i S SHUTLER <br /> III Ilk II CONSULTING <br /> __ ENGINEERS,INC. 12503 Bel-Red Road,Suite 100,Bellevue,WA 98005*(425)450-4075 <br /> August 11, 2022 <br /> John Llacuna <br /> SynThesis PLLC <br /> 12503 Bel-Red Road, Suite 100 <br /> Bellevue, WA 98005 <br /> Re: BP Everett 500 Building B Building Peiinit Review Letter <br /> 5900 36th Ave W, Bldg B <br /> Everett, WA 98203 <br /> Plan Check number: B2204-050 <br /> Dear John, <br /> We are in receipt of the Structural Engineering Review for BP Everett 500 Building B. The following <br /> clarifications are in response to the structural items in the review: <br /> 1. The lateral system is a combination of special reinforced concrete shear walls and special steel <br /> concentrically braced frames. This has been clarified in the general notes on sheet S-1.0. <br /> 2. The load cases used in design of the system are for normal loading of the braced bay. Case one is <br /> when the loading is balanced between tension and compression. Case two is how we internally <br /> determine if the loading delivered to the system will cause the brace to buckle. Case three is how <br /> we determine the maximum compression load applied to the column using overstrength, which we <br /> also design the connections for. Calculations on sheets L-22a and L-23a verify the maximum level <br /> of load transferable to the system by overturning analysis. <br /> 3. Braced frame beam has been revised to a size that meets highly ductile member requirements. <br /> 4. Sheet L-26 has been revised as redundancy is not necessary in design of collector element <br /> connections. <br /> 5. Protected zones have been added to the elevation on sheet S-3.1. <br /> 6. This loading is to represent maximum force that can be delivered to the system. On revised <br /> calculation package sheet L-32 we have performed an overturning analysis of the braced frame <br /> footing,resulting in the maximum load which can be accepted by the system. This load is compared <br /> to Cases II and III for the applied load, and the higher values are used for design. <br /> 7. Panel overturning has been checked on calculation sheets L-43 through L-46 of the revised <br /> structural calculation package. The required connection to stitch appropriate panels together are <br /> now shown on the panel elevations. <br /> 8. This requirement is specifically for pre-cast concrete construction,which in our opinion,site cast <br /> concrete tilt-up panels are not. I have included an article from Structure Magazine which discusses <br /> this topic for design. <br /> Please contact our office should you have any further questions or if you require additional information. <br /> Sincerely, <br /> Dmitri Vorobiev, P.E. Project Engineer <br />