My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1318 75TH ST SE 2024-03-01
>
Address Records
>
75TH ST SE
>
1318
>
1318 75TH ST SE 2024-03-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/1/2024 3:57:39 PM
Creation date
2/13/2024 11:03:33 AM
Metadata
Fields
Template:
Address Document
Street Name
75TH ST SE
Street Number
1318
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
312
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
o <br />r; m <br />0 <br />a. <br />A9 <br />12' - 5 1/2" <br />- 8" <br />22' - 11 1/2" <br />30'- 3 1/4" <br />v <br />_ <br />EGRESS <br />M <br />BEDROOM <br />0 Lo <br />123 SF <br />EGRESS <br />�p <br />N <br />T-0" <br />WF <br />MASTER BEDROOM <br />4 F <br />3 <br />Ro- <br />12' - 0" <br />_ <br />0o <br />M <br />o0 <br />i <br />� <br />o <br />� <br />SECOND FLOOR <br />- <br />A9 <br />0 <br />LIVING ROOM <br />- <br />rn <br />' <br />455 SF <br />�_ <br />0 <br />N <br />EGRESS <br />o <br />_ <br />DN <br />22' - <br />1 1/2" <br />BEDROOM <br />cV <br />- <br />123 SF 3, 0„ N <br />M <br />o <br />WF (S) (SC) <br />WF <br />(S) <br />WF <br />12'-0" <br />16'- 4 <br />1/2" <br />00 <br />BATHROOM <br />`o <br />oo <br />7 <br />72SF EGRESS <br />22 <br />CLOSET <br />BATHROOM (F) <br />C)(F) <br />0 <br />71 SF <br />77SF m <br />`o <br />12'_0„ <br />(o <br />10'-6' <br />11'-4" <br />oo <br />_ <br />0 <br />n <br />Li <br />rn <br />41 <br />in <br />SECOND FLOOR <br />1 /8" = 1'-0" <br />16'-73/8" <br />PERMT <br /># B2201-048 <br />I <br />7'- 10 3/4" 1 4'-7 3/8" I 10'- 9 1/2" <br />12'-2" <br />BLUE MOON REALTY LLC <br />PROPOSED SFR <br />(F) : 50 CFM MIN EXHUAST FAN VENTTED TO EXTERIOR <br />(S) : SMOKE ALARM PER R314 <br />(SC) : SMOKE ALARM/CO2 ALARM MIX HARDWIRED TO HOME WITH BACKUP BATTERY INTERCONNECTED. <br />(HD : HEAT RECTOR FOR THE GARAGE <br />WF : WHOLE HOUSE FAN. 80 CFM TO RUN EVERY 2 OF 4 HOURS <br />NOTES: <br />1. TYPICAL EXTERIOR WALL: SIDING o/ INFILTRATION BARRIER o/ EXTERIOR SHEATHING PER STRUCTURAL PLANS / 2X6 STUDS @ 16" 0. C. w/ R-21 BATT INSULATION AND 1/ 2" MIN. <br />GWB AT INSIDE FACE. <br />2. TYPICAL INTERIOR WALL: SIDING o/ INFILTRATION BARRIER o/ EXTERIOR SHEATHING PER STRUCTURAL PLANS/ 2X6 STUDS @ 16" 0. C. w/ R-21 BATT INSULATION AND 1/ 2" MIN. <br />GWB AT INSIDE FACE w/ P.V.A. PRIMER. <br />3. PROVIDE FIREBLOCKING ON ALL PLUMBING OPENING <br />4. PROVIDE SOLID BLOCKING ABOVE ANY SUPPORTS <br />5. PROVIDE FIREBLOCKING TO CUT OFF ALL CONCEALED HORIZONTAL AND VERTICLE DRAFT OPENING AND TO PROVIDE <br />EFFECTIVE FIRE BARRIER BETWEEN STORIES AND BETWEEN TOP AND ROOF SPACE <br />6. GARAGE DOOR: PROVIDE 13/8" SOLID CORE DOOR OR EQUIV. 20 MIN. RATED FIRE RATED DOOR BETWEEN HOUSE AND GARAGE. DOOR TO BE EQUIPPED WITH A SELF -CLOSING <br />DEVICE. ( R302.5. 