My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5103 S 4TH AVE 2024-03-05
>
Address Records
>
S 4TH AVE
>
5103
>
5103 S 4TH AVE 2024-03-05
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2024 11:03:06 AM
Creation date
2/8/2024 11:02:27 AM
Metadata
Fields
Template:
Address Document
Street Name
S 4TH AVE
Street Number
5103
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RM <br />PROJECT: MCLEAN * EGGERUNG'S <br />INTERIOR REMODEL <br />INTERIOR REMODEL PER PLAN. <br />SUBJECT SITE ADDRESS: <br />5 103 5 4th Ave Unit A 98203 <br />LEGAL DESCRIPTION: <br />Section 32 Township 29 Range 05 Quarter 5W <br />SOUTH FOURTH STREET CONDOMINIUM UNIT. <br />PARKING 4 TGW EQ 4 UND 50% INI IN COM AREAS 4 <br />PACS AS DE5C IN DECL REF REC Af. <br />PARCEL TAX ID #: 00917000000200 <br />CODES <br />201 8 International Buddmg Code (IBC) <br />201 8 International Mechanical Code (IMC) <br />201 8 International Fuel Gas Code (IFGC) <br />201 8 International Fire Code (I PC) <br />ZONING: <br />R2 <br />PRESENT USE: <br />SINGLE FAMILY <br />JURISDICTION: <br />SNOHOMISH <br />5TRucTuRE cIA55: Dwelling <br />STRUCTURE TYPE: 2 Story w/Basement <br />YEAR BUILT: 1990 <br />CARBON MONOXIDE DETECTORS: <br />Area Summa <br />s.f. <br />FOR NEW CONSTRUCTION, AN APPROVED CARBON MONOXIDE ALARM <br />�' <br />SHALL BE INSTALLED OUTSIDE OF EACH SEPARATE SLEEPING AREA IN <br />Floor 1 <br />1,125 <br />THE IMMEDIATELY VICINITY OF THE BEDROOMS IN DWELLING UNITS <br />Floor 2 <br />GOO <br />AND ON EACH LEVEL OF THE DWELLING AND IN ACCORDANCE WITH <br />Attached Garage <br />G24 <br />THE MANUFACTURES DIRECTIONS. <br />Total <br />2,350 <br />SMOKE DETECTORS: <br />VALUATION OF THE WORK: <br />CONSTRUCTION 4 MATERIAL $ 20,000 <br />ADMINISTRATION 2,500 <br />TOTAL $ 22,500 <br />CONTACTS INFORMATION <br />Owner: <br />Barbara McLean <br />Address: 5 103 5 4th Ave Unit A 95203 <br />Phone: 20G-488-3 103 <br />Email: kmde5i6jnO4@yahoo.com <br />Contractor: <br />Owner <br />Structural Desion Enoineer: <br />Ken Nguyen <br />Address: 17G 14 NE 29th 5t <br />Redmond, WA 96052 <br />Phone: 425-89 1-5 1 1 1 <br />Email: housede5ign4u@outlook.com <br />2436" <br />SMOKE ALARMS SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS: <br />1. IN EACH SLEEPING ROOM. <br />2. OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE <br />VICINITY OF THE BEDROOMS. <br />3. ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING <br />BASEMENTS, BUT NOT INCLUDING CRAWL5PACE5 AND <br />UNINHABITABLE ATTICS. IN DWELLINGS OR DWELLINGS UNITS WITH <br />SPLIT LEVELS AND WITHOUT AN INTERVENING DOOR BETWEEN <br />ADJACENT LEVELS, A SMOKE ALARM INSTALLED ON THE UPPER <br />FLOOR SHALL SUFFICE FOR THE ADJACENT LOWER LEVEL PROVIDE <br />THAT THE LOWER LEVEL IS LESS THAN ONE FULL STORY BELOW THE <br />UPPER LEVEL. <br />4. SMOKE DETECT05 TO BE HARWIRE, INTERCONNECTED WITH <br />BATTERY BACKUP. <br />RECESSED LIGhTING: (K402.4.4) <br />* RECESSED LUMINAIRES INSTALLED IN THE BUILDING THERMAL <br />ENVELOPE SHALL BE TYPE IC -RATED AND CERTIFIED UNDER A5TM <br />E283 AS HAVING AN AIR LEAKAGE RATE NOT MORE