My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-01 2024-03-01
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-01
>
3003 W CASINO RD BLDG 40-01 2024-03-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/1/2024 7:31:07 AM
Creation date
2/1/2024 3:27:52 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-01
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PLAN SYMBOLS <br /> GROUNDING POWER CONT LIGHTING SINGLE LINE SCHEMATIC ABBREVIATIONS GENERAL NOTES <br /> GROUND CABLE CONNECTION ® TELEPHONE/POWER POLE $ $J $4 TOGGLE SWITCHES - LINE VOLTAGE, BUS DUCT PRESSURE SWITCH - N.O. AF AMPS-FRAME 1. CONDUIT: 1/2" MINIMUM - TYPE AND SIZE IN <br /> T SINGLE POLE/ 3-WAY/ 4-WAY. NUMBER CB 800 AF800 AT WITH BREAKER �� CLOSES ON RISING PRESSURE AFF ABOVE FINISHED FLOOR ACCORDANCE WITH PLAN DRAWINGS AND THE <br /> TIME CLOCK OF SWITCHES UNDER COMMON PLATE AHC ABOVE HUNG CEILING SPECIFICATIONS. <br /> � GROUND ROD CONNECTION AS INDICATED AL ALUMINUM <br /> BUSDUCT PLUG-IN CIRCUIT BREAKER FLOAT OR LEVEL SWITCH - N.C. ATS AUTOMATIC TRANSFER SWITCH 2. CONDUCTORS SHOWN: #12 AWG, STRANDED COPPER, <br /> GROUND CABLE PIGTAIL $w 2$u, 3$w LOW-VOLTAGE LIGHTING CONTROL OPENS ON RISING LEVEL AT AMPS-TRIP INSULATION TYPE THHN/THWN, UNLESS OTHERWISE <br /> 6 SWITCHES. NUMBER OF SWITCHES UNDER 480V AWG AMERICAN WIRE GAUGE NOTED. <br /> —G— GROUND CABLE (UNDERGROUND) POWER RECEPTACLES COMMON PLATE AS INDICATED 1D10-1 PANLLBOARD FLOAT OR LEVEL SWITCH - N.O. CB CIRCUIT BREAKER 3. COLOR CODE CONDUCTORS: IDENTIFY CONDUCTORS <br /> a,b,c LOWER CASE LETTER INDICATES SWITCHING 600 A (RATINGS AS CLOSES ON RISING LEVEL CFCI CONTRACTOR FURNISHED WHICH DO NOT HAVE APPROPRIATELY COLORED <br /> —G— INSULATED GROUND BUS BAR DUPLEX 120V RECEPTACLE, HUBBELL CAT. GROUP M.L.O. NOTED) <br /> NO. 5262. PROVIDE LOW-VOLTAGE SWITCH CONTROL 3 PH, 3 W CONTRACTOR INSTALLED INSULATION WITH COLOR TAPE WHEREVER <br /> C.O. CO CONDUIT ONLY CONDUCTORS ARE ACCESSIBLE. IDENTIFY INSULATED <br /> WIRING AS 3/C #18 AWG IN 1/2" MIN. C FLOW SWITCH - N.C. GROUND CONDUCTORS PER NEC 250-57(b) EXCEPTION <br /> POWER FOURPLEX 120V RECEPTACLE, 2 HUBBELL FROM EACH LOW VOLTAGE SWITCH OPENS ON INCREASE IN FLOW CRU COMPUTER ROOM UNIT #1,b OR c (USING TAPE). COLOR CODE AS FOLLOWS: <br /> CAT. NO. 5262. TO THE LIGHTING CONTROL PANEL DED DEDICATED <br /> PANELBOARD, 208Y/12OV, 3 PHASE UNLESS OTHERWISE NOTED. 