24'-0' <br />25-B' <br />NOTES: <br />1. SMOKE AND CO ALARMS MUST BE HARDWIRED, INTERCONNECT <br />BACK—UP BATTER POWER. ALARM CLEARANCES MUST COMPLY <br />R314.3.1. <br />11-3' <br />22-10' <br />r— — — — — — — — — — — — — — — -- — — — — — — — — — — — — — — <br />I <br />ED AND PROVIDED WITH 24X24 XO 24X24 XO <br />WITH R314.3 ITEM 4 AND <br />I I I <br />I I I <br />I I I <br />I I <br />x OFFICE <br />rn <br />a BEDROOM x <br />X <br />a rn I <br />N X <br />I SD SD � <br />I <br />I <br />I <br />I x I <br />a BATHRO <br />N W/ NEW <br />r <br />— --------------------------------- <br />---------- <br />I <br />\ <br />96X84 OHO <br />6OX36 XO <br />W/D RELOCATED <br />FROM GARAGE <br />�� <br />DO <br />REF <br />I <br />� <br />I <br />I <br />36X80 <br />�� KITCHEN W/ NEW <br />I <br />FIXTURES <br />DW <br />I <br />LIVING ROOM <br />I <br />II <br />OC° <br />GARAGE <br />PRIMARY BEDROOM <br />------- <br />SDC <br />-- <br />II <br />0 <br />---- <br />-i <br />12'-4' <br />o <br />x <br />I <br />I <br />� <br />0 I <br />� <br />RELOCIATED WALL <br />� <br />i I <br />I <br />-- <br />I <br />----------------- <br />-------------- <br />-- <br />I <br />IN —FILLED DOOR <br />I <br />II <br />j <br />i� <br />I <br />I <br />IN —FILLED DOOR <br />6OX48 XO 6OX48 XO <br />O <br />i <br />----------------J-----------------J <br />r-- 60X80 SGD---� <br />I <br />IN —FILLED DOOR <br />M <br />PRIMARFFIXTURES <br />W/NEW <br />ED <br />FAN <br />I <br />I <br />I <br />O <br />I <br />I <br />I <br />I <br />L— <br />— — — — — — — — — — — — — — — — — — — — — — <br />— — — — — — — — — — — — <br />I <br />— L <br />25'-B' 1 9'-4' 1 24'-9' <br />REVISED FLOOR PLAN <br />4 <br />NOTE: NEW WALLS AND INFILL WALLS SHALL BE 2X4@16"OC WITH NAILING PER MINIMUM <br />REQUIREMENTS IN THE 2018 IRC SECTIONS R106.1.1NAD R301.1 <br />NOTE: NO EXTERIOR WALL DOORS OR WINDOWS ARE BEING MODIFIED. THE INTERIOR WALL <br />BETWEEN THE KITCHEN AND LIVING ROOM THAT WAS OPENED UP BY A PREVIOUS OWNER IS <br />NOT A BRACED WALL LINE. THERE ARE NO MODIFICATIONS TO THE ORIGINAL BRACED WALL LINES <br />AND THEREFORE NO SHEAR WALL BRACING MODIFICATIONS ARE REQUIRED. <br />31'-8' <br />ROOF CONSTRUCTION: <br />8' S" — COMPOSITION ROOFING <br />— 30# FELT <br />?g" MIN APA RATED SHEATHING <br />RAFTERS & CEILING JOISTS PER PLAN <br />— R49 MIN. INSULATION <br />— }" GWB <br />MAIN FLOOR CONSTRUCITON: <br />J" T&G APA RATED FLOOR SHEATHING <br />— FLOOR JOISTS PER PLAN <br />— R30 INSULATION <br />WALL CONSTRUCTION: <br />LAP SIDING OR BOARD AND BATTEN SIDING <br />— BUILDING WRAP <br />— 2XSTUDS 0 16"OC <br />R21 INSULATION MIN. <br />}" GWB <br />BUILDING CROSS SECTION <br />General Notes <br />E NO <br />e was' <br />pE Nc 2 <br />H 2 <br />IL <br />4 25839 C <br />RfCWEM1E�G\��� <br />S�ONAIEN <br />,. <br />Revision/Issue <br />Date <br />F_ N°ree °°d Ad -- <br />MDT ENGINEERING <br />31403 44TH AVE S <br />AUBURN, WA 98001 <br />253-709-9852 <br />MD.THOMPSON@EARTHLINK.NET <br />Project Name and Address <br />AURIOL <br />6902 COLUMBIA CT <br />EVERETT, WA 98203 <br />Project <br />sM1 1 <br />AURIOL <br />2 <br />Dodd <br />2/11/22 <br />sro�e <br />1 /4"=1 ' <br />