My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6801 SEAWAY BLVD 2024-02-28
>
Address Records
>
SEAWAY BLVD
>
6801
>
6801 SEAWAY BLVD 2024-02-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/15/2024 9:53:42 AM
Creation date
2/11/2024 11:07:56 AM
Metadata
Fields
Template:
Address Document
Street Name
SEAWAY BLVD
Street Number
6801
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL LEGEND <br /> POWER RECEPTACLES&OUTLETS CONDUITS AND CIRCUITING ABBREVIATIONS <br /> 16 SINGLE RECEPTACLE WIRING CONCEALED IN CEILING OR WALL A(200A) (AFTER A NUMBER)=AMPS <br /> 1® DUPLEX RECEPTACLE WIRING CONCEALED UNDER FLOOR OR UNDERGROUND AF(200AF)(AFTER A NUMBER)=FUSE SIZE IN AMPS <br /> 0 DOUBLE DUPLEX RECEPTACLE - �CONDUIT HOME-RUN AFF ABOVE FINISHED FLOOR <br /> f8 DUPLEX GFCI RECEPTACLECONDUCTORS IN CONDUIT AHJ AUTHORITY HAVING JURISDICTION <br /> I® DOUBLE DUPLEX GFCI RECEPTACLE PHASE CONDUCTORS) AL ALUMINUM <br /> DUPLEX RECEPTACLE MOUNTED IN CEILING NEUTRAL CONDUCTOR ATS AUTOMATIC TRANSFER SWITCH <br /> GROUND CONDUCTOR BKR BREAKER TITAN ELECTRIC <br /> DOUBLE DUPLEX RECEPTACLE MOUNTED IN CEILING �I. GROUND WIRE C CONDUIT FULL SERVICE ELECTRICAL CONTRACTOR <br /> (@ DUPLEX RECEPTACLE MOUNTED+4'O.C.ABOVE COUNTER 12828 NORTHUP WAY,SUITE 205 <br /> OR BACLEX RECASH,EPTACLE <br /> WHEN PRESENT '0.C.NA CONDUIT BENDS TO CHANGE ELEVATION AT HIS POINT CKT CIRCUIT BELLEVUE,WA 98005 <br /> 1® DOUBLE DUPLEX RECEPTACLE MOUNTED+4"O.C.ABOVE CONDUIT STUB-UP CL CENTERLINE PH:206-633-2811 <br /> COUNTER OR BACKSPLASH,WHEN PRESENT(U.O.N.) -�,� CONDUIT BREAK <br /> CLG CEILING FA:206-374-2128 <br /> 10 DUPLEX GFCI RECEPTACLE MOUNTED+4"O.C.ABOVE CONDUIT CONTINUES ELSEWHERE(NOTED ON PLAN) CU COPPER <br /> DIA DIAMETER <br /> COUNTER OR EX GFCIL SH,RECEPTACLE <br /> WHEN PRESENT(+4*0) �>E CONDUIT TO BE REMOVED DISC DISCONNECT CASE�1 <br /> 1® DOUBLE DUPLEX GFCI RECEPTACLE MOUNTED+4"O.C.ABOVE MULTI-OUTLET ASSEMBLY(SEE NOTES ON PLAN) DISP DISPOSER /� S �-{ <br /> COUNTER OR BACKSPLASH,WHEN PRESENT(U.O.N.) 1,v L <br /> *WP GFCI RECEPTACLE WITH WEATHERPROOF WHILE-IN-USE COVER LIGHT FIXTURES&CONTROLS DW DISHWASHER <br /> E.C. ELECTRICAL CONTRACTOR PF ENGINEERING <br /> 10�@C FLOOR POKE-THRU WITH DEVICES SHOWN NOTE: LIGHTING FIXTURE SYMBOLS SHOW LENGTH,MOUNTING& ECB ENCLOSED CIRCUIT BREAKER <br /> EMERGENCY EGRESS INFORMATION ONLY.REFER TO M DUPLEX RECEPTACLE WITH 1/2 SWITCHED DESIGNATIONS&LIGHTING FIXTURE SCHEDULE FOR LAMP TYPE Sc (E) EXISTING(USED AS SYMBOL DESIGNATION) Consulting Electrical Engineers <br /> OTHER FIXTURE SPECIFICS. EMT ELECTRICAL METALLIC TUBING 19515 North Creek Parkway,Suite 302 <br /> 1® DOUBLE DUPLEX RECEPTACLE WITH 1/2 SWITCHED <br /> EXTG EXISTING(USED AS ABBREVIATION IN TEXT) Bothell,WA 98011 <br /> 1®T TAMPER RESISTANT RECEPTACLE <br /> Q RECESSED DOWNUGHT EV ELECTRIC VEHICLE(CHARGER) 425-402-9400 office@cascaseeng.com <br /> I® SINGLE SPECIAL PURPOSE RECEPTACLE FMP FIRE ALARM ANNUNCIATOR PANEL <br /> ® JUNCTION BOX WITH BLANK COVER CE ' PENDANT MOUNTED FIXTURE OR CHANDELIER FACP FIRE ALARM CONTROL PANEL <br /> 1OP FURNITURE SYSTEM POWER FEED,CONNECT CONDUCTORS Q Cy] SINGLE POINT SOURCE WALL MOUNTED FIXTURE FUR FLOOR <br /> TO FURNITURE SYSTEM FLEX CONDUIT PROVIDED BY SURFACE MOUNTED UNEAR FIXTURE(NARROW BODY) F.O.I.C. FURNISHED BY OTHERS,INSTALLED ELS, <br /> OTHERS.VERIFY REQUIREMENTS. BY ELECTRICAL CONTRACTOR GAP C <br /> TELE/COMMUNICATIONS SYSTEM DEVICES ® RECESSED LINEAR FIXTURE lot wASNYNOT <br /> FSD FIRE SMOKE DAMPER <br /> TELEPHONE ® PENDANT MOUNTED LINEAR FIXTURE <br /> GFCI GROUND FAULT CIRCUIT INTERRUPTER <br /> � WALL MOUNTED UNEAR FIXTUREW WALL MOUNTED TELEPHONE(VERIFY MOUNTING HEIGHT) GND GROUND <br /> SINGLE GANG TELEPHONE/DATA OPENING �a LINEAR STRIP FIXTURE HWT HOT WATER TANK OS 3- �4rp <br /> WALL MOUNTED STRIP FIXTURE kCMIL THOUSANDS OF CIRCULAR MILS �'MiRfRtNAU O`r <br /> Q WAP WIRELESS ACCESS POINT �� �10NALEN <br /> JUNCTION BOX&CONDUIT FOR FURNITURE SYSTEM =====o LINEAR UNDERCOUNTER FIXTURE KVA 1000 VOLT AMPERES <br /> TELE/DATA CONNECTIONS KW 1000 WATTS <br /> LED COVE OR UNDER COUNTER LIGHT(LENGTH AS SHOWN <br /> © DATA/COMM OUTLET(NUMBER INDICATES NUMBER OF ON PLAN) LCP LIGHTING CONTROL PANEL <br /> JACKS.'B'INDICATES BLANK PLATE) -Z—MO HACK UGHT(LENGTH AS SHOWN ON PLAN) LT LIGHT <br /> nB TELEPHONE TERMINAL BOARD-3/4"FIRE RESISTANT LTS(LTG) LIGHTS(UGHTING) SnoPUD SUBMITTAL <br /> PLYWOOD,8'HIGH x LENGTH SHOWN ON PLAN ® RECESSED UNEAR 2'X4'FIXTURE LV LOW VOLTAGE 05/05/2023 <br /> SERVICE GEAR-AS SHOWN ON PLANS ® RECESSED UNEAR 2'X2'FIXTURE MCB MAIN CIRCUIT BREAKER <br /> i CIRCUIT BREAKER PANELBOARD MECH MECHANICAL <br /> i EXISTING PANELBOARD TO REMAIN EMERGENCY EGRESS FIXTURES:SHADED FIXTURES REPRESENT A MLO MAIN LUGS ONLY <br /> CONNECTION TO EMERGENCY EGRESS UGHTING CIRCUIT VIA UL924 MSC MULTI-SCENE CONTROLLER <br /> o TERMINAL CABINET RELAY.DUAL CIRCUITS-NORMAL&EMERGENCY SHOWN ON PLAN N3R NEMA 3R <br /> O ASSHOWN WNON PLANS SWITCHBOARD OR MOTOR CONTROL CENTER,SIZE AS NORMAL#/EM/OR NORMAJ EM# NIC NOT IN CONTRACT <br /> AS SH <br /> DRY TYPE TRANSFORMER(SEE NOTES&RISER ® SURFACE UNEAR FIXTURE ON EMERGENCY EGRESS CIRCUIT NREC NON-RESIDENTIAL ENERGY CODE <br /> DIAGRAM FOR SIZE) ® RECESSED LINEAR FIXTURE ON EMERGENCY EGRESS CIRCUIT OS OCCUPANCY SENSOR <br /> ® TRANSFER SWITCH O• SINGLE POINT FIXTURE ON EMERGENCY EGRESS CIRCUIT PC PHOTOCELL <br /> GROUND BAR ® UNIVERSAL/CEILING MOUNTED EXIT SIGN PNL PANELBOARD <br /> ®® DIRECTIONAL EXIT SIGN(ARROWS INDICATE ONE OR REC RECEPTACLE(S) <br /> EQUIPMENT CONNECTIONS&CONTROLS TWO SIDES AND DIRECTION INDICATED) REF REFRIGERATOR <br /> ® EQUIPMENT CONNECTIONEMERGENCY EXIT SIGN WITH DUAL PATHWAY HEADS RQMTS REQUIREMENTS <br /> SCL SEATTLE CITY LIGHT <br /> 4 <br /> MOTOR CONNECTION tP DUAL HEAD EMERGENCY EGRESS FIXTURE SQ SQUARE <br /> 0 FAN CONNECTION SW SWITCH <br /> ELECTRIC WALL HEATER CONTROLLED BY WALL S SINGLE POLE LIGHT SWITCH TBD TO BE DETERMINED <br /> MOUNTED THERMOSTAT S' THREE POLE LIGHT SWITCH(NUMBER INDICATES NUMBER TrB TELEPHONE TERMINAL BOARD <br /> D4 ELECTRIC WALL HEATER WITH INTEGRAL THERMOSTAT OF POLES USED) TYP TYPICAL <br /> So DIMMER SWITCH <br /> ❑I DISCONNECT SWITCH Sts; OCCUPANCY SENSOR UGHT SWITCH UC UNDER COUNTER <br /> U.O.N. UNLESS OTHERWISE NOTED Project Title: <br /> QF I FUSED DISCONNECT SWITCH SVs VACANCY SENSOR LIGHT SWITCH UTIL UTILITY Renovations and <br /> ® MAGNETIC MOTOR STARTER SLV LOW VOLTAGE SWITCH CONTROLLED BY ROOM SENSOR VA VOLT AMPERES C <br /> EP COMBINATION STARTER AND DISCONNECT VFD VARIABLE FREQUENCY DRIVE Improvements for: <br /> SLyD UGHT SWITCH SUBSCRIPTS ARE AS FOLLOWS: <br /> B ENCLOSED CIRCUIT BREAKER nxi LV=LOW VOLTAGE,D=DIMMING VS VACANCY SENSOR <br /> D PUSHBUTTON SWITCH b=LOWER CASE LETTER CORRESPONDS TO LETTER AT SEAWAY <br /> FIXTURES TO ET CONTROLLED W WATTS <br /> S" MOTOR RATED SWITCH R1=RELAY#IN LIGHTING CONTROL PANEL WAP WIRELESS ACCESS POINT <br /> 1T WALL MOUNTED THERMOSTAT S#=SENSOR ZONE WC WATER COOLER <br /> ® OCCUPANCY SENSOR COMMERCIAL <br /> ® VACANCY SENSOR W/O WITHOUT <br /> NOTES AND MISCELLANEOUS SYMBOLS © PHOTOCELL UGHT SENSOR WP WEATHERPROOF CENTER <br /> 0 PHOTOCELL AIMED NORTH,MOUNTED ON BUILDING EXTERIOR XFMR TRANSFORMER <br /> THATE EXPLAINSENTIFIES A SPECIFIC ITEM ON A DRAWING- <br /> DETAILS OERUFEATURES OF THATI EMSET. 9' UGHT SWITCH WITH PILOT UGHT TEMP POWER <br /> Sx KEYED SWITCH <br /> D_3 MECHANICAL FLAG—DEFINES MECHANICAL EQUIPMENT AND ❑T LED TRANSFORMER—SHOWN AS NEEDED <br /> COORESPONDS TO DESIGNATIONS IN MECHANICAL PLANS AND <br /> SCHEDULES.COORESPONDS MECHANICAL CONNECTION <br /> SCHEDULE IN THE ELECTRICAL SET. NOTE:THESE STANDARDS APPLY ON ALL ELECTRICAL DRAWINGS 7007 SEAWAY BLVD. <br /> REVISION CLOUD AND FLAG-CLOUD SURROUNDS <br /> UNLESS NOTED OTHERWISE. EVERETT,WA 98203 <br /> INFORMATION THAT HAS BEEN REVISED, FLAG IDENTIFIES 4 SYMBOLS SHOWN ON PLANS IN STANDARD(HEAVY)1 THE REVISION IN WHICH THE CHANGES WERE MADE. 10 UNE WEIGHT ARE NEW OR RELOCATED WORK. <br /> O DETAIL NUMBER-APPEARS IN FRONT OF A TITLE ON Q SYMBOLS SHOWN IN LIGHT UNE WEIGHT OR <br /> DRAWINGS WITH MORE THAN ONE ILLUSTRATION. (E) DESIGNATED WITH(E)INDICATE EXISTING TO REMAIN. <br /> 3 IDENTIFICATION SYMBOL-CROSS REFERENCES INFORMATION Sheet Title: <br /> N ONE El.l IN ANOTHER�IN HEWITH AELECTRICDETAIL ALOSET)AND SHEET(BOTTOM ) �---�.� h'P` EMREMOVED OR EMOLISH D,13OLS SHOWN AS DASHED INDICATE ITEMS TO <br /> ELECTRICAL <br /> SYMBOL LEGEND, <br /> SHEET LIST <br /> Designed By: SH <br /> a Drawn By: SH <br /> m <br /> Project No: 23114 <br /> Date: 0510512023 <br /> N <br /> Sheet Number: <br /> ai <br /> m <br /> E0. 1 a <br />
The URL can be used to link to this page
Your browser does not support the video tag.