My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2616 COLBY AVE FRYING LEMON FISH 2024-02-09
>
Address Records
>
COLBY AVE
>
2616
>
FRYING LEMON FISH
>
2616 COLBY AVE FRYING LEMON FISH 2024-02-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2024 1:30:36 PM
Creation date
12/29/2023 3:31:31 PM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
2616
Tenant Name
FRYING LEMON FISH
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
134
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 22 <br />Table 2.3.2 Frequently Used Load Duration <br />Factors, Co' <br />Load Duration Co Typical Design Loads <br />Permanent 0.9 Dead Load <br />Ten years 1.0 Occupancy Live Load <br />Two months 1.15 Snow Load <br />Seven days 1.25 Construction Load <br />Ten minutes 1.6 WindTarthquake Load <br />Impact'' 2.0 Impact Load <br />1 Load duration factors shall not apply to reference modulus of dastict- <br />ty. L. reference modulus of elasticity for beam and column stability. <br />E_, nor to reterence n comprrssn perpendicular to grain design values, <br />L based on a deformation limit. <br />2 Load duration factors greater than 1 6 shall not apply to structural <br />members pressure -treated with water -home preservauves tsee Refer- <br />ence 301, or m fire retardant cltercats. The impact load duration factor <br />shall not apply to connections <br />2.3.3 Temperature Factor, Ct <br />Reference design values shall be multiplied by the <br />temperature factors, C,, in Table 2.3.3 for structural <br />members that will experience sustained exposure to ele- <br />vated temperatures up to 150'F (see Appendix C). <br />P19- t 21772 ; Z , �T. � rT E_t'T_171i <br />The effects of fire retardant chemical treatment on <br />strength shall be accounted for in the design. Adjusted <br />design values, including adjusted connection design <br />values, for lumber and structural glued laminated timber <br />pressure -treated with fire retardant chemicals shall be <br />obtained from the company providing the treatment and <br />redrying service_ Load duration factors greater than 1.6 <br />shall not apply to structural members pressure -treated <br />with fire retardant chemicals (see Table 2.3.2). <br />Table 2.3.3 Temperature Factor, Ct <br />2.3.5 Format Conversion Factor, Ks (LRFD <br />Only) <br />For LRFD, reference design values shall be multi- <br />plied by the format conversion factor, Kf, specified in <br />Table 2.3.5. The format conversion factor, Kr, shall not <br />apply for designs in accordance with ASD methods <br />specified herein. tp <br />2AL6 Resistance Factor, to (LRFD Only) <br />For LRFD, reference design values shall be multi- <br />plied by the resistance factor, 4o, specified in Table 2.3.6. <br />The resistance factor, 40, shall not apply for designs in <br />accordance with ASD methods specified herein. <br />2AL7 Time Effect Factor, A. (LRFD Onyx) <br />For LRFD, reference design values shall be multi- <br />plied by the time effect factor, A, specified in Appendix <br />N.3.3- The time effect factor, k, shall not apply for de- <br />signs in accordance with ASD methods specified herein_ <br />Reference Design In -Service C, <br />Values Moisture <br />Conditions, TSIOO*F 1000F<T5125*F 1250F<f1I5eF <br />F,, E. E_ Wet or Dry 1.0 0.9 0.9 <br />Dry 1.0 0.8 0.7 <br />Fb, F,, Fes, and F.1 Wet 1.0 0.7 0.5 <br />I Wet and dry service conditions for sawn lumber, structural glued laminated umber, prefahncated wood 1 jot_sts, stnctml <br />composite lumber, wood structural panels and cross-lammated timber are specified in 4.1.4, 5.1.4, 7.1.4, 9.1.4. 9.3.3. and <br />10. 1,5 respectively <br />
The URL can be used to link to this page
Your browser does not support the video tag.