STRUCTURAL NOTES <br />CODES AND SPECIFICATIONS <br />1. INTERNATIONAL BUILDING CODE, 2018 EDITION, ASCE 7-16 <br />2. INTERNATIONAL RESIDENTIAL CODE, 2018 EDITION <br />3. SIMPSON STRONG TIE WOOD CONTRUCTION CONNECTORS 2021-2023 <br />4. FASTENERS IN CONTACT WITH PRESSURE TREATED WOOD MUST BE STAINLESS STEEL, ZMAX(G185HDG PER ASTM A653), <br />BATCH/POST HOT -DIP GALVANIZED (PER ASTM 8695, CLASS 55 OR GREATER). UNCOATED AND PAINTED PRODUCTS SHOULD <br />NOT BE USED WITH TREATED WOOD. WHEN USING STAINLESS STEEL HOT -DIP GALVANIZED CONNECTORS, THE <br />CONNECTORS AND FASTENERS SHOULD BE MADE OF THE SAME MATERIAL. <br />DESIGN CRITERIA <br />1, WIND LOAD: INTERNATIONAL BUILDING CODE, 2018, ASCE 7-16, ALTERNATE ALL -HEIGHTS METHOD, ULTIMATE DESIGN WIND <br />SPEED = 110 MPH, NOMINAL DESIGN WEND SPEED = 85 MPH, EXPOSURE B <br />SEISMIC: INTERNATIONAL BUILDING CODE, 2018, ASCE 7-16 <br />RISK CATEGORY II <br />SEISMIC IMPORTANCE FACTOR, Ie=1.0 <br />MAPPED SPECTRAL RESPONSE ACCELERATION PARAMETERS, Ss=1.5, S1=0.5 <br />SITE CLASS D <br />DESIGN SPECTRAL RESPONSE ACCELERATION PARAMETERS, Sds=1.09, Sd1=0.59 <br />SEISMIC DESIGN CATEGORY D2 <br />BASIC SEISMIC FORCE -RESISTING SYSTEM: LIGHT FRAME WALLS WITH WOOD SHEAR WALLS <br />DESIGN BASE SHEAR, V : F (Sds) (W) / R = 0.1846 (%M <br />RESPONSE MODIFICATION COEFFICIENT, R=6.5 <br />ANALYSIS PROCEDURE USED: SIMPLIFIED ALTERNATIVE STRUCTURAL DESIGN FOR SIMPLE BEARING WALL SYSTEMS <br />3. ROOF LOAD: DL = 15 PSF LL = 25 PSF (ROOF SNOW LOAD) <br />4. FLOOR LOAD: DL = 10 PSF LL =40 PSF <br />5, DECK LOAD: DL = 10 PSF LL = 40 PSF <br />6. SOILS: ASSUMED 1500 PSF ALLOWABLE SOIL BEARING <br />ASSUMED 30 PCF ACTIVE SOIL PRESSURE, 300 PCF PASSIVE PRESSURE, 0.35 COEFFICIENT OF FRICTION <br />ALL FOOTINGS AND SLABS SHALL BEAR ON UNDISTURBED SOIL OR FILL COMPACTED TO 95% MODIFIED <br />PROCTOR. <br />7. CONCRETE: 3000 PSI @ 28 DAYS (2500 PSI USED FOR DESIGN) <br />GRADE 40 REINFORCEMENT <br />MINIMUM 3" COVER FOR ALL REINFORCEMENT EXCEPT AS NOTED AT RETAINING WALLS OR OTHER <br />DETAILS <br />TIMBER CONSTRUCTION NOTES <br />1. LUMBER GRADES AND ALLOWABLE STRESSES SHALL BE AS FOLLOWS UNLESS NOTED OTHERWISE ON PLAN: <br />ALL SAWN LUMBER HF#2 OR BETTER, <br />Fb = 875 PSI, Fv = 75 PSI, E = 1,300,000 <br />GLULAM BEAMS 24F-V4, Fb = 2400 PSI, Fv = 165 PSI, E = 1,800,000 <br />MICROLAM, LVL Fb = 2600 PSI, Fv = 285 PSI, E=1,900,000 <br />PARALLAMS, PSL Fb = 2600 PSI, Fv = 290 PSI, E = 2,000,000 <br />2. WHEN TOP PLATE IS INTERRUPTED BY HEADER, HEADER SHALL HAVE STRAP CONNECTORS TO THE TOP PLATE EACH END, <br />USE 2-SIMPSON MSTA24 CONNECTORS, UNLESS NOTED OTHERWISE. <br />3. ALL SHEAR WALL SHEATHING NAILS AND ANCHORS SHALL BE AS DETAILED ON THE DRAWINGS AND AS NOTED IN THE <br />SHEAR WALL SCHEDULE, <br />4. FLOOR SHEATHING SHALL BE %" MINIMUM APA RATED FLOOR SHEATHING WITH 10d COMMON @ 6" OC AT ALL SUPPORTED <br />PANEL EDGES AND 10d @ 12" OC AT INTERMEDIATE SUPPORTS. <br />5. ROOF SHEATHING SHALL BE 7116" MINIMUM APA RATED ROOF SHEATHING WITH 8d COMMON @ 6" OC AT ALL SUPPORTED <br />PANEL EDGES AND 8d @ 12" OC AT INTERMEDIATE SUPPORTS. <br />GENERAL CONSTRUCTION NOTES <br />1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD. ANY VARIATIONS FROM THE DRAWINGS SMALL BE BROUGHT TO <br />THE ATTENTION OF THE DESIGNER OR THE ENGINEER. <br />2. ADEQUATE SHORING AND BRACING OF ALL STRUCTURAL MEMBERS DURING CONSTRUCTION SHALL BE PROVIDED. ANY <br />PROPOSED FIELD CHANGES MUST HAVE THE APPROVAL OF THE ENGINEER PRIOR TO CONSTRUCTION. <br />