Laserfiche WebLink
VERETT <br />0 <br />Permit Number: P2306-066 <br />Applied: 6/30/2023 <br />Issued: 8/8/2023 <br />Status: FINALED <br />Parent Permit: <br />Parent Project: <br />Details <br />Permit Inspections <br />City of Everett <br />Approved:8/8/2023 <br />Finaled: 9/25/2023 <br />Description: INSTALL (1) 2-COMP SINK, (3) HAND SINKS, REDIRECT <br />DRAIN <br />Site Address: 209 E CASINO RD SUITE B <br />City, State Zip Code: EVERETT, WA 98208 <br />Applicant: FELIPE HERNANDEZ <br />Owner: BJJ INVESTMENTS LLC <br />Contractor: TENANT W/ OWNER AUTHORIZATION <br />SCHEDULED DATE <br />COMPLETED DATE <br />TYPE <br />INSPECTOR <br />RESULT <br />REMARKS <br />9/20/2023 <br />9/20/2023 <br />PLUMB 08-FINAL** <br />MASON <br />CORRECTION <br />see notes <br />MORRISSEY <br />REQUIRED <br />Notes: <br />9/19/2023 9:22 AM Manuel Hernandez <br />Contact Name: Manuel Hernandez <br />Site Address: 209 E CASINO RD SUITE B <br />Phone:3609314238 <br />e-Mail: manuelhernandez.1989@gmail.com <br />- All hand sinks in front food prep area are to be plumbed direct with appropriate venting through the roof per the UPC chap 7 and 9.**** 704.3 <br />Commercial SinksExcept where specifically required to be connected indirectly to the drainage system, or when first approved by the authority having <br />jurisdiction, all plumbing fixtures, drains, appurtenances, and appliances shall be directly connected to the drainage system of the building or premises. - <br />Dipper well to be plumbed indirect with hub drain or equivalent. Hub drain to be vented per the UPC 801.3.3 Food -Handling Fixtures Food -pre paration <br />sinks, steam kettles, potato peelers, ice cream dipper wells, and similar equipment shall be indirectly connected to the drainage system by means of an <br />air gap.- Drain sizing per the UPC chapter 7.- Indirect drains for prep and three compartment sink cannot tie together and must run separately per the <br />UPC 801.3.3 Food Handling fixtures are to be piped separately to indirect drain receptor. <br />9/22/2023 <br />F9/22/2023 <br />PLUMB 08-FINAL** <br />MASON <br />CORRECTION <br />see notes <br />MORRISSEY <br />REQUIRED <br />Notes: <br />9/21/2023 10:57 AM Manuel Hernandez <br />Contact Name: Manuel Hernandez <br />Site Address: 209 E Casino Rd, Ste H <br />Phone:3602139277 <br />e-Mail: manuelhernandez.1989@gmail.com <br />- Use approved drainage fittings for vertical to horizontal and horizontal to horizontal changes of direction including venting below the flood rim of <br />fixtures per the UPC 706.1 Approved Fittings 905.3 Vent Pipe Rise- Dipper well hub drain is not vented as vent cannot exceed 5' from the trap outlet on <br />2" pipe per the UPC TABLE 1002.2HORIZONTAL LENGTHS OF TRAP ARMS- Vents cannot take of below the weir of the trap per the UPC 1002.4 Vent Pipe <br />OpeningThe vent pipe opening from soil or waste pipe, except for water closets and similar fixtures, shall not be below the weir of the trap.- Support <br />horizontal venting above grid and horizontal drain piping below grid every 4'. Mid story supports on vertical vent stacks per the UPC TABLE <br />313.3HANGERS AND SUPPORTS- Will need to run test all drainage piping in lieu of water test per the UPC 712.0 <br />I <br />Printed: Tuesday, 26 September, 2023 1 of 2 rk <br />SUPERION <br />