AURIOL/6902 COLUMBIA CT <br />STRUCTURAL NOTES <br />CODES AND SPECIFICATIONS <br />1. INTERNATIONAL BUILDING CODE, 2018 EDITION, ASCE 7-16 <br />2. INTERNATIONAL RESIDENTIAL CODE, 2018 EDITION <br />3. SIMPSON STRONG TIE WOOD CONSTRUCTION CONNECTORS 2021-2023 <br />4. FASTENERS IN CONTACT WITH PRESSURE TREATED WOOD MUST BE STAINLESS STEEL, ZMAX(G185HDG PER ASTM A653). <br />BATCH/POST HOT -DIP GALVANIZED (PER ASTM B695, CLASS 55 OR GREATER). UNCOATED AND PAINTED PRODUCTS SHOULD NOT <br />BE USED WITH TREATED WOOD. WHEN USING STAINLESS STEEL HOT -DIP GALVANIZED CONNECTORS, THE CONNECTORS AND <br />FASTENERS SHOULD BE MADE OF THE SAME MATERIAL. <br />DESIGN CRITERIA <br />1. WIND LOAD: INTERNATIONAL BUILDING CODE, 2018, ASCE 7-16, ALTERNATE ALL -HEIGHTS METHOD, ULTIMATE DESIGN WIND <br />SPEED = 110 MPH, NOMINAL DESIGN WIND SPEED = 85 MPH, EXPOSURE B <br />2. SEISMIC: INTERNATIONAL BUILDING CODE, 2018, ASCE 7-16 <br />RISK CATEGORY II, SEISMIC IMPORTANCE CATEGORY, Ie=1.0 <br />MAPPED SPECTRAL RESPONSE ACCELERATION PARAMETERS, S-1.5, S1=0.5 <br />SITE CLASS D <br />DESIGN SPECTRAL RESPONSE ACCELERATION PARAMETERS, Sd-1.09, Sd=0.5g <br />SEISMIC DESIGN CATEGORY, D2 <br />BASIC SEISMIC FORCE -RESISTING SYSTEM: LIGHT FRAME WALLS WITH WOOD SHEAR WALLS <br />DESIGN BASE SHEAR, V + F(Sds)(W)/R = 0.1846W <br />RESPONSE MODIFICATION COEFFICIENT, R=6.5 <br />ANALYSIS PROCEDURE USED: SIMPLIFIED ALTERNATIVE STRUCTURAL DESIGN FOR SIMPLE BEARING WALL SYSTEMS <br />3. ROOF LOAD: OIL = 15 PSF ILL = 25 PSF (ROOF SNOW LOAD) <br />4. FLOOR LOAD: DL = 10 PSF ILL = 40 PSF <br />5. DECK LOAD: DL = 10 PSF ILL = 60 PSF <br />6. SOILS: ASSUMED 1500 PSF ALLOWABLE SOIL BEARING <br />ASSUMED 35 PCF ACTIVE SOIL PRESSURE, 350 PCF PASSIVE PRESSURE, 0.35 COEFFICIENT OF FRICTION <br />ALL FOOTINGS AND SLABS SHALL BEAR ON UNDISTURBED SOIL OR FILL COMPACTED TO 95% MODIFIED PROCTOR. <br />7. CONCRETE: 3000 PSI ® 28 DAYS (2500 PSI USED FOR DESIGN) <br />GRADE 40 REINFORCEMENT <br />MINIMUM 3" COVER FOR ALL REINFORCEMENT EXCEPT AS NOTED AT RETAINING WALL OR OTHER DETAILS. <br />TIMBER CONSTRUCTION DETAILS <br />1. LUMBER GRADES AND ALLOWABLE STRESSES SHALL BE AS FOLLOWS UNLESS NOTED OTHERWISE ON PLANS: <br />ALL SAWN LUMBER HF#2 OR BETTER, Fb = 875 PSI, Fv 75 PSI, E = 1,300,000 <br />GLULAM BEAMS 24F-V4, Fb = 2400 PSI, Fv = 165 P51, E = 1,800,000 <br />MICROLAM, LVL Fb 2600 PSI, Fv = 285 PSI, E = 1,900,000 <br />PARALLAMS, PSL Fb = 2600 PSI, Fv = 290 PSI, E = 2,900,000 <br />2. WHEN TOP PLATE IS INTERRUPTED BY HEADER, HEADER SHALL HAVE STRAP CONNECTORS TO THE TOP PLATE EACH END. USE <br />2_ SIMPSON MSTA24 CONNECTORS, UNLESS NOTED OTHERWISE. <br />3. NO MODIFICATIONS TO EXTERIOR WALL, DOORS OR WINDOWS. THEREFORE, NO