3003 W CASINO RD 2019 BLDG 40-54 Plans 2023-12-28
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-54
>
Plans
>
3003 W CASINO RD 2019 BLDG 40-54 Plans 2023-12-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2023 2:00:59 PM
Creation date
12/28/2023 1:58:38 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-54
Permit
FA1910-004
Year
2019
Notes
EXPAND EXISTING FIRE ALARM TO COVER EXISTING SPRINKLER SYST
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PROVIDE SMOKE DETECTORS IN <br />ELEVATOR PIT FOR ELEVATOR RECALL. <br />CONNECT TO FIRE ALARM PANEL — <br />30 <br />0 <br />1ST FLOOR <br />PROVIDE A 135 DEG HEAT DETECTOR LOCATED <br />WITHIN 24" OF EACH SPRINKLER HEAD IDENTIFIED <br />WITH A NAMEPLATE THAT READS: "ELEVATOR LIGHT SWITCH LOCATED ADJACENT TO ACCESS <br />CONTROL ONLY - DO NOT TEST" H S DOOR <br />PROVIDE LIGHT FIXTURES IN ELEVATOR PIT. WALL ELEVATOR PIT 3/4" RGS 2V54-2C6.6/26a <br />BRACKET MOUNTED WITH GUARDS. SPECTRUM OR 26 26 <br />EQUIVALENT. 28 ° GFCI 26 <br />GFCI <br />PROVIDE GFCI DUPLEX RECEPTACLE IN PIT <br />3 4" RGS 2V54-2C6.6/28b WITH CIRCUIT SUPPLYING BOTH PIT LIGHT AND <br />/ / RECEPTACLE FOR SUMP PUMP. RECEPTACLE. <br />PROVIDE A SINGLE RECEPTACLE FOR <br />AN ELEVATOR PIT SUMP PUMP WITH <br />A SEPARATE 20A 120V CIRCUIT. <br />ELEVATION — ELEVATOR HOISTWAY tl 2 <br />SCALE: N.T.S. 1 E65 E506 <br />SYM <br />I REVISION <br />BY APPROVED <br />DATE SYM REVISION BY APPROVED DATE <br />- <br />LEGEND <br />J1567957 HGI <br />05.16.08 <br />A <br />40-054 BUILDING MODIFICATIONS <br />10153855 CASNE CEC <br />SEE SHEET EIA FOR SYMBOLS AND ABBREVIATIONS <br />PROVIDE 135 DEG. HEAT DETECTOR WITHIN <br />RECORD DRAWING <br />10153855 OUR GROUP RJV <br />BUSSMANN POWER <br />MODULE SWITCH <br />B <br />EVERETT FIRE PANEL REPLACEMENT <br />18" OF EACH SPRINKLER HEAD. HEAT <br />05.29.19 <br />C <br />SHOP DRAWINGS <br />AGOW/HG <br />10.04.19 <br />DETECTORS PROVIDE AUXILIARY FUNCTION OF <br />ELEVATOR HYDRAULIC <br />2a,4b,6c <br />R P <br />PHENOLIC <br />30c <br />THE ELEVATOR EQUIPMENT AND SHALL BE <br />POWER UNIT <br />3b <br />ELEVATOR CONTROLLER <br />NAMEPLATE <br />7a,9b <br />IDENTIFIED WITH A NAMEPLATE THAT READS <br />(TYPICAL) <br />"ELEVATOR CONTROL ONLY - DO NOT TEST" <br />AUXILIARY CONTACT TO SIGNAL ELEVATOR <br />XE2V54-1MD6.6/3b <br />ELEVATOR <br />100A, 3P 70A <br />TO ELEVATOR <br />RECALL PROVIDE 1/2"C WITH (3)#1.4 AWG <br />3/4"C, 2#12 & 1#12 GND <br />POWER <br />CONTROLLER <br />CONDUCTORS TO ELEVATOR CONTROLLER <br />PROVIDE CONNECTION FROM BUSSMANN <br />SOURCE <br />(FURNISHED <br />- <br />POWER MODULE TO FIRE ALARM PANEL W/8 <br />BY OTHERS) <br />SMOKE DETECTOR IN ELEVATOR <br />#14 IN 3/4"C. <br />MACHINE ROOM FOR ELEVATOR RECALL. <br />CONNECT TO FIRE ALARM PANEL <br />PROVIDE 