480Y/277V DP DISTRIBUTION PANEL BOARD 208Y/120 480Y/277 <br /> (E INDICATES SHUNT-TRIP) 1010-101 PANELBOARD FLOW SWITCH - N.O. EF EXHAUST FAN A 0 (LEFT BUS IN PNL) BLACK BROWN <br /> 39 DUPLEX 120V RECEPTACLE ON DROP CORD 2$m $. MOTION SENSOR SWITCH CONTROL 225A (RATINGS AS CLOSES ON INCREASE IN FLOW EMCS ENERGY MANAGEMENT CONTROL SYSTEM B 0 CENTER BUS IN PNL) RED ORANGE <br /> ® PANELBOARD, 480Y/277V, 3 PHASE DED IN ACCORDANCE WITH BOEING STANDARD. MAIN BKR NOTED) EMT ELECTRICAL METALLIC TUBING C 0 RIGHT BUS IN PNL) BLUE YELLOW <br /> O PANELBOARD, 400 HZ, 200Y/115V DEDICATED CIRCUIT. $m LUTRON NTHF-40 HI-LUME FLUORESCENT 30, 4W TEMPERATURE SWITCH - N.C. EPO EMERGENCY POWER OFF NEUTRAL WHITE GRAY <br /> DIMMING CONTROL AND BALLAST STSTEM. ES EPO SWITCH EQUIPMENT GROUND GREEN GREEN <br /> +� PANELBOARD, 28 VDC FOURPLEX 120V RECEPTACLE ON DROP OPENS ON RISING TEMP EWC ELECTRIC WATER COOLER ISOLATED GROUND GRN/YEL* GRN/YEL* <br /> BED $� INCANDESCENT DIMMER LUTRON FACP FIRE ALARM CONTROL PANEL *GREEN WITH YELLOW TRACER <br /> CORD IN ACCORDANCE WITH BOEING 208V OR 208Y/120V <br /> ® DC PANEL POWER SUPPLY, SIZE AS NOTED NTLV 600 SERIES TEMPERATURE SWITCH - N.O. FAR FIRE ALARM RELAY <br /> STANDARD. DEDICATED CIRCUIT. 1D10-2 PANELBOARD FATU FAN TERMINAL UNIT 4. LABEL EACH RECEPTACLE, JUNCTION/OUTLET BOX <br /> 225 A INCANDESCENT DIMMMER, HIGH WATTAGE (RATINGS AS CLOSES ON RISING TEMP FDP FIRE DETECTION PANEL <br /> AND SWITCH WITH CIRCUIT IDENTIFICATION AS <br /> eX EQUIPMENT IDENTIFICATION"X" DENOTES EQUIPMENT NUMBER COMMUNICATIONS $or 1000 AS NOTED. LUTRON MODEL NUMBERS: M. BKR. NOTED) FVNR FULL VOLTAGE, NON-REVERSING SCHEDULED ON SHEETS E1 B & ElC, USING TYPED <br /> "Y" DENOTES HP, KVA OR KW RATING 1 TELEPHONE OUTLET 1500 NT-1000 3 PH, 4 W ��r LIMIT SWITCH - N.C. OR GROUND FAULT INTERRUPTER LABEL. <br /> ® CIRCUIT BREAKER ENCLOSURE 2 NT-1500 COMBINATION STARTER ^�� GND G GROUND 5. INSTALL NEW OR REVISED PANEL SCHEDULES UPON <br /> 1 DUPLEX TELEPHONE OUTLET RESPECTIVELY LIMIT SWITCH - N.O. HP HORSEPOWER COMPLETION OF JOB. <br /> CONTROLLER OR MCC NO HIGH OUTPUT <br /> 3A 6. PANELS ARE TO BE IDENTIFIED BY LAMINATED <br /> E' CKT. BKR. ENCLOSURE WITH SHUNT-TRIP 1W WALL MOUNTED TELEPHONE OUTLET 7 CUBICLE NUMBER IMC INTERMEDIATE METAL CONDUIT PHENOLIC NAMEPLATES. <br /> DIAGRAM SYMBOLS RELAYS & COILS LOP LIGHTING CONTROL PANEL <br /> E' DISCONNECT SWITCH (FUSED OR UNFUSED) �- *=TYPE LED LIGHT EMITTING DIODE <br /> 30/20 SWITCH RATING/FUSE RATING © FLUSH MOUNTED SIGNAL BELL SINGLE LINE M=MOTOR STARTER My BKR. MN OEAKEROAVOLTAGE <br /> a MOTOR STARTER (COMBINATION) ) OR CR=CONTROL RELAY MCC MOTOR CONTROL CENTER <br /> K 14 DATA OUTLET ELECTRICAL POWER TRCONTACTOR <br /> ® MANUAL MOTOR STARTER FILTER MOM MILLION CIRCULAR MILS <br /> TR=TIME DELAY OR TIMING MLO MAIN LUGS ONLY <br /> M TRANSFORMER (SIZE AS SHOWN, IN KVA) 0 VOLUME CONTROL 2 RELAY <br /> NACB NON-AUTOMATIC CIRCUIT BREAKER <br /> T NEC NATIONAL ELECTRICAL CODE <br /> S SPEAKER, CEILING MOUNTED STARTER SIZE N.O. CONTACT N A NOT APPLICABLE <br /> O JUNCTION BOX O / <br /> FUSED SWITCH NO NORMALLY CLOSED <br /> ® EQUIPMENT CONNECTION El< LOWBAY SPEAKER, N.C. CONTACT NO NORMALLY OPEN <br /> (LOCATION DIAGRAMMATIC) HORN TYPE POWER FACTOR OFC I OWNER FURNISHED, <br /> CORRECTION CAPACITOR N.O. - ON DELAY CONTACT CONTRACTOR INSTALLED <br /> PUSHBUTTON STATION E]< MID HEIGHT SPEAKER DISCONNECT SWITCH PPA PAGING <br /> H PHASE SYSTEM <br /> OO 460 VOLT MOTOR (SIZE AS NOTED) M HORN TYPE I <br /> MOTOR HORSEPOWER N.C. - ON DELAY CONTACT PNL PANEL <br /> PSS PROGRAMMABLE SYSTEM SWITCH <br /> 4 208 VOLT OR 240 V MOTOR D CLUSTER HORNS GENERATOR PVC POLY-VINYL CHLORIDE (CONDUIT) <br /> (SIZE AS NOTED) �� N.C. - OFF DELAY CONTACT RF RETURN FAN <br /> SCHEMATIC RVNR REDUCED VOLTAGE, NON-REVERSING <br /> (� 115 VOLT MOTOR (SIZE AS NOTED) LIGHTINGN.C. - OFF DELAY CONTACT SRP SMOKE REMOVAL PANEL <br /> 0 POWER FACTOR CORRECTION CAPACITOR TRANSFER SWITCH DISCONNECT SWITCH SWBD SWITCHBOARD <br /> GR <br /> HIGH INTENSITY DISCHARGE (HID) SIF SUPPLY PP YFAN <br /> FIXTURE m FUSE B EIRE ALARM SYSTEM ST SHUNT TRIP CIRCUIT BREAKER <br /> CONDUIT NOT BURIED TBD TO BE DETERMINED <br /> (INCLUDING ABOVE SUSPENDED I� °� FLOODLIGHT - WALL MTD. / POLE MTD. <br /> CEILING & UNDER RAISED FLOOR) ❑ DISCONNECT SWITCH CIRCUIT BREAKER EQ ELEVATOR ALARM BELL T.D. TIME DELAY <br /> THEN WIRE INSULATION TYPE REFER To N.E.C. <br /> LIGHTING FIXTURE - 2' x 4' AYIN FIRE ALARM HORN/STROBE, THWN WIRE INSULATION TYPE REFER TO N.E.C. <br /> --------- BURIED CONDUIT WIRING ® FLUORESCENT WITH 3 TUBES I <br /> INTERLOCK �'- EY 'J TRANSFORMER �� WALL OR CEILING TLC TOTAL LIGHTING CONTROL (BY G.E.) <br /> (UNDERGROUND & IN FLOOR SLAB) _ M=MECHANICAL OS SMOKE DETECTOR <br /> FLUORESCENT T/S TWISTED AND SHIELDED PAIR <br /> ® <br /> LIGHTING <br /> WTH 4TUB S <br /> URE 2LAYIN I E=ELECTRICAL UH UNIT HEATER <br /> FLEXIBLE METAL CONDUIT II TRANSFORMER (DASHED LINE GROUND CONNECTION OD DUCT SMOKE DETECTOR VHO VERY HIGH OUTPUT <br /> LIGHTING FIXTURE - 2' x 2' LAYIN O l l lJ l _ WP WEATHER PROTECTED <br /> CONDUIT HASH MARK DESIGNATIONS FLUORESCENT WITH 2 TUBES --' INDICATES ELECTROSTATIC O HEAT DETECTOR <br /> PHASE CONDUCTOR T� SHIELD) / PILOT LIGHT *NOTE: SEE SHEET E515 FOR ADDITIONAL FIRE <br /> NEUTRAL CONDUCTOR E� LIGHT FIXTURE - 1' x 4' SURFACE OR * INDICATES COLOR ® REMOTE RELAY ALARM ABBREVIATIONS. <br /> YGROUND CONDUCTOR PENDANT FLUORESCENT WITH 2 TUBES SURGE ARRESTER / <br /> '*—ISOLATED GREEN GROUND CONDUCTOR Q MANUAL STATION <br /> l <br /> CIRCUIT SOURCE LIGHTING FIXTURES WIRED IN MASTER/ CIRCUIT BREAKER W/ PUSHBUTTON ELECTRICAL OPERATOR � o- MOMENTARY CONTACT WFxX WATERFLOW SWITCH <br /> PANEL/CIRCUIT BREAKER N0.