1) <br />7. GARAGE WALL: SEPARATION FROM GARAGE AND RESIDENCE SHALL HAVE 1/ 2" GYPSUM BOARD APPLIED TO GARAGE SIDE. A S/ 8" TYPE "X" GWB OR EQUIV. IS REQUIRED <br />BETWEEN THE GARAGE AND HABITABLE SPACE ABOVE THE GARAGE. ( R302.6 & TABLE 302.6) <br />&GUARDS SHALL BE REQUIRED AT OPEN SIDED WALKING SURFACES, PORCHES, STAIRS, RAMPS, BALCONIES AND LANDINGS LOCATED MORE THAN 30" ABOVE THE FLOOR OR <br />GRADE BELOW. GUARD SHALL NOT BE LESS THAN 36" IN HEIGHT. OPEN RAILS SHALL HAVE INTERMEDIATE RAILS SPACED SO THAT A4" SPHERE CANNOT PASS THROUGH. ( R312) <br />9.STAIRTREADS AND RISERS ( R311. 7): MAX. RISER HEIGHT SHALL BE 7 3/4". RISER SHALL BE MEASURED VERTICALLY BETWEEN LEADING EDGES OF THE ADJACENT TREADS. <br />DIFFERENCE IN RISER HEIGHTS SHALL NOT EXCEED 3/8". THE MIN, TREAD DEPTH SHALL BE 10". DIFFERENCE IN TREAD DEPTH SHALL NOT BE GREATER THAN 3/8". FIREBLOCK <br />STAIRS PER IRC 302. 11. ALL STAIRS TO BE PROVIDED WITH A LIGHT AND SWITCH ATTOP AND BOTTOM OF STAIRS (R303.7). STAIR LANDINGS REQUIRED AT TOP AND BOTTOM <br />311. 7. 6) <br />10. EGRESS WINDOWS: OPENINGS ARE REQUIRED FOR ALL SLEEPING ROOMS AND BASEMENTS. BOTTOM OF CLEAR OPENING IS NOT TO EXCEED 44" ABOVE FLOOR. OPENABLE AREA <br />IS 5. 7 SQ. FT. NET CLEAR MIN. EXCEPT 5.0 SQ. FT. IS ALLOWED FOR AN OPENING WITHIN 44" OF FINISHED GRADE. ( R310. 1) <br />11. DRYER: VENT TO OUTSIDE AND PER MANUFACTURER SPECICATIONS. DUCTS SHALL HAVE A SMOOTH INTERIOR FINISH AND CONSTRUCTED OF METAL. MAX. DUCT LENGTH PER <br />TABLE M1502.4. 4. 1 OR M1502.4.4. 2. (M1502) <br />12. ATTIC ACCESS: MIN. 22"X30" AND REQUIRED ATAREAS GREATER THAN 30 SQ. FT. AND VERTICAL HEIGHT OF 30" OR GREATER. ( R807. 1) SEE M1305. 1. 3 FOR ADDITIONAL <br />REQUIREMENTS WHERE MECHANICAL EQUIPMENT IS LOCATED IN ATTIC. <br />13.TEMP. GLASS WINDOW <br />14. / 2" GWB UNDER STAIRWAY IN ENCLOSED SPACES <br />15. ALL BEDROOMS TO HAVE ELECTRIC RESISTANCE HEATING <br />16. BATHROOM WINDOW GLAZING AND STAIR WINDOW TO BE SAFTEY GLAZING (TEMPERED GLASS) PER R308.4.5 <br />17. WHOLE -HOUSE MECHANICAL VENTILATION SYSTEMS SHALL BE TESTED, BALANCED AND VERIFIED TO PROVIDE A FLOW RATE NOT LESS THAN THE MINIMUM REQUIRED BY SECTIONS <br />M 1505.4.3 AND M 1505.4.4. TESTING <br />SHALL BE PERFORMED ACCORDING TO THE VENTILATION EQUIPMENT MANUFACTURER'S INSTRUCTIONS, OR BY USING A FLOW HOOD, FLOW GRID, OR OTHER AIRFLOW MEASURING <br />DEVICE ATTHE MECHANICAL VENTILATION FAN'S INLETTERMINALS, <br />OUTLETTERMINALS OR GRILLES OR IN THE CONNECTED VENTILATION <br />DUCTS. WHERE REQUIRED BYTHE BUILDING OFFICIAL, TESTING SHALL BE CONDUCTED BY AN APPROVED THIRD PARTY. A WRITTEN REPORT OF THE RESULTS OF THE TEST SHALL BE <br />SIGNED BY THE PARTY CONDUCTING THE TEST AND PROVIDED <br />TO THE BUILDING OFFICIAL AND BE POSTED IN THE DWELLING UNIT PER SECTION M1505.4.1.7. (M1505.4.1.6) <br />SECOND FLOOR PLAN <br />DATE: 4/25/2022 <br />A4 <br />M <br />00 <br />N <br />N <br />O <br />N <br />N <br />ire <br />
The URL can be used to link to this page
Your browser does not support the video tag.