My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD 2019 BLDG 40-54 Plans 2023-12-28
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-54
>
Plans
>
3003 W CASINO RD 2019 BLDG 40-54 Plans 2023-12-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2023 2:00:59 PM
Creation date
12/28/2023 1:58:38 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-54
Permit
FA1910-004
Year
2019
Notes
EXPAND EXISTING FIRE ALARM TO COVER EXISTING SPRINKLER SYST
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
_ 1 1 .3 1 .6 2 2.3 2.6 3 SEE SHEEP E1A FOR SYMAOLS AND AAAREVIATIONS LEGEND <br /> MATCHLINE FOR CONTINUATION SEE SHEET 1A16 MATCHLINE SEE SHT. 1€266 <br /> I N <br /> 9 LEI IE 10 3 El 15 <br /> 71 W <br /> II II � <br /> II = <br /> AICORRIDOR <br /> II N <br /> w <br /> SE <br /> I IIw <br /> P VC414 I I 9.2:003 120 w <br /> II II z <br /> 11 3/4"C, 4#14 <br /> 1 Vs SV54J1 1-1/4"C, 20#14 INTO SLAB <br /> TAMPED AND BACK TO GUTTER o- <br /> GUTTER X X X X X —X——X°X X X ° X— X ° <br /> GENERAL NOTES <br /> 1 G.J <br /> I <br /> A i (2)1/2'0, #14 4 x <br /> SV54-14 L2:011 OPTIC STORAGE <br /> JI <br /> wF WF PRESSURE 1 1382 <br /> P o <br /> J 12 <br /> HI/LO AIR- L ' <br /> 4 x W <br /> I x <br /> I x x „N,I <br /> SV54-16R N <br /> Z REFERENCE DRAWINGS <br /> I 3/4"C, 16/20, 18 2C g <br /> 1/2C, 16/2C a <br /> I <br /> SV54-16C o� <br /> A CONSTRUCTION NOTES <br /> I <br /> I o <br /> 1� <br /> a L MOCK-UP ° ER CONNECT EXISTING DEVICE TO NEW BUILDING FIRE <br /> MECHANICAL I A E1ALARM CONTROL PANEL. UTILIZE EXISTING <br /> Lu I z INFRASTRUCTURE. PROVIDE ADDITIONAL CONDUIT AND <br /> CONDUCTORS AS REQUIRED. <br /> cn <br /> w I3/4"C, 6#14 <br /> N I PROVIDE MONITORING DEVICES. INSTALL ON EXISTING <br /> z I ° SPRINKLER RISER. CONNECT TO NEW BUILDING FIRE <br /> 0 I ALARM CONTROL PANEL. UTILIZE EXISTING <br /> R I INFRASTRUCTURE. PROVIDE ADDITIONAL CONDUIT AND <br /> z CONDUCTORS AS REQUIRED. SEE DETAIL 1/E508-1 <br /> MAINT. ROOM E. FOR INSTALLATION NOTES. <br /> I <br /> 118 A PROVIDE REMOTE MONITOR MODULES FOR FIELD <br /> j A ° DEVICES. UTILIZE J-BOX FOR CONNECTIONS BETWEEN <br /> FIELD DEVICES AND NEW BUILDING FIRE ALARM <br /> EMEz I _2:014 CONTROL PANEL. <br /> A OR SV54-11 WE ISO TAMPER <br /> toR <br /> SV54-11 WE PRESSURE <br /> GENERATOR L2:015 2:017 REPLACE 22 AWG CONDUCTORS WITH #14 AWG FPL <br /> I 119 x TOOL & WELD HOP 4-6E WE ISO TAMPER L2:018 RATED CONDUCTORS, SIZES AND QUANTITY TO BE <br /> 14E2 4-6E WE PRESSURE_ DETERMINED. FIRE CONTRACTOR SHALL PROVIDE <br /> 1 RED-LINE MARK UP WITH INSTALLED SIZES AND <br /> I 1"C, 1 #14, <br /> `"I x VS 3/4"C, 6#14 '3>-1/2"C, SV54 1"C, 6#14 <br /> 44 <br /> w 1 WF D) # 5. COORDINATE WITH FIRE SPRINKLER CONTRACTOR FOR <br /> N PD ® WF PO INT TUNNEL . <br /> PIPING MODIFICATIONS AS REQUIRED. <br /> �I <br /> 3 <br /> 0 Uj�r�f#12, <br /> #3/4"C, 6#14 1/2' #14 3/4"C, 18/4C ®1q2"C, #14 #14 <br /> TAMPER4 1 A <br /> SEC412 SEC411 <br /> L2:013- PIV PIV SEC410 <br /> VS VS PIV <br /> SV54-11 <br /> 1 -- .TAMPER L2:016 <br /> -- -------------------------------------------------------- ------------------------ a <br /> SV54-16G PIV SV54-16R PIV <br /> (OUT OF SERVICE) (OUT OF SERVICE) 1 3 5 7 <br /> 1_1/2"C, 16#1 -1-1/4"C, 12#14 <br /> PARTIAL PLAN VIEW � ,8260 18261 ,8262 A <br /> SCALE: 1/8"=1'-0" <br /> B. <br /> 1E263 "1E264 1E265 <br /> - C. <br /> 1E266 •tE267 1E266 <br /> �, E <br /> 18269 1€270 tE271 <br /> *DENOTES PLANS NOT F <br /> •,€273 INCLUDED IN THIS <br /> DRAWING SET <br /> ® KEY PLAN 0 <br /> SCALE: NONE <br /> G0O 8 4 0 4 8 16 <br /> SCALE: 1/8"=1'-0" <br /> SYM REVISION AY APPROVED DATE SYM REVISION AY APPROVED DATEACCEPTAAILITY DRAWN DATE 05.29.19 SUATITLE CURRENT REVISION SYMAOL B DATE <br /> A EVERETT FIRE PANEL REPLACEMENT W2640474 SAZAN/ZO 05.29.19 ZO <br /> THIS DESIGN AND/OR FIRE ALARM SYSTEM PLAN-FIRST FLOOR B 10.04.19 <br /> SPECIFICATION IS APPROVED CK 05.29.19 SHEET <br /> B SHOP DRAWINGS Acow/NG 10.04.19 ® m APPROVED AY DEPT. DATE CK 05.29.19 "TLE EVERETT FIRE PANEL REPLACEMENT 1 €269 <br /> BOE//Vl� CHECKED <br /> PETE LINdNEN CK 05.29.19 BUILDING 40-054 <br /> xee.a..o.x..a..irsrx JOA NO W2640474 COMP N0. <br /> ELECTRICAL MASTER COL. E-F/1-3 EVERETT, WA. DWG NO. 40-054-1E269 <br />