DESIGN SPECIFICATION ROOF DESCRIPTION <br /> RISK CATEGORY: II ROOF ROOF TILT AZIMUTH RAFTER RAFTER ROOF MATERIAL <br /> SIZE SPACING <br /> CONSTRUCTION: SFD <br /> #1 13° 267° 2"X4" I 24"o.c. COMP. SHINGLE <br /> ZONING: RESIDENTIAL ARRAY AREA & ROOF AREA CALC'S <br /> SNOW LOAD (ASCE 7-16): 25 PSF <br /> (E) UTILITY METER ARRAY ROOF ROOF <br /> AREA <br /> EXPOSURE CATEGORY: C (N) NON-FUSED AC DISCONNECT ROOF MODULES AREA (Sq AREA COVERED BY <br /> (N) IQ COMBINER BOX (Sq. Ft.) ARRAY(%) <br /> WIND SPEED (ASCE 7-16): 110 MPH #1 20 422.40 719.00 59 <br /> MODULE TYPE, DIMENSIONS&WEIGHT C AC UM LEGEND <br /> NUMBER OF MODULES: 20 MODULES Map (N) MAIN SERVICE PANEL H (N)JUNCTION BOX <br /> HANWHA Q CELL Q.PEAK DM (E)UTILITY METER SYSTEM INFO. <br /> MODULE TYPE: DUO BLK ML-G10+ (400W) MS (N)MAIN SERVICE PANEL(MSP) (20)HANWHA Q CELL Q.PEAK DUO BLK <br /> ACM L-G 10+(400W) <br /> MODULE WEIGHT: 48.5 LBS (N)NON-FUSED AC DISCONNECT <br /> (20)ENPHASE IQ7PLU5-72-2-US(240V) <br /> ® (N)IQ COMBINER BOX DC SYSTEM SIZE 8.00 KWDC <br /> MODULE DIMENSIONS: 74.0" x 41.1" = 21.12SF 00 -VENT,ATTIC FAN(ROOF OBSTRUCTION) AC SYSTEM SIZE 5.90 KWAC <br /> UNIT WEIGHT OF AREA: 2.30 PSF ❑ -ROOFATTACHMENT REVISIONS <br /> DESCRIPTION DATE REV <br /> MODULE, ARRAY WEIGHT (LOAD CALC'S) <br /> Number of Modules 20 <br /> Module Weight 48.50 LBS Signature with Seal <br /> Total Module (Array)Weight 970.00 LBS 36" FIRE SETBACK (N)JUNCTION BOX f <br /> = W <br /> Number of Attachment point 41 Ql <br /> Mounting System Weight 0.50 LBS Fn () <br /> (Per Module) �i <br /> Total Mounting System Weight 20.50 LBS ❑ O <br /> Q <br /> No. of Racking 11.00 PROJECT NAME&ADDRESS� z 70 <br /> Racking system Weight 6.89 LBS z m <br /> Total Racking system Weight 75.79 LBS (J) 0 Q z O <br /> Total System Weight —0 Rl 000 <br /> 0 <br /> (Total Module Weight+Total Mounting System Weight+Total 1066.29 LBS 70n ❑ z (n w CD _M <br /> Racking System Weight) ROOF ^ fV 1 1 I /) 00 C) <br /> Weight at Each Attachment Point 23.66 LBS C)FTI UQ) W °' \rn1 W U J M <br /> (Array Weight/Number of Attachment Point) F#1 —4 o <br /> Fn - ❑ z � >Q � <br /> Module Area (74.0"x41.1") 21.12 SgFt z TILT-13° J LU > (D <br /> AZIM.-267° m Q o O <br /> Total Array Area 422.40 SgFt rn = m Z ~ o <br /> Distributed Load 2.52 Per SgFt 00 ❑ w �W/ Y � . . <br /> (Total System Weight/Total Array Area) > Z LL 0 W <br /> Total Roof Area 2047.00 SgFt ❑ z W d <br /> Total Percentage or Roof Covered 20.64% J Q <br /> Total Array Area/Total Roof Area) 00 <br /> ROOF#1 <br /> (20) HANWHA Q CELL Q.PEAK DUO BLK ML-G10+ (400W) MODULES 41 .1" <br /> : <br /> (20) ENPHASE IQ7PLUS-72-2-US(240V) MICROINVERTERS ❑ DATE03/31/2022 <br /> SHEET NAME <br /> (N) UNIRAC SOLARMOUNT LIGHT RAIL <br /> ROOF PLAN & <br /> MODULES <br /> (41) RT MINI II @ 48"D.C. o <br /> W 6" FIRE SETBACK SHEET SIZE <br /> ti <br /> ANSI B <br /> 12'-0" 11" X 17" <br /> 2'-311 1'-7" HANWHA Q CELL SHEET NUMBER <br /> 1 ROOF PLAN & MODULES Q.PEAK DUO BLK <br /> PV-2 SCALE: 1/8"= 1'-0" ML-G10+ (400W) PV-2 <br /> MODULES <br />