1" CONDUIT W/PULL STRING FROM <br />SHUNT TRIP WITH MECH. <br />FIRE ALARM PANEL TO ADT PANEL ON 2ND <br />INTERLOCKED AUX. <br />3/4"C-2#10 & 1#12 GND 2V54-2C6.6/25a <br />FLOOR AT COLUMN LINE A-10. <br />CLEARING CONTACT <br />ELEVATOR CAR HVAC ACU -1 DISCONNECTING <br />PROVIDE CONNECTION FROM ELEVATOR <br />GENERAL NOTES <br />MEANS. PROVIDE 20A 1P LOCKABLE ENCLOSED <br />E L EV CONTROLLER TO FIRE ALARM PANEL W/8 #14 <br />CIRCUIT BREAKER. PROVIDE ENGRAVED LABEL <br />F IN 3/4"C. <br />1. ELEVATOR SHUNT -TRIP CONTROL SYSTEM SHALL BE <br />PROVIDE DEDICATED 20A 120V CIRCUIT AND S <br />H C 6 FIRE ALARM PANEL <br />INSTALLED AND TESTED PER NFPA 72. <br />LOCKABLE 20A 1P ENCLOSED CIRCUIT <br />BREAKER FOR ELEVATOR CAR LIGHT SOURCE <br />+48 <br />PROVIDE ENGRAVED LABEL <br />120V <br />EN <br />LEVATOR CONTROLLER <br />(FURNISHED OTHERS) <br />KB_ --- I <br />"SHUNT TRIP READY" <br />3/4"C 3#12 & 1#12 GND <br />ELEVATOR CAR TELEPHONE J -BOX PROVIDE <br />G <br />XE2V54-iMD6.6/7a,9b <br />3/4"C TO CABLE TRAY ABOVE CEILING <br />PILOT LIGHT <br />3/4"C-2#10 & 1#12 GND <br />2V54-2C6.6/31a <br />3/4"C-2#10 & 1#12 GND 2V54-2C6.6/29c <br />R P <br />HEAT DETECTOR <br />ELEVATOR SHUNT TRIP CONTROL PANEL <br />PROVIDE CONNECTION FROM POWER <br />BUSSMANN MODULE TO FIRE ALARM PANELFIRE <br />Dm <br />CONTACTS IN <br />PARALLEL <br />BUSSMANN POWER MODULE SWITCH (MODEL <br />ALARM <br />PS) WITH CONTROL POWER TRANSFORMER. <br />PROVIDE 3#14 IN 3/4"C. <br />INTERFACE <br />GREEN PILOT LIGHT. KEY OPERATED TEST <br />ELEVATOR POWER SOURCE <br />K RELAY <br />REFERENCE DRAWINGS <br />SWITCH. AUXILIARY CONTACTS AND FIRE ALARM <br />1 1/2"C, 3#2 & 1#8 GND <br />KEY OPERATED <br />INTERFACE RELAY. SWITCH RATING AND FUSE <br />4V54-2MD6.6/2a,4b,6c <br />R p <br />TEST SWITCH <br />40-054-1E15 <br />SIZE AS INDICATED ON CONTROL DIAGRAM <br />40-054-1E65 <br />40-054-1E115 <br />R1 CLEARING SHUNT ELEVATOR <br />FLOOR PLAN — <br />ELEVATOR E UIPMENT ROOM z <br />CONTACT TRIP —CONTROLLER <br />SCALE: N.T.S. <br />1E115 E506 <br />AUXILIARY AUXILIARY <br />CONTACTS <br />jR2A R3ACONTACTS <br />(ELEVATOR (FUTURE <br />RECALL R38 REMOTE <br />LIGHT SWITCH AT HOISTWAY ACCESS POINT (TYP) <br />30� <br />SIGNAL) �� MONITORING) <br />SMOKE DETECTORS IN ELEVATOR MACHINE <br />3/4" RGS 2V54-2C6.6/30c <br />ROOM AND IN ELEVATOR LOBBIES WITHIN 21 <br />FEET OF CENTERLINE OF ELEVATOR DOOR <br />PROVIDE FIVE (5) LIGHT FIXTURES IN HOISTWAY. <br />FOR ELEVATOR RECALL CONNECT TO FIRE <br />ALARM PANEL (TYPICAL). <br />LOCATE ON 1ST AND 2ND FLOOR ON OPPOSITE <br />S <br />ELEVATOR <br />SHUNT—TRIP CONTROL DIAGRAM 3 <br />WALLS AND ON CEILING OF HOISTWAY. PROVIDE <br />SCALE: N.T.S. <br />1E65 E506 <br />SWITCHES TO CONTROL FIXTURES AT EACH HOIST <br />MEZZANINE <br />CONSTRUCTION 