'4' GENERAL NOTES:
<br /> • L DO NOT SCALE DRAWINGS.
<br /> i, 2. ALL WORKMANSHIP SHALL BE OF THE HIGHEST QUALITY "1). 134
<br /> } AND SHALL BE IN ACCORDANCE WITH ALL Q, a ywASR�1
<br /> MANUFACTURERS' SPECIFICATIONS,DIRECTIONS AND ''� I'll, .,?i n
<br /> RECOMMENDATIONS.THE '4
<br /> E WORK SHALL ALSO BE IN STRICT ' NA JOB No. 19190 SHEET 1 OF 2
<br /> CONFORMANCE WITH INDUSTRY STANDARDS AND COMPLY c� 0
<br /> WITH SOUND ENGINEERING AND CONSTRUCTIONam : y JOB NAME: THOMPSON RESIDENCE
<br /> PRACTICES. THE CONTRACTOR SHALL REPLACE ,�� , *
<br /> PORTIONS OF THE INSTALLED WORK THAT DOES NOT FLOOR PLANS
<br /> MEET.THESE REQUIREMENTS AT THEIR EXPENSE. AI
<br /> 3. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH #44tt
<br /> 45415 .4,',` ' MA ENGINEERING TECHNOLOGIES, INC. COMP. BY: S. GEORGIEFF DATE22 JULY, 2019 CHK. BY RPS
<br /> APPLICABLE FEDERAL,STATE AND LOCAL LAWS,AND IN GZSl'I,'0 s,.
<br /> ACCORDANCE WITH CURRENT CODE REQUIREMENTS. ."'$10 L E 2150 North 107th Street - Suite 320 Seattle, Washington 98133-9009
<br /> 4. THE CONTRACTOR SHALL COORDINATE ALL REQUIRED Telephone: [206] 281-7500 Facsimile: [206] 281-4611
<br /> LOCAL JURISDICTION INSPECTIONS AND SPECIAL Nationwide: [800] 621-7300
<br /> INSPECTIONS. THE CONTRACTOR SHALL PROVIDE 3 ` a a a o t4}
<br /> COPIES OF THE INSPECTION REPORTS THE OWNER
<br /> 5. ALL NEW AND/OR REPLACEMENT MATERIALS SHALL BE
<br /> EQUAL OR BETTER IN KIND AS EXISTING MATERIALS
<br /> 6. CONTACT THIS OFFICE AT (206)281-1500 IF ANY SITE CONDITIONS, SAFETY AND DEMOLITION: WORK THIS PERMIT,
<br /> ADDITIONAL DAMAGE IS FOUND OUTSIDE THIS SCOPE OF I. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE SHOWN SHADED
<br /> WORK DURING DEMOLITION OR ANY VARIATIONS TO THE FOR THE CONDITIONS AT THE JOB SITE, INCLUDING THE EXIST.
<br /> SITE OR EXISTING BUILDING ARE FOUND DURING THE SAFETY OF ALL PERSONS AT THE JOB SITE DURING THE ill
<br /> CONSTRUCTION WORK. PERFORMANCE OF THE WORK.. THIS REQUIREMENT LANDSCAPING
<br /> FIRE PROTECTION NOTES: SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TOAIISSiMISII 0,74,
<br /> SMOKE DETECTORS: NORMAL WORKING HOURS. EXIST.
<br /> 2. THE CONTRACTOR SHALL PROVIDE ACCEPTABLE , 1
<br /> SMOKE DETECTORS SHALL CONFORM TO REQUIREMENTS T �I GARAGE
<br /> SAFETY AND.SECURITY MEASURES AND SHALL MAINTAIN
<br /> OF OR IBC SECTION 9012.112 THROUGH 9012.11.4 OR IRC SAFETY AND SECURITY AT THE JOB SITE DURING THE 'Q v-
<br /> SECTION R314 AND THE FOLLOWING SPECIFICATIONS: II� _
<br /> • SMOKE DETECTORS SHALL BE HARD WIRED TO THE ENTIRE COURSE OF THE PROJECT. "
<br /> 3. THE CONTRACTOR SHALL PROVIDE TEMPORARY t30 -0
<br /> BUILDING ELECTRICAL SYSTEM AND SHALL BEW f
<br /> INTERCONNECTED IN SUCH A MANNER THAT THE BARRICADES AND OTHER FORMS OF PROTECTION TO ( I43 ® ®®®®® EXIST.
