607 KINGS PL 2024-01-26
>
Address Records
>
KINGS PL
>
607
>
607 KINGS PL 2024-01-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/10/2024 11:52:29 AM
Creation date
1/5/2024 11:07:28 AM
Metadata
Fields
Template:
Address Document
Street Name
KINGS PL
Street Number
607
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SOLAR MODULE SPECIFICATIONS Voltage rise in Q Cable from the Microinverters to the Junction Box <br /> HANWHA Q CELL Q.PEAK DUO For branch circuit #1 of 9 IQ 7+ Micros, the voltage rise on the 240 VAC Q Cable is 0.38% <br /> MANUFACTURER/ MODEL BLK ML-G10+ (400W) For branch circuit #2 of 11 IQ 7+ Micros, the voltage rise on the 240 VAC Q Cable is 0.56% <br /> VMP 37.13 V <br /> IMP 10.77A Voltage rise from the Junction Box to the IQ Combiner box <br /> voc 45.30 V VRise = (amps/inverter x number of inverters) x (resistance in 0/ft) x (2-way wire length in ft) <br /> ISC 11.14 A = (1 .21 amp x 11 ) x (0.00205 0/ft) x (36 ft x 2) <br /> TEMP. COEFF. VOC -0.27 %/K = 13.31 amps x 0.00205 Q/ft x 72 ft <br /> PTC RATING 376.55W = 1 .96 volts SYSTEMINFO. <br /> (20)HANWHA Q CELL Q.PEAK DUO BLK <br /> MODULE DIMENSION 74.0" (L) x 41.1" (W) %VRise = 1 .96 volts - 240 volts = 0.82% ML-G10+(40OW) <br /> (20)ENPHASE IQ7PLUS-72-2-US(240V) <br /> PANEL WATTAGE 40OW The voltage rise from the Junction Box to the IQ Combiner Box is 0.82% DC SYSTEM SIZE:8.00KWDC <br /> AC SYSTEM SIZE:5.90 KWAC <br /> INVERTER SPECIFICATIONS Voltage rise from the IQ Combiner box to the AC Disconnect REVISIONS <br /> MANUFACTURER/ MODEL EN PHASE IQ7PLUS-72-2-US(240V) DESCRIPTION DATE REV <br /> MAX DC SHORT CIRCUIT VRise = (amps/inverter x number of inverters) x (resistance in /ft.) x (2-way wire length in ft.) <br /> CURRENT 15 A = (1 .21 amp x 20) x (0.000491 0/ft) x (5 ft. x 2) <br /> CONTINUOUS OUTPUT = 24.20 amps x 0.000491 Q/ft x 1 Oft. Signature with Seal <br /> CURRENT 1.21A (240V) = 0.12 volts <br /> AMBIENT TEMPERATURE SPECS %VRise = 0.12 volts _ 240 volts = 0.05% <br /> RECORD LOW TEMP -5°C The voltage rise from the IQ Combiner Box to the AC Disconnect is 0.05% <br /> AMBIENT TEMP (HIGH TEMP 2%) 26°C Voltage rise from the AC Disconnect to the Main Service Panel <br /> CONDUIT HEIGHT 7/811 VRise = (amps/inverter x number of inverters) x (resistance in 0/ft) x (2-way wire length in ft) <br /> ROOF TOP TEMP 9O�C PROJECT NAME&ADDRESS <br /> _ (1 .21 amp x 20) x (0.000491 0/ft) x (5 ft x 2) <br /> CONDUCTOR TEMPERATURE RATE 48°c = 24.20 amps x 0.000491 0/ft x 10 ft <br /> MODULE TEMPERATURE COEFFICIENT OF VOC -0.27 %/K = 0.12 VOItS 0 coco <br /> o <br /> NUMBER OF CURRENT %VRise = 0.12 volts - 240 volts = 0.05% w N <br /> 00 <br /> PERCENT OF VALUES CARRYING CONDUCTORS The voltage rise from the AC Disconnect to the Main Service Panel is 0.05% W U g �' o <br /> IN EMT J IZ a <br /> 0.70 7-9 Total system voltage rise for all wire sections = Z o <br /> 0.56 % + 0.82% + 0.05% + 0.05% = 1 .48% Q w Y W o <br /> 0.50 10-20 z C) > 4t <br /> z W Z0- <br /> <Q <br /> DATE:03/31/2022 <br /> SHEET NAME <br /> SPECIFICATIONS <br /> & CALC. <br /> SHEET SIZE <br /> ANSI B <br /> 11" X 17" <br /> SHEET NUMBER <br /> PV-4A <br />
The URL can be used to link to this page
Your browser does not support the video tag.