'NOTES <br />WAY ACCESS POINT. FIXTURES SHALL BE <br />METALUX VT2 SERIES OR EQUIVALENT. <br />30 130 <br />PROVIDE SMOKE DETECTORS IN <br />ELEVATOR PIT FOR ELEVATOR RECALL. <br />CONNECT TO FIRE ALARM PANEL — <br />30 <br />0 <br />1ST FLOOR <br />PROVIDE A 135 DEG HEAT DETECTOR LOCATED <br />WITHIN 24" OF EACH SPRINKLER HEAD IDENTIFIED <br />WITH A NAMEPLATE THAT READS: "ELEVATOR LIGHT SWITCH LOCATED ADJACENT TO ACCESS <br />CONTROL ONLY - DO NOT TEST" H S DOOR <br />PROVIDE LIGHT FIXTURES IN ELEVATOR PIT. WALL ELEVATOR PIT 3/4" RGS 2V54-2C6.6/26a <br />BRACKET MOUNTED WITH GUARDS. SPECTRUM OR 26 26 <br />EQUIVALENT. 28 ° GFCI 26 <br />GFCI <br />PROVIDE GFCI DUPLEX RECEPTACLE IN PIT <br />3 4" RGS 2V54-2C6.6/28b WITH CIRCUIT SUPPLYING BOTH PIT LIGHT AND <br />/ / RECEPTACLE FOR SUMP PUMP. RECEPTACLE. <br />PROVIDE A SINGLE RECEPTACLE FOR <br />AN ELEVATOR PIT SUMP PUMP WITH <br />A SEPARATE 20A 120V CIRCUIT. <br />ELEVATION — ELEVATOR HOISTWAY tl 2 <br />SCALE: N.T.S. 1 E65 E506 <br />SYM <br />I REVISION <br />BY APPROVED <br />DATE SYM REVISION BY APPROVED DATE <br />- <br />RECORD DRAWING <br />J1567957 HGI <br />05.16.08 <br />A <br />40-054 BUILDING MODIFICATIONS <br />10153855 CASNE CEC <br />06.04.10 <br />- <br />RECORD DRAWING <br />10153855 OUR GROUP RJV <br />04.07.11 <br />B <br />EVERETT FIRE PANEL REPLACEMENT <br />W2640474 SAZAN/ZO <br />05.29.19 <br />C <br />SHOP DRAWINGS <br />AGOW/HG <br />10.04.19 <br />o�--AffdffAlIFAfW"° <br />EQUIPMENT <br />PANEL <br />CIRCUIT <br />ELEVATOR PIT RECEPTACLE <br />2V54 -2C6.6 <br />26a <br />ELEVATOR PIT SUMP RECEPTACLE <br />2V54 -2C6.6 <br />28b <br />ELEVATOR PIT LIGHT <br />2V54 -2C6.6 <br />26a <br />ELEVATOR EQUIPMENT ROOM LIGHT <br />2V54 -2C6.6 <br />27b <br />ELEVATOR EQUIPMENT ROOM OUTLET <br />2V54 -2C6.6 <br />29c <br />ACU -1 (ELEV EQUIP ROOM (EER) <br />2V54 -2C6.6 <br />25c <br />ELEVATOR CAR LIGHT <br />2V54 -2C6.6 <br />31a <br />BUSSMAN POWER MODULE SWITCH <br />4V54-2MD6.6 <br />2a,4b,6c <br />ELEVATOR SHAFT LIGHTS <br />2V54 -2C6.6 <br />30c <br />ELEVATOR FIRE PANEL <br />X2V54-1MD6.6 <br />3b <br />ELEVATOR CONTROLLER <br />X2V54-1MD6.6 <br />7a,9b <br />208Y /120V CIRCUIT & PANEL SCHEDULE <br />SCALE: N.T.S. 1E115 & 1E6 <br />,5 E506 <br />FOR REFERENCE ONLY <br />DRAWN <br />ACCEPTABILITY C. CLEVER JLB 07.10.07 "'rrLE <br />THIS DESIGN AND/OR P. TSCHERNEGA oz2s.o7 - ELECTRICAL DETAILS <br />m SPECIFICATION 15 APPROVEDERMREErwLE <br />APPROVED BY DEPT. DATE R. HURST 07.25.07CHECKED <br />EVERETT FIRE PANEL REPLACEMENT <br />D. LEAVTT 07.25.07 BUILDING 40-054 <br />APPR <br />S. HODGE 07.25.07 <br />R. cwINN 07.25.07 ELECTRICAL MASTER <br />„ „CVIS M„VL G IAIL 10.04.19 <br />SHEIE <br />E506 <br />JOB NO. 567957 COMP N0. <br />EVERETT, WA, MG NO. 40-054-E506 <br />