<br /> ACTIVATION OF ONE ALARM WILL ACTIVATE ALL OF THE PROTECT THE PUBLIC FROM INJURY DUE TO O PARKING
<br /> ALARMS IN THE INDIVIDUAL UNIT. DEMOLITION AND REPAIR WORK BARRICADES ARE TO 71-
<br /> REMAIN IN PLACE AFTER DEMOLITION WORK HAS BEEN V U 1 - n �,
<br /> • ALARMS SHALL COMPLY WITH UL 2n COMPLETED AND THROUGHOUT THE DURATION OF THE
<br /> • ALARMS SHALL BE INSTALLED IN ACCORDANCE WITH WORK- •, A 0
<br /> NFPA 12 AND MANUFACTURER'S RECOMMENDATIONS 4. THE CONTRACTOR SHALL REASONABLY SECURE
<br /> SMOKE DETECTORS SHALL BE INSTALLED IN THE SCAFFOLDING,WORK AREAS,BUILDING MATERIALS AND
<br /> FOLLOWING LOCATIONS: TOOLS FROM ACCESS TO THE PUBLIC AT ALL TIMES. JUL 2 4 2019
<br /> • IN EACH BEDROOM. 5. THE REQUIRED AND/OR IMPLIED DUTY OF PACIFIC CITY OF EVERETT
<br /> .,TO CONDUCT
<br /> CONSTRUCTION REVIEW OF THE CONTRACTOR'S
<br /> CARBON MONOXIDE ALARMS: PERFORMANCE DOES NOT,AND IS NOT INTENDED TO, FIN Permit Services
<br /> PROVIDE CARBON MONOXIDE ALARMS IN ACCORDANCE INCLUDE REVIEW OF THE ADEQUACY OF THE L(•1rE /�
<br /> WITH IBC SECTION 915,9152 THROUGH 9154 OR IRC SECTION CONTRACTOR'S SAFETY MEASURES IN,ON,OR NEAR THE �7 I pL I f�!
<br /> N 4
<br /> R315. CONSTRUCTION SITE. �� _ �� �� NOTE:
<br /> • SHALL BE CONNECTED TO THE BUILDINGS POWERSCALE: 1 30 -0
<br /> SOURCE. 6. THE CONTRACTOR AND THE SUB-CONTRACTORS SHALL VISIT THE SITE TO REVIEW THE EXISTING SITE,BUILDING THE INFORMATION ON THIS SITE PLAN IS
<br /> • ALARMS SHALL BE INSTALLED IN ACCORDANCE THE
<br /> MANUFACTURER'S INSTALLATION RECOMMENDATIONS. CONDITIONS,AND FEATURES, INCLUDING,BUT NOT SCHEMATIC AND HAS SEEN DERIVED
<br /> • COMBINATION CARBON MONOXIDE /SMOKE ALARMS LIMITED TO: GRADES,DIMENSIONS,ACCESS TO THE FROM THE SITE PLAN INFORMATION ON
<br /> SHALL COMPLY WITH UL 2034 AND UL 2n. WORK,POWER ACCESS,STAGING,REFUSE DISPOSAL, RECORD WITH EVERETT COUNTY,
<br /> CARBON MONOXIDE DETECTORS SHALL BE INSTALLED IN MATERIAL STORAGE,.ETC.
<br /> 1. THE CONTRACTOR SHALL PROVIDE HEAT AS AERIAL PHOTOGRAPHS AND SITE VISIT.
