DONOR SITE INFORMATION <br />AV4 <br />Scope of Work: <br />To provide a custom designed solution to enhance the indoor Public Safety radio coverage with a <br />distributed antenna system to improve radio frequency signal loss caused by materials inside a building <br />A single donor antenna is mounted on the roof and pointed in the direction of the desired donor site <br />which is tuned to the desired frequency (See Design Notes for city specific requirements). The <br />frequencies are then carried through the 1/2" coaxial cable to the bi-directional amplifier (BDA). The <br />Class A BOA filters and amplifies the desired frequencies through 1/2" coaxial cable and indoor antennas <br />installed in strategic locations along with antennas to attain higher than the required -95 dBm over 95% <br />of the coverage area. <br />Code: <br />International Fire Code Section 510 <br />Applicable Provisions of NFPA 72, National Fire Alarm Signaling Code <br />Building Information: <br />Building Name: Walmart Everett <br />Address: 1605 SE Everett Mall Way, Everett, WA 98208 <br />Number of Floors: 1 <br />Total Square Feet: 91,419 <br />Design Notes: <br />Renovated Construction <br />Delivered Audio Quality (DAQ): <br />This radio coverage system provides a minimum quality level of 3.4 (DAQ "3.4") on each floor of the <br />building. <br />Supported Frequencies and Channels <br />This Design Supports: <br />806-824 MHz and 851-869 MHz <br />Snohomish County Frequencies as required <br />DAS System has 20 dB of isolation <br />Cable and Component Testing <br />Perform and record a sweep test of every cable section using an FOR sweep, by utilizing a 50 ohm load <br />terminator on the end of each cable. <br />Test all sections of cable with 2 connectors at common frequency bands for application (765-855 MHz <br />Etc. to cover 700/800 frequencies) <br />On test results no return loss at any connector along the cable segment shall be greater than 20 db. If <br />more a cable check needs to be done on the run for bends or tears if present replace bad section and re <br />-test cable. <br />General Notes and Procedures <br />1. Plans are not scaled and for outline only, unless otherwise noted. <br />2. Before submission of pre -construction drawings, the site will be visited and confirmed that the work <br />will be completed as presented before construction begins. <br />3. All equipment and materials will be installed in accordance with the manufacturer recommendations <br />unless indicated otherwise or where dictated local codes or regulations are needed. <br />4. All work performed and materials installed shall be in accordance with all applicable codes, <br />regulations and city ordinances, mechanical and electrical systems will be installed in accordance with all <br />city and state municipal and utility company specifications. <br />5. The project manager will supervise and direct the work with great attention to detail. Also be solely <br />responsible for all construction methods, techniques and procedures and for coordinating all portions of <br />the project with the site and landlord's authorized contact. <br />6. All construction shall be in accordance with the City of Everett municipal code and all adopted state <br />codes including addendums specifically set forth by the City of Everett. <br />7. Details are intended to show final result of design. Minor modifications may be required as project is <br />installed. <br />8. As a general rule, the project manager will keep the area clean, hazard free and dispose of garbage <br />properly. <br />9. Penetrations of roof membranes shall be patched/flashed and made watertight to protect the <br />property owner. <br />10. All circuits to be used to power the DAS shall be approved by the electrical engineer for 120V power <br />for the DAS and provide #2 bare copper ground at the head -end equipment location. <br />11. All wall mounted DAS equipment will be securely mounted on 3/4" backboard. <br />12. Attach J hooks to 1/2" cabling at 4' minimum sections when not installed in conduit or in supported <br />raceways. <br />13. Bend radius of 1/2" coax has a minimum of 10" <br />800 MHz (PUBLIC SAFETY) DONOR SITE INFORMATION <br />14. Provide fire stopped pathways between floors for vertical risers from equipment IDF closets to <br />antenna raceway. <br />15. Any or all sleeves or penetrations through a fire rated wall will be sealed with Hilti firestop assembly <br />or equivalent. <br />16. Antenna placement and cable routing is a design schematic only. The actual antenna install location <br />is to be within 10' of design drawing. <br />17. Secondary backup capable of 24 hour runtime per City of Everett Fire Code. <br />18. It is the installers responsibility to follow and abide by the code and policy requirements set forth by <br />the City of Everett fire codes. <br />19. The BDA is capable of providing a minimum of 12 channels in the 700/800 MHz band. <br />20. Frequencies used by City of Everett may change as a result of FCC order, or other operational <br />requirements of City of Everett. In the event of such frequency change and upon notification by the <br />municipality, the building owner shall modify or expand the DAS at their own expense. <br />SNOHOMISH COUNTY EMERGENCY RADIO SYSTEMS <br />REBANDED FREQUENCY PLAN <br />FASTSIMULCAST <br />NEW UPLINK NEW DOWNLINK REBANDED <br />CHI 808.9250 853.9250 YES <br />CH2 808.]SOO 153.111 YES <br />CH3 808.58]5 853.5875 YES <br />HI <br />CHI 11,1121 YES <br />CH] 808.6]SO 852.6]S. YES <br />CIA 80].9125 1111121 YES <br />CH9 80].9625 852.9625 YES <br />WP10911 / WPYQ414(WEST) <br />1A -76TH STREET <br />47-55-45.3 N, 122-14-20.4 W <br />187.5 M / 615 LT <br />1.2 - KINGSTON <br />47-08-29.0 N, 122-29-35.0 W <br />192.0 M / BID FT <br />1.3-BOTHELL <br />4]-4]-34.4 N, 122-14-20.5W <br />154.5M/507 FT <br />LA - MTLK TERRACE <br />4]-4]-50.3 N, 122-18-43.4 W <br />148.0 M / 486 Cr <br />1.5-GUNNYSACK <br />47-51-41.3 N, 122-17-01.4W <br />114.9M/3TY FT <br />IS CLEARVIEW <br />47-49-59.3 N, 122-07-26.4 W <br />137.1 M / 450 FT <br />1.] - RUCKER HILL <br />47-58-03.3 N, 122-13-24.4 W <br />184.] M / 606 FT <br />1.8-MARYWILLE <br />48-03-D8.3 N, 122-06-42AW <br />124.7M/409 FT <br />1.9 CLINTON <br />475]05.7 N, 1222157.OW <br />150.0 M/492 FT <br />WPYRBST / WPYRB]9 (EAST) <br />3.1-FIRETRAIL <br />48-0]-21.1 N, 122-14-36.2W <br />18GAM/ 591FT <br />3.2-CAMANO IS <br />48-13-35.0 N, 122-30-05.0 W <br />150.0 M / 5E0 FT <br />3.3-EAGLE RIDGE <br />48-12-09. 211-G1.DW <br />125.0 M/ 410 FT <br />3A-FRAILEY RIDGE <br />48-18-RED N, 121-59-47.0W <br />803.5 M/263]FT <br />5 GRANITEFALLS <br />4808-13.ON,1215853.OW <br />598.9 M/1.1 FT <br />6 KING LAKE <br />4]48-56.3 N, 1215532.4W <br />487.0 M/158FT <br />3.7 THREELAKES <br />475]17.0N,1215526.OW <br />362.1M/LIPS U <br />DARRINGTON AND INDEX IR <br />WP1OS1S (IN) <br />NEW UPLINK NEW DOWN LINK RERANDED <br />INDEX <br />47-5-0 N, 121-32-OS.0W <br />927.5 M/3043 FT <br />IR3 8GSEV5 853.6625 YES <br />IR2 807.]]SO 852.]]50 YES <br />DARRINGTON <br />48-14-56.3 N, 121-34-11.4W <br />91B.6 M/301]R <br />-.944(IR( <br />SKYKOMISH <br />UPLINK DOWNLINK MEAN- <br />MTSOBIESKI <br />47--.3 N, 121-19-42.3W <br />1333.E M/43]6 FT <br />IR1 810.7125 855.7125 NOT REQUIRED <br />IR2 811.2125 856.7325 NOT REQUIRED <br />IRS 811.4375 856.4375 NOT REQUIRED <br />IR4 811.2615 856.2625 NOT REQUIRED <br />5 811.9375 85ES375 NOT REQUIRED <br />IRS 812.2625 3­262S NOT REQUIRED <br />U15T UPDATED: AUG 5, 2015 <br />FILE: SERS ROD BDA_DAS REQ,DOCX <br />AW (1(91) <br />