Laserfiche WebLink
Enphase Encharge 10 <br /> MODEL NUMBER <br /> ENCHARGE-10-1 P-NA Encharge 10 battery storage system with integrated Enphase Microinverters and battery <br /> management unit(BMU).Includes: <br /> Three Encharge 3.36 kWh base units(B3-A01-US001-1-3) <br /> One Encharge 10 cover kit with cover,wall mounting bracket,watertight conduit hubs,and <br /> interconnect kit for wiring between batteries(1310-C-1050-0) <br /> ACCESSORIES <br /> ENCHARGE-HNDL-R1 One set of Encharge base unit installation handles <br /> OUTPUT(AC) @ 240 VAC' <br /> Rated(continuous)output powerz 3.84 kVA <br /> Peak output power 5.7 kVA(10 seconds) <br /> Nominal voltage/range 240/211 —264 VAC <br /> Nominal frequency/range 60/57—61 Hz <br /> Rated output current 16A <br /> Peak output current 24.6A(10 seconds) <br /> Power factor(adjustable) 0.85 leading...0.85 lagging <br /> Maximum units per 20 A branch circuit 1 unit(single phase) <br /> Interconnection Single-phase <br /> Maximum AC short circuit fault current over 3 cycles 69.6 Arms <br /> Round trip efficiencyz 89% <br /> BATTERY <br /> Total capacity 10.5 kWh <br /> Usable capacity 10.08 kWh <br /> Round trip efficiency 96% <br /> Nominal DC voltage 67.2 V <br /> Maximum DC voltage 73.5 V <br /> Ambient operating temperature range -15°C to 55°C(5°F to 1310 F)non-condensing <br /> Optimum operating temperature range 0°C to 30°C(32°F to 86°F) <br /> Chemistry Lithium iron phosphate(LFP) <br /> MECHANICAL DATA <br /> Dimensions(WxHxD) 1070 mm x 664 mm x 319 mm (42.13 in x 26.14 in x 12.56 in) <br /> Weight Three individual 44.2 kg(97.4 lbs)base units plus 21.1 kg(48.7 lbs)cover and mounting <br /> bracket;total 154.7 kg(341 lbs) <br /> Enclosure Outdoor-NEMA type 3R <br /> IQ 8X-BAT microinverter enclosure NEMA type 6 <br /> Cooling Natural convection-No fans <br /> Altitude Up to 2500 meters(8200 feet) <br /> Mounting Wall mount <br /> FEATURES AND COMPLIANCE <br /> Compatibility Compatible with grid-tied PV systems.Compatible with Enphase IQ Series Micros,Enphase <br /> Enpower,and Enphase IQ Envoy for backup operation. <br /> Communication Wireless 2.4 GHz <br /> Services Backup,self-consumption,TOU,Demand Charge,NEM Integrity <br /> Monitoring Enlighten Manager and MyEnlighten monitoring options;API integration <br /> Compliance UL 9540,UN 38.3,UL 9540A,UL 1998,UL 991,NEMA Type 3R,AC156 <br /> EMI:47 CFR,Part 15,Class B,ICES 003 <br /> Cell Module:UL 1973,UN 38.3 <br /> Inverters:UL 62109-1,IEC 62109-2,UL 1741SA,CAN/CSA C22.2 No.107.1-16 <br /> LIMITED WARRANTY <br /> Limited Warranty3 >70%capacity,up to 10 years or 4000 cycles <br /> 1.Supported in backup/off grid operations <br /> 2.AC to Battery to AC at 50%power rating. <br /> 3.Whichever occurs first.Restrictions apply. <br /> To learn more about Enphase offerings,visit enphase.com <br /> ©2020 Enphase Energy.All rights reserved.Enphase,the Enphase logo,Encharge 10,and other trademarks or service names are the trademarks OZ E N P H A S E <br /> of Enphase Energy,Inc.Data subject to change.2020-05-19 `/ <br />