<br /> THE FOLLOWING LOCATIONS:
<br /> • IN THE IMMEDIATE VICINITY OUTSIDE EACH BEDROOM. THE
<br /> NECESSARY CONTRACTOR SHALL THE WPON
<br /> • ON EACH FLOOR OF THE BUILDING. 8. THE SHALL BE RESPONSIBLE FOR
<br /> DEMOLITION,TEMPORARY BRACING,METHODS,
<br /> TECHNIQUES,SEQUENCES AND PROCEDURES IN
<br /> NOTES: CONNECTION WITH THE WORK.
<br /> 1. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS 9. PROPERLY PROTECT OR CAP ALL UTILITIES THAT
<br /> AND DIMENSIONS. MIGHT BE DISTURBED DUE TO DEMOLITION ACTIVITY.
<br /> 2. ALL PARTITIONS ARE DIMENSIONED FROM FINISH FACE 10. PROTECT EXISTING FINISHES,FIXTURES,EQUIPMENT,ETC. + Reid lasPolte*
<br /> OF GYPSUM BOARD TO FINISH FACE OF GYPSUM THAT ARE TO REMAIN FROM DAMAGE DURING
<br /> BOARD UNLESS OTHERWISE NOTED (UNO). CONSTRUCTION
<br /> 3. ALL WORK SHALL BE ERECTED AND INSTALLED $UILDING ENVELOPE SPECIFICATIONS: MECHANICAL VENTILATION:
<br /> PLUMB.LEVEL,SQUARE AND TRUE.4. ALL DOORS SHALL HAVE 18" CLEAR ON THE STRIKE ENERGY CODE: PROVIDE SOURCE SPECIFIC FANS IN ACCORDANCE WITH WASHINGTON
<br /> SIDE OF DOOR.VERIFY AND ADVISE PACIFIC PROVIDE THERMAL INSULATION IN ACCORDANCE WITH 2015 WASHINGTON STATE MECHANICAL CODE. 1
<br /> ENGINEERING TECHNOLOGIES, INC.OF EXCEPTIONS STATE ENERGY CODE IN ACCORDANCE WITH RESIDENTIAL TABLE R402.1.I SOURCE SPECIFIC:
<br /> PRIOR TO BUILDING OUT PARTITIONS. RANGE HOOD 100 CFM
<br /> 5. ALL EXISTING AND NEW FLOOR PENETRATIONS FOR ATTIC R-49 BATHROOMS 50 CFM 1.0 SONE MAX.
<br /> PIPING SHALL BE FULLY PACKED AND SEALED IN EXTERIOR WALL (EXISTING) R-15 (2X4 FRAMING) LAUNDRY ROOMS 50 CFM 1.0 SONE MAX.
<br /> °la
<br /> ACCORDANCE WITH THE APPLICABLE BUILDING AND FLOORS OVER UNCONDITIONED SPACE R-30I
<br /> FIRE CODES. ACCESS HATCHES AND DOORS SAME AS SPACE ACCESSING I ' tO7
<br /> or 0 33
<br /> 6. ALL GLASS SHALL BE CLEAR TEMPERED GLASS,UNO. HVAC DUCTS DUCTS
<br /> (CRAWLSPACE SPACE OR ATTIC) R-8
<br /> • GLAZING TONG MARKS SHALL NOT BE VISIBLE.CLEAN EXHAUSTWATER PIPES OR ATTIC) R-4
<br /> AND POLISH ALL GLASS PRIOR TO PROJECT HOT PIPES R-4
<br /> DELIVERY AND AFTER INSTALLATION. A PERMANENT CERTIFICATE LISTING THEPREDOMINANT R-VALUES, ALL. IrFOR RATION ON THIS DOGJNOF
<br /> FNT
<br /> Y• 1. SHOULD SPECIFICATIONS OR MATERIALS QUESTIONS WINDOW AND DOOR U-VALUES,DUCT AND AIR LEAKAGE TESTINGIS PACIFICC EXCLUSIVE G ECi44O GI S,
<br /> ARISE,PLEASE CONTACT PACIFIC ENGINEERING RESULTS SHALL BE POSTED ADJACENT TO THE ELECTRICAL PANEL. ENGINEERING THT 201 OGRES, INC.
<br /> TECHNOLOGIES, INC. © COPYRIGHT 2018