(S) rLLQLJ SLAVE BALLAST CONFIGURATION T NORMALLY OPEN "P" = PRESSURE TYPE, <br /> iD6-1/1,3,5 (3 2-LAMP BALLASTS FOR 2 3-LAMP E LT = LONG T.D. TRIP UNIT "PD" = PRESSURE TYPE W/DELAY <br /> FIXTURES) �/ v T � SHORT- INSTTA TT RUNIT <br /> TRIP UNIT PUSHBUTTON <br /> CONDUIT TURNS DOWN LIGHT FIXTURE - FLUORESCENT WITH Y LT GF = GND. FAULT TRIP UNIT MOMENTARY CONTACT PS HI/LO AIR PRESSURE SWITCH <br /> CONDUIT TURNS UP ©OR m ALL BALLASTS ON EMERGENCY CIRCUIT NORMALLY CLOSED ❑ ( <br /> VS TAMPER SWITCH VALVE SWITCH) <br /> CONDUIT ONLY LIGHT FIXTURE TAP 1/2" FLEXIBLE POTENTIAL TRANSFORMER OFF` 'ON SELECTOR SWITCH FFA-C-1 FIRE ALARM COMMUNICATOR <br /> C.O. ��7 METAL CONDUIT - 4 #12: TWO PHASE QUANTITY & RATIO 1 MAINTAINED CONTACT (CELLULAR DIALER) <br /> —E— EMERGENCY CIRCUIT CONDUCTORS, ONE NEUTRAL, ONE GROUND 480120 AS SHOWN FA-0- TWO POSITION#12 FOR SINGLE OR COMMON BALLAST 2 2 rr TC FIRE ALARM TERMINAL CABINET <br /> SWI <br /> —LV— LOW VOLTAGE CIRCUIT INDIRECT LIGHTING FIXTURE 1 FACP FIRE ALARM CONTROL PANEL <br /> ® CURRENT TRANSFORMER ���1 SELECTOR SWITCH <br /> —W— WIREMOLD 18000 SERIES DISTRIBUTION 3 800:5 QUANTITY & RATIO MAINTAINED CONTACT <br /> SYSTEM REF. E503 AS SHOWN -+-2 THREE POSITION <br /> EXIT SIGN, WALL MOUNTED �1� <br /> —W— EXISTING WIREMOLD 18000 SERIES /� AS AMMETER w/SWITCH <br /> DISTRIBUTION SYSTEM ®i EXIT SIGN, CEILING MOUNTED <br /> e �/ VS VOLTMETER w/SWITCH SOLENOID VALVE , / <br /> FIXTURE IDENTIFICATION <br /> Y "X" DENOTES FIXTURE TYPE PRESSURE SWITCH - N.C. <br /> Y" DENOTES TOTAL FIXTURE WATTAGE WHM WATTHOUR METER OPENS ON RISING PRESSURE <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE AWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> ACCEPTABILITY J.S. 08/21/23 ELECTRICAL LEGEND 30397566 B 08/22/23 <br /> A EVERETT FIRE PANEL REPLACEMENT— XX W2640474 SAZAN/ZO 02/13/23 S,THIS DESIGN AND/OR CHECKED ECIFICATION IS APPROVED K.M. 08/22/23 SHEET SEQUENCE NO. <br /> BOE/A/G m ENGINEER C <br /> B EVERETT FIRE PANEL REPLACEMENT— 40-01/07 30397566 AGOW/JS 08/21/23 APPROVED BY DEPT. DATE K.M. 08/17/23 TITLE EVERETT FIRE PANEL REPLACEMENT <br /> z3 C <br /> CHECKED O <br /> al <br /> me. APPROVED BUILDING 40-001 <br /> APPROVED EVERETT, WA. DWG No. 40-001-EO <br />
The URL can be used to link to this page
Your browser does not support the video tag.