THAN 2 CFM <br />WHEN TESTED AT A 1.57 P5F PRESSURE DIFFERENTIAL AND SHALL <br />HAVE A LABEL ATTACHED SHOWING COMPLIANCE WITH THIS TEST <br />METHOD. ALL RECESSED LUMINAIRES SHALL BE SEALED WITH A <br />GASKET OR CAULK BETWEEN THE HOUSING AND THE INTERIOR WALL <br />OR CEILING COVERING. <br />PROGRAMMABLE THERMOSTAT. <br />WHERE THE PRIMARY HEATING SYSTEM 15 A FORCED -AIR FURNACE, AT <br />LEAST ONE THERMOSTAT PER DWELLING UNIT SHALL BE CAPABLE OF <br />CONTROLLING THE HEATING AND COOLING SYSTEM ON A DAILY <br />SCHEDULE TO MAINTAIN DIFFERENT TEMPERATURE SET POINTS AT <br />DIFFERENT TIMES OF THE DAY. THE THERMOSTAT SHALL ALLOW FOR, <br />AT A MINIMUM, A 5-2 PROGRAMMABLE SCHEDULE <br />(WEEKDAY5/WEEKEND5) AND BE CAPABLE OF PROVIDING AT LEAST <br />TWO PROGRAMMABLE SETBACK PERIODS PER DAY. THIS <br />THERMOSTAT SHALL INCLUDE THE CAPABILITY TO SET BACK OR <br />TEMPORARILY OPERATE THE SYSTEM TO MAINTAIN ZONE <br />TEMPERATURES DOWN TO 55°F (I 3°C) OR UP TO 85°F (29°C). THE <br />THERMOSTAT SHALL INITIALLY BE PROGRAMMED WITH A HEATING <br />TEMPERATURE SET POINT NO HIGHER THAN 70'f (2I'C) AND A <br />COOLING TEMPERATURE SET POINT NO LOWER THAN 78°F (2G'C). THE <br />THERMOSTAT AND/OR CONTROL SYSTEM SHALL HAVE AN ADJUSTABLE <br />DEADBAND OF NOT LE55 THAN I 0°F. <br />SEALING (R403.2.2) <br />DUCTS, AIR HANDLERS, AND FILTER BOXES SHALL BE SEALED. JOINTS <br />AND SEAMS SHALL COMPLY WITH EITHER THE INTERNATIONAL <br />MECHANICAL CODE OR INTERNATIONAL RESIDENTIAL CODE, AS <br />APPLICABLE. <br />BUILDING CAVITIES (R403.2.3) <br />BUILDING FRAMING CAVITIES SHALL NOT BE USED AS DUCTS OR <br />PLENUMS. INSTALLATION OF DUCTS IN EXTERIOR WALL5, FLOORS OR <br />CEILINGS SHALL NOT DISPLACE REQUIRED ENVELOPE INSULATION. <br />MECHANICAL SYSTEM PIPING INSULATION (R403.3) <br />MECHANICAL SYSTEM PIPING CAPABLE OF CARRYING FLUIDS ABOVE <br />1 O5°F (41 °C) OR BELOW 55°F ( 13°C) SHALL BE INSULATED TO A <br />MINIMUM OF R-G. <br />NOTES: <br />ELECTRICAL OR PLUMBING UNDER SEPARATE PERMIT. <br />ALL REPLACED EGRESS WINDOWS AND DOORS REQUIRED INSPECTION. <br />EXISTING CEILING, WALL OR FLOOR CAVITIES EXPOSED DURING <br />CONSTRUCTION PROVIDED THESE CAVITIES ARE FILLED WITH INSULATIONS, <br />SHALL BE REIN5ULATED AS FOLLOWS: <br />Wood Wall Use R-2 1 plus R-1 2 ci <br />Basement Wall Use R-2 1 plus R- 12 ci <br />Slab on Grade R- 10 perimeter and under entire slab <br />Below Grade R-10 perimeter and under entire slab <br />floor Use R-38 <br />Vicinity Map <br />NITS <br />NT Engineers — — 17614 NE 29th St - Redmond WA 98052 — — housedesign4u@outlook.com —*-- 425-900-7666 or 425-891-5111 <br />Page Index: <br />I. I -General Notes <br />2. 1 - (Ex) Floors Plans <br />2.2 - (Pr) Floors Plans <br />2.3 - Framing Plans <br />oN <br />�^ 4 6 • H����� <br />41 <br />� <br />\\4586 � �s{r 'GtS <br />�jONAL E� <br />09/21/21 <br />ggerling's Interior Remodel <br />DATE <br />09-21 <br />5103 S 4th Ave - Unit A <br />2021 <br />Everett WA 98203 <br />[GENERAL <br />SHEET <br />1 •1 <br />x36 <br />NOTES <br />
The URL can be used to link to this page
Your browser does not support the video tag.