FIELD REVISIONS ARE REQUIRED TO EXISTING BRACED <br />WALL PANELS. <br />4. FLOOR SHEATHING SHALL BE J" MINIMUM APA RATED FLOOR SHEATHING WITH 10d COMMON ® 6"OC AT ALL SUPPORTED PANEL <br />EDGES AND 10d ® 12"OC AT INTERMEDIATE SUPPORTS. <br />5. ROOF SHEATHING SHALL BE J" MINIMUM APA RATED ROOF SHEATHING WITH 8d COMMON ® 6"OC AT ALL SUPPORTED PANEL EDGE <br />AND 8d ® 12"OC AT INTERMEDIATE SUPPORTS. <br />GENERAL CONSTRUCTION NOTES <br />1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD. ANY VARIATIONS FROM THE DRAWINGS SHALL BE BROUGHT TO THE <br />ATTENTION OF THE DESIGNER OR THE ENGINEER OF RECORD. <br />2. ADEQUATE SHORING AND BRACING OF ALL STRUCTURAL MEMBERS DURING CONSTRUCTION SHALL BE PROVIDED. <br />3. ANY PROPOSED FIELD CHANGES MUST HAVE THE APPROVAL OF THE ENGINEER OF RECORD PRIOR TO CONSTRUCTION. <br />1. EXISTING STUD WALL <br />2, 7/16" MIN. APA RATED WALL SHEATHING <br />1. EXISTING SLAB ON GRADE <br />2 <br />1 W/ 8d®6"OC AT PANEL EDGES <br />2. 2x STUD WALL <br />3. EDGE NAILING ® BOTTOM <br />6 2 3. EDGE NAILING ® BOTTOM <br />PLATE AND SILL PLATE <br />PLATE AND SILL PLATE <br />4. 2x TREATED PLATE W/ 1/2" DIA <br />4. 2. TREATED PLATE W/ 1/2" CIA <br />5 ANCHOR BOLTS ® 48" OC <br />ANCHOR BOLTS ® 48" OC <br />5. EXISTING FLOOR JOISTS PER PLAN <br />5. EXISTING FOUNDATION <br />6. EXISTING FOUNDATION <br />3 4 <br />3 4 <br />1 <br />u-LLL-111 <br />- <br />=1I1=1I <br />_ <br />11=1 s i <br />LI,,III, <br />7 <br />0. <br />O <br />el/4..-1. <br />1. ROOF RAFTERS PER PLAN <br />1. EXIST. 7/16" APA RATED SHEATHING <br />2. SIMPSON H2.5 ® EACH RAFTER <br />3 W/8"6' OC AT PANEL EDGES <br />3. ROOF SHEATHING <br />4 <br />4. 2x BLOCKING W/ 8d ®6" O.C. <br />2. EXISTING RAFTERS &CEILING JOISTS <br />1 5. 7/16" APA RATED SHEATHING W/ <br />3 8d®6" OC AT PANEL EDGES <br />2 3. EXIST. 2X BLOCKING W/8d NAILS ® 6" <br />O.C. <br />4. EXIST. 2X4 ® 24"OC <br />4 2 <br />5 <br />1 <br />I <br />l3/4"=1'-0" <br />Jy l <br />V E THp <br />WASNv�CS- <br />L 25839 ? <br />9p.� RfG'STE9E� \��W <br />S/ONAl- <br />�J N <br />N � <br />of t <br />z 0 <br />00 o <br />W Q 0 O <br />z�Q� 0 <br />Z N z 0 oo <br />E <br />W ,t- m W p <br />Z <br />� Q O � <br />0_ J <br />Q <br />W <br />REVISION DATES: <br />Q <br />� <br />J <br />H <br />Q <br />LJ <br />D_ <br />LJ <br />LJ <br />H <br />!n <br />U <br />W Q <br />� <br />O <br />o m <br />z <br />o :�i <br />J <br />:7i =) <br />a <br />LJ J <br />0_ O <br />w <br />J U <br />H <br />O <br />N <br />- U <br />Wo O <br />O <br />J <br />H- <br />a cD <br />co <br />SCALE: <br />DATE: <br />NO SCALE <br />2-11-22 <br />DRAWN BY: <br />SHEET NO. <br />MDT <br />C <br />PROJECT NO. <br />AURIOL <br />J <br />