* * * * * Property of Engineers Northwest, Inc., P.S.- Use by others unlawful * * * * * <br />ASCE 7-16 <br />Seismic Loads per ASCE 7-16- Chapter 13 Seismic Design Requirements for Nonstructural Components <br />Input Cells = <br />Project Number: <br />22000043 <br />Project Name: <br />Fluke Calibration <br />Location: <br />Everett, WA <br />Design By: <br />MP <br />ASCE 7-16 Section 13.3 Seismic Demands on Nonstructural Components (Mechanical & Electrical Components) <br />All references below are to ASCE 7-16 (U.N.O.) <br />Mechanical and Electrical Component=lSpring isolated components and systems and vibration isolated flo <br />usina built-in or separate elastomeric snubbina devices or resilient <br />Table 13.6-1 Category = Vibration Isolated Corn <br />Se = 1.377 <br />S1 = 0.489 <br />Site Class (soil) = D <br />Risk Category = II Table 1.5-1 <br />Average roof height of structure, h = 0 ft <br />Height in structure of point of attachment of <br />component with respect to base, z = 0 ft <br />Component importance factor, IP = 1.0 Sect 13.1.3 <br />Operating weight of mechanical unit, Wp = 8200 lb. <br />Out ut <br />Site Coefficient, Fa = 1 Table 11-4.1 <br />SMs = 1.377 Eqn 11.4-1 <br />Ses = 0.918 Eqn 11.4-3 <br />z/h = 0 <br />Component amplification factor, a, = 2.5 <br />Component response modification factor, Rp = 2 <br />Component overstrength factor, Oa = 2 <br />Fp = 0.459 * WP, Eqn 13.3-1 <br />F,_= 1.469 * WP, Eqn 13.3-2 <br />FP_min = 0.275 * Wp, Eqn 13.3-3 <br />FP_horiz= 0.459 *Wp <br />FP_h,ra = 3763.8 lb (ULT) <br />FPven = */ 0.184 * W., Sect. 13.3.1 (apply concurrently with horizontal force) <br />FP,., =+/. 1508.8 lb (ULT), Sect 13.3.1 (apply concurrently with horizontal force) <br />NOTES: 1.) Anchors in concrete shall be designed in accordance with chapter 17 of ACI 318 <br />2.) Anchors in masonry shall be designed in accordance with ACI 530. Anchors shall be designed to be governed by the <br />tensile or shear strength of a ductile shear element. <br />EXCEPTION: Anchors shall be permitted to be designed so that either <br />1. The support or component that the anchor is connnecting to the structure undergoes ductile forces not <br />greater than the design strength of the anchors. <br />2. The anchors shall be designed to resist the load combinations in accordance with Section 12.4.3 <br />including Do as given in Tables 13.5-1 and 13.6-1. <br />3.) Post -installed anchors in concrete shall be prequalified for seismic applications in accordance with ACI 355.2 or other <br />approved qualification procedures. <br />Post -installed anchors in masonry shall be prequalified for seismic applications in accordance with approved <br />qualification procedures. <br />4.) Power actuated fasteners in concrete or steel shall not be used for sustained tension loads or for brace applications <br />in Seismic Design Categories D, E, or F unless approved for seismic loading. Power actuated fasteners in masonry <br />are not permitted unless approved for seismic loading. See Section 13.4.5 for exceptions. <br />5.) Friction clips in Seismic Design Categories D, E, or F shall not be used for supporting sustained loads in addition <br />to resisting seismic forces. <br />