Laserfiche WebLink
8. Whenever the building or structure, or any portion thereof,because of(i) dilapidation, <br /> deterioration or decay; (ii) faulty construction; (iii)the removal, movement or <br /> instability of any portion of the ground necessary for the purpose of supporting such <br /> building; (iv) the deterioration, decay or inadequacy of its foundation; of(v) any other <br /> cause, is likely to partially or completely collapse. <br /> 9. Whenever, for any reason, the building or structure, or any portion thereof, is <br /> manifestly unsafe for the purpose for which it is being used. <br /> 10. Whenever the exterior walls or other vertical structural members list, lean or buckle to <br /> such an extent that a plumb line passing through the center of gravity does not fall <br /> inside the middle one third of the base. <br /> 11. Whenever the building or structure, exclusive of the foundation, shows 33 percent or <br /> more damage or deterioration of its supporting member or members, or 50 percent <br /> damage or deterioration of its nonsupporting members, enclosing or outside walls or <br /> coverings. <br /> 12. Whenever the building or structure has been so damaged by fire, wind, earthquake or <br /> flood, or has become so dilapidated or deteriorated as to become (i) an attractive <br /> nuisance to children; (ii) a harbor for vagrants, criminals or immoral persons; or as to <br /> (iii) enable persons to resort thereto for the purpose of committing unlawful or <br /> immoral acts. <br /> 13. Whenever any building or structure has been constructed, exists or is maintained in <br /> violation of any specific requirement or prohibition applicable to such building or <br /> structure provided by the building regulations of this jurisdiction, as specified in the <br /> Building Code or Housing Code, or of any law or ordinance of this state or <br /> jurisdiction relating to the condition, location or structure of buildings. <br /> 14. Whenever any building or structure which, whether or not erected in accordance with <br /> all applicable laws and ordinances,has in any nonsupporting part, member or portion <br /> less than 50 percent, or in any supporting part, member or portion less than 66 percent <br /> of the (i) strength, (ii) fire-resisting qualities or characteristics, or(iii)weather- <br /> resisting qualities or characteristics required by law in the case of a newly constructed <br /> building of like area,height and occupancy in the same location. <br /> 15. Whenever a building or structure, used or intended to be used for dwelling purposes, <br /> because of inadequate maintenance, dilapidation, decay, damage, faulty construction <br /> or arrangement, inadequate light, air or sanitation facilities, or otherwise, is <br /> determined by the health officer to be unsanitary, unfit for human habitation or in <br /> such a condition that is likely to cause sickness or disease. <br /> 16. Whenever any building or structure,because of obsolescence, dilapidated condition, <br /> deterioration, damage, inadequate exits, lack of sufficient fire-resistive construction, <br /> faulty electric wiring, gas connections or heating apparatus, or other cause, is <br /> determined by the fire marshal to be a fire hazard. <br /> 17. Whenever any building or structure is in such a condition as to constitute a public <br /> nuisance known to the common law or in equity jurisprudence. <br /> 18. Whenever any portion of a building or structure remains on a site after the demolition <br /> or destruction of the building or structure or whenever any building or structure is <br /> abandoned for a period in excess of six months so as to constitute such building or <br /> portion thereof an attractive nuisance or hazard to the public. <br /> 5 <br />