My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1318 75TH ST SE 2024-03-01
>
Address Records
>
75TH ST SE
>
1318
>
1318 75TH ST SE 2024-03-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/1/2024 3:57:39 PM
Creation date
2/13/2024 11:03:33 AM
Metadata
Fields
Template:
Address Document
Street Name
75TH ST SE
Street Number
1318
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
312
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EGRESS W/ WINDOW WELL 3'x3' - �_\ <br />Cl <br />io <br />N <br />v <br />M <br />m <br />1 <br />A9 <br />29' - 6 1 /2" <br />EGRESS W/ WINDOW WELL 3'x3' <br />22' - 5 1 /2" <br />13'-107/ " <br />3 - 0" 3 - 0" <br />13'-107/8" <br />3 <br />BEDROOM <br />BEDROOM <br />164SF <br />164 SF <br />A9 <br />(S) <br />(S) <br />WF <br />WF <br />UTILITY <br />H19SF <br />(SC) <br />HEATPUMP HEATPUMPCONDESSOR <br />22'- 0 3/8" <br />(F) <br />W F <br />BATHROOM <br />BASEMENT <br />_ <br />54 SF <br />LIVING ROOM <br />397 SF <br />L-4-4-L L-4 <br />/I <br />I I I I II II I <br />10'-87/8" <br />10'-0" <br />31'-31/8" <br />7'- 0 1 /8" <br />13' 8 3/4" <br />30' - 6 5/8" <br />52' - 0" <br />BASEMENT <br />1/8" = 1'-0" <br />PERMT <br /># B2201-048 <br />A9 <br />EGRESS W/WINDOW W ELL 6'x3' <br />6 <br />A9 <br />BLUE MOON REALTY LLC <br />PROPOSED SFR <br />(F) <br />(S) <br />(SC) <br />50 CFM MIN EXHUAST FAN VENTTED TO EXTERIOR <br />SMOKE ALARM PER R314 <br />SMOKE ALARM/CO2 ALARM MIX HARDWIRED TO HOME WITH BACKUP BATTERY INTERCONNECTED. <br />(HHDD : HEAT RECTOR FOR THE GARAGE <br />WF : WHOLE HOUSE FAN. <br />WATER HEATER <br />NOTES: <br />1. TYPICAL EXTERIOR WALL: SIDING o/ INFILTRATION BARRIER o/ EXTERIOR SHEATHING PER STRUCTURAL PLANS / 2X6 STUDS @ 16" 0. C. w/ R-21 BATT INSULATION AND 1/ 2" MIN. <br />GWB AT INSIDE FACE. CONCRETE TO BE FOXBLOCKS 2 5/8" RIGID INSUL ON BOTH SIDE WITH 6" CONCRETE WALL. R-21 <br />2. TYPICAL INTERIOR WALL: SIDING o/ INFILTRATION BARRIER o/ EXTERIOR SHEATHING PER STRUCTURAL PLANS / 2X6 STUDS @ 16" 0. C. w/ R-21 BATT INSULATION AND 1/ 2" MIN. <br />GWB AT INSIDE FACE w/ P.V.A. PRIMER. <br />3. PROVIDE FIREBLOCKING ON ALL PLUMBING OPENING <br />4. PROVIDE SOLID BLOCKING ABOVE ANY SUPPORTS <br />5. PROVIDE FIREBLOCKING TO CUT OFF ALL CONCEALED HORIZONTAL AND VERTICLE DRAFT OPENING AND TO PROVIDE <br />EFFECTIVE FIRE BARRIER BETWEEN STORIES AND BETWEEN TOP AND ROOF SPACE <br />6. GARAGE DOOR: PROVIDE 13/8" SOLID CORE DOOR OR EQUIV. 20 MIN. RATED FIRE RATED DOOR BETWEEN HOUSE AND GARAGE. DOOR TO BE EQUIPPED WITH A SELF -CLOSING <br />DEVICE. ( R302.5. 