Laserfiche WebLink
9' 98 7 6 5' 5 LEGEND <br /> SEE SHEET EO FOR LEGEND AND ABBREVIATIONS <br /> MATCH LINE SEE DWG 40-001-1E262 C <br /> I <br /> GENERAL NOTES <br /> STORAGE AREA <br /> w <br /> w o <br /> 0 <br /> o <br /> 0 <br /> REFERENCE DRAWINGS <br /> 1"C, 24#14 <br /> w w <br /> PHI <br /> w z <br /> w <br /> z <br /> U <br /> H <br /> Q <br /> B <br /> A CONSTRUCTION NOTES <br /> PROVIDE DIGITAL ADDRESSABLE FIRE ALARM CONTROL <br /> PANEL. CONNECT ALL MONITORING POINTS AS SHOWN <br /> ON POINTS LIST LIST TO THIS PANEL. THIS PANEL WILL <br /> BECOME THE BUILDING FACP FOR 40-01/07. LABEL <br /> PANEL EVi-FA-40-01/07. COORDINATE 120VAC <br /> REQUIREMENTS WITH E60 SERIES SHEETS AND PANEL <br /> 73 SCHEDULE UPDATES WITH BOEING ELECTRICAL ENGINEER <br /> MATT KENT 425.299.4719. <br /> c CONNECT EXISTING DEVICE TO NEW BUILDING FACP. <br /> UTILIZE EXISTING INFRASTRUCTURE. PROVIDE CONDU T <br /> AND CONDUCTORS AS REQUIRED. <br /> WOMEN --11 PROVIDE MONITORING DEVICES ON EXISTING SPRINKLER <br /> 106 G--� RISER. CONNECT TO NEW BUILDING FACP. UTILIZE <br /> O O L---4I EXISTING INFRASTRUCTURE. PROVIDE CONDUIT AND <br /> II A CONDUCTORS AS REQUIRED. SEE DETAIL 1/E515 FOR <br /> ❑ &L--J 1/2"C-2,#12 TO J-BOX <br /> INSTALLATION NOTES. <br /> JANITOR D PNL. XS2V01-2C9 is D ® PROVIDE ADDRESSABLE MANUAL PULL STATION. PROVIDE <br /> & STORAGE SVI-5 WF PRESSURE 3/4"C, 22/10C CONDUIT, CONDUCTORS AND CONNECTION TO NEW <br /> 5�SMK @ FACP L1:029s -1:013- BUILDING FACP. <br /> 1"C, 22#14 PROVIDE ADDRESSABLE SMOKE DETECTOR. PROVIDE <br /> ®MAN PULL @ FACP L1:028 F FAC FACP FPD CONDUIT, CONDUCTORS AND CONNECTION TO NEW <br /> A BUILDING FACP. <br /> 6 LL IALER FAIL L1:030 F SV1-5 WF ISO 3/4"C, 8#14 © PROVIDE CELLULAR COMMUNICATOR. SEE DETAILS 3 AND <br /> TAMPER L1:014 <br /> 4 ON SHEET E515 FOR INSTALLATION NOTES. <br /> 120V RISER SV1-5 TAMPER <br /> ALARM BELL L1:012 <br /> D 1/2°C, 2#14 0 <br /> PARTIAL PLAN VIEW N <br /> SCALE: 1/8"=1'-0" <br /> 1 E260 1E261 1E262 1E263 <br /> 1 E264 1E265 r///l/E//2I56//l1E267 <br /> KEY PLAN 0 <br /> 8' 4' 0 4' 8' 16' <br /> G.O.U.1� SCALE: 1/8"=I'-C" <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ACCEPTABILITY J,$, Ga 21 23 SUBTITLE CURRENT REVISION 30397566 SYMBOL ^ DATE 08/22/23 <br /> $ 22 23 <br /> A EVERETT FIRE PANEL REPLACEMENT- XX W2640474 SAZAN/ZO 02.13.23 THIS DESIGN AND/OR CHECKED FIRE ALARM SYSTEM PLAN-FIRST FLOOR LF J1 / / <br /> SPECIFICATION IS APPROVED K.M. 08/22/23 SHEET SEQUENCE NQ. <br /> B EVERETT FIRE PANEL REPLACEMENT- 40-01/07 30397566 ACOW JS 0a 2t 23 Q�BOE//VGA-:7 <br /> APPROVED BY DEPT. DATE IN—11K EVERETT FIRE PANEL REPLACEMENT 1 E266 <br /> / / / / K.M. 0& 17 23 <br /> CHECKED <br /> APPROVED BUILDING 40-001 JOB N0. 30397566 COMP N0. <br /> APPROVED COL. A-C/5-9 EVERETT, WA. DWG NQ. 40-001-1 E266 <br />