONAL CONDUIT AND CONDUCTORS AS <br /> REQUIRED. SEE DETAIL 1/E5D8-1 FOR INSTALLATION <br /> NOTES. <br /> x x <br /> >-PROVIDE REMOTE MONITOR MODULES FOR FIELD <br /> DEVICES. UTILIZE J-BOX FOR CONNECTIONS BETWEEN <br /> x x FIELD DEVICES AND NEW BUILDING FIRE ALARM <br /> CONTROL PANEL. <br /> 14 11\ x '15 B MODIFY FAN CONTROL PANEL TO REMOVE "AUTO" <br /> CONTROL FUNCTIONALITY. SEE SHEET E508-8 FOR <br /> X, x x X—x— —xxx" <br /> FAN CONTROL PANEL MODIFICATIONS. <br /> �REPURPOSE EXISTING TYCO PANEL AS A FIRE ALARM <br /> TERMINAL CABINET <br /> N ©REPLACE 22 AWG CONDUCTORS WITH #14 AWG FPL <br /> RATED CONDUCTORS, SIZES AND QUANTITY TO BE <br /> w DETERMINED. FIRE CONTRACTOR SHALL PROVIDE <br /> 777 EBU Ln <br /> ® _ ujRED-LINE MARK UP WITH INSTALLED SIZES AND <br /> 1181 ? QUANTITY. <br /> x <br /> 7. COORDINATE WITH FIRE SPRINKLER CONTRACTOR FOR <br /> I 111 11 1 PIPING MODIFICATIONS AS REQUIRED. <br /> MATCHLINE - FOR CONTINUATION EE SHEET 1A13 MATCHLINE SEE SHT. 1E263 B' <br /> 1 3 5 7 <br /> A <br /> iQ 1E261 1E262 <br /> PARTIAL PLAN VIEW B. <br /> SCALE: 1/8"=1'-0" 1E263 "1E264 1E265 <br /> C. <br /> 1E266 "1E267 1E268 <br /> - E <br /> 1F269 tE270 tE271 <br /> 5' F <br /> 1 A * DENOTES PLANS NOT <br /> *tE273 G INCLUDED IN THIS DRAWING <br /> KEY PLAN <br /> SCALE: NONE V <br /> 8' 4' 0 4' 8' 16' <br /> SCALE: 1/8"=1'-0" <br /> SYM REVISION BY APPROVED DATE SYM RLVISION BY APPROVED DATE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> ACCEPTABILITY ZG 05.29.19 FIRE ALARM SYSTEM PLAN-FIRST FLOOR C 10.04.19 <br /> A VSU INSTALL- FA ----- W5706595 MDK KER/VLV 12.20.18 THIS DESIGN AND/OR H ' <br /> ----- --- ----- -- --- ----- SPECIFICATION IS APPROVEDCK 0529.19 SHEET <br /> © EVERETT FIRE PANEL REPLACEMENT W2640474 SAZAN/ZO 05.29.19 ® m - TITLE EVERETT FIRE PANEL RF..PLACEMENT EE <br /> APPROVED BY DEPT, DATE CK __ 05.29.19 <br /> _ <br /> :. C SHOP DRAWINGS AGOW/HG 10.04.19 PlTELINANfN CK 05. BUILDING 40-054 _1 0 <br /> n 29.19 <br /> oe No. W2640474 COMP No. <br /> P ELECTRICAL MASTER COL. A-B.3 1-3 EVERETT, WA, DWG ND. 40-054-1E260 <br />