1) <br />7. GARAGE WALL: SEPARATION FROM GARAGE AND RESIDENCE SHALL HAVE 1/ 2" GYPSUM BOARD APPLIED TO GARAGE SIDE. A 5/ 8" TYPE "X" GWB OR EQUIV. IS REQUIRED <br />BETWEEN THE GARAGE AND HABITABLE SPACE ABOVE THE GARAGE. ( R302.6 & TABLE 302.6) <br />&GUARDS SHALL BE REQUIRED AT OPEN SIDED WALKING SURFACES, PORCHES, STAIRS, RAMPS, BALCONIES AND LANDINGS LOCATED MORE THAN 30" ABOVE THE FLOOR OR <br />GRADE BELOW. GUARD SHALL NOT BE LESS THAN 36" IN HEIGHT. OPEN RAILS SHALL HAVE INTERMEDIATE RAILS SPACED SO THAT 4" SPHERE CANNOT PASS THROUGH. ( R312) <br />9.STAIR TREADS AND RISERS ( R311. 7): MAX. RISER HEIGHT SHALL BE 7 3/4". RISER SHALL BE MEASURED VERTICALLY BETWEEN LEADING EDGES OF THE ADJACENT TREADS. <br />DIFFERENCE IN RISER HEIGHTS SHALL NOT EXCEED 3/8". THE MIN, TREAD DEPTH SHALL BE 10". DIFFERENCE IN TREAD DEPTH SHALL NOT BE GREATER THAN 3/8". FIREBLOCK <br />STAIRS PER IRC 302. 11. ALL STAIRS TO BE PROVIDED WITH A LIGHT AND SWITCH AT TOP AND BOTTOM OF STAIRS ( R303.7). STAIR LANDINGS REQUIRED AT TOP AND BOTTOM <br />311.7. 6) <br />10. EGRESS WINDOWS: OPENINGS ARE REQUIRED FOR ALL SLEEPING ROOMS AND BASEMENTS. BOTTOM OF CLEAR OPENING IS NOT TO EXCEED 44" ABOVE FLOOR. OPENABLE AREA <br />IS 5. 7 SQ. FT. NET CLEAR MIN. EXCEPT 5.0 SQ. FT. IS ALLOWED FOR AN OPENING WITHIN 44" OF FINISHED GRADE. ( R310. 1) <br />11. DRYER: VENT TO OUTSIDE AND PER MANUFACTURER SPECICATIONS. DUCTS SHALL HAVE A SMOOTH INTERIOR FINISH AND CONSTRUCTED OF METAL. MAX. DUCT LENGTH PER <br />TABLE M1502.4.4. 1 OR M1502.4.4. 2. ( M1502) <br />12. ATTIC ACCESS: MIN. 22"X30" AND REQUIRED AT AREAS GREATER THAN 30 SQ. FT. AND VERTICAL HEIGHT OF 30" OR GREATER. ( R807. 1) SEE M1305. 1.3 FOR ADDITIONAL <br />REQUIREMENTS WHERE MECHANICAL EQUIPMENT IS LOCATED IN ATTIC. <br />13. TEMP. GLASS WINDOW <br />14. / 2" GWB UNDER STAIRWAY IN ENCLOSED SPACES <br />15. ALL BEDROOMS TO HAVE ELECTRIC RESISTANCE HEATING <br />16. BATHROOM WINDOW GLAZING AND STAIR WINDOW TO BE SAFTEY GLAZING (TEMPERED GLASS) PER R308.4.5 <br />17. WHOLE -HOUSE MECHANICAL VENTILATION SYSTEMS SHALL BE TESTED, BALANCED AND VERIFIED TO PROVIDE A FLOW RATE NOT LESS THAN THE MINIMUM REQUIRED BY <br />SECTIONS M1505.4.3 AND M1505.4.4. TESTING <br />SHALL BE PERFORMED ACCORDING TO THE VENTILATION EQUIPMENT MANUFACTURER'S INSTRUCTIONS, OR BY USING A FLOW HOOD, FLOW GRID, OR OTHER AIRFLOW MEASURING <br />DEVICE AT THE MECHANICAL VENTILATION FAN'S INLET TERMINALS, OUTLET TERMINALS OR GRILLES OR IN THE CONNECTED VENTILATION <br />DUCTS. WHERE REQUIRED BY THE BUILDING OFFICIAL, TESTING SHALL BE CONDUCTED BY AN APPROVED THIRD PARTY. A WRITTEN REPORT OF THE RESULTS OF THE TEST SHALL BE <br />SIGNED BY THE PARTY CONDUCTING THE TEST AND PROVIDED <br />TO THE BUILDING OFFICIAL AND BE POSTED IN THE DWELLING UNIT PER SECTION M1505.4.1.7. (M1505.4.1.6) <br />BASEMENT FLOOR PLAN <br />DATE: 4/25/2022 <br />A2 <br />coco <br />co <br />N <br />N <br />CD <br />N <br />N <br />T1p <br />
The URL can be used to link to this page
Your browser does not support the video tag.