My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2214 7TH ST 2016-06-01
>
Address Records
>
7TH ST
>
2214
>
2214 7TH ST 2016-06-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2016 8:34:07 AM
Creation date
6/1/2016 8:34:05 AM
Metadata
Fields
Template:
Address Document
Street Name
7TH ST
Street Number
2214
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OVER-THE-COUNTER ELECTRICAL PERMIT CHECKLIST FOR RESIDENTIAL SOLAR <br /> PHOTOVOLTAIC SYSTEMS <br /> Contractors can apply for an Over-The-Counter(OTC)permit where the PV system meets the requirements listed <br /> in this Checklist and use a template electrical diagram provided by the City or other approved diagram.All <br /> project plans and supporting documentation must be provided on site for the inspector. <br /> TO BE COMPLETED BY APPLICANT <br /> 0 Project Information <br /> Property Owner Name: Barbara Knorr <br /> Project Address: 2214 7th St. Parcel# <br /> City:Everett State:WA ZIP:98201 <br /> Day Phone: 206-527-9449 <br /> Contractor Name A&R SOLAR CORP <br /> Contractor License it RSOLAR*903JM <br /> Contractor Day Phone: 206-707-9937 <br /> PV system description Installing a 3.420kW Photovoltaic System on the roof. <br /> (include manufacturer (12) Itek Energy 285W <br /> and model#of PV (1) Solectria 3800TL <br /> modules and <br /> inverters): <br /> ©Determine if your project qualifies for an Over-the-Counter electrical permit <br /> Yes No N/A <br /> 1. PV modules, inverters, and combiner boxes are identified for use in PV systems. WI ❑ <br /> 2. The inverters are listed and labeled in accordance with UL 1741 and are listed for ✓ ❑ <br /> utility interaction. [IRC M2302.4] <br /> 3. The AC interconnection point is on the load side of service discornect. [NEC 690.64(B)] <br /> 7 <br /> 4. The system meets all current NEC, City and Washington Cities Electrical Code I� I ❑ <br /> requirements. <br /> 5. For Split-Buss modules the AC interconnection must be one of the six service ❑ 0 ❑� <br /> disconnects. <br /> 6. Maximum load added to the panelboard is based on the rating of the panelboards bus/main OCPD <br /> combination in accordance with NEC 705.12(D)(2)(3)(b), and is limited to(check combination that <br /> applies): <br /> 0225 amp bus/200 amp main OCPD-13,440 AC watts,maximum 70 amp inverter OCPD. <br /> AC watts,maximum 45 amp amp bus/225 amp main OCPD 8,640 inverter OCPD. <br /> 8200 amp bus/200 amp main OCPD- 7,860 AC watts,maximum 40 amp inverter OCPD. <br /> ❑150 amp bus/1S0 amp main OCPD- 5,760 AC watts,maximum 30 amp inverter OCPD. <br /> 0125 amp bus/125 amp main OCPD- 4,800 AC watts,maximum 25 amp inverter OCPD. <br /> 0125 amp bus/100 amp main OCPD- 9,600 AC waas,maximum 50 amp inverter OCPD. <br />
The URL can be used to link to this page
Your